1. Einleitung
The ThruNite Archer 2A V3 is a compact and durable LED flashlight designed for versatile everyday use. Featuring a dual-switch interface, multiple brightness levels, and robust construction, it is suitable for various outdoor activities, emergency situations, and general illumination needs. This manual provides essential information for the proper setup, operation, and maintenance of your Archer 2A V3 flashlight.

Image 1: ThruNite Archer 2A V3 LED Flashlight, showcasing its sleek black aluminum body.
2. Packungsinhalt
Bitte prüfen Sie das Paket auf folgende Artikel:
- Archer 2A V3 flashlight x1
- Schlüsselband x1
- Pocket clip x1
- Ersatz-O-Ringe x2

Image 2: All items included in the ThruNite Archer 2A V3 package, laid out on a white background.
3. Spezifikationen
| Besonderheit | Detail |
|---|---|
| LED-Typ | XP-L2 LED |
| Maximale Leistung | 500 Lumen |
| Strahldistanz | 93 Meter |
| Stromquelle | 2 x AA batteries (Alkaline, not rechargeable) |
| Material | Aerospace-grade aluminum body with military-grade Type III hard-anodized anti-abrasive finish |
| Wasserbeständigkeit | IPX8 (2 Meter tauchfähig) |
| Schlagfestigkeit | 1 Meter |
| Maße | 6.1"T x 0.87"B x 0.87"H |
| Gewicht | 1.69 Unzen (ohne Batterien) |
The ThruNite Archer 2A V3 is designed for durability and performance, featuring a robust aluminum construction and an XP-L2 LED for efficient illumination.

Bild 3: Nahaufnahme view of the XP-L2 LED emitter, highlighting the orange peel reflector for a smooth beam.
4. Einrichtung
4.1 Einlegen der Batterie
The Archer 2A V3 requires two AA batteries (not included). To install the batteries:
- Schrauben Sie die Endkappe der Taschenlampe ab.
- Insert two AA batteries with the positive (+) end facing towards the head of the flashlight.
- Schrauben Sie die Endkappe wieder fest auf, um einen ordnungsgemäßen Kontakt und Wasserdichtigkeit zu gewährleisten.
Ensure the batteries are inserted correctly according to polarity markings to prevent damage to the flashlight.

Image 4: The tail cap of the ThruNite Archer 2A V3, which unscrews for battery access.
Video 1: A demonstration of battery installation and the robust construction of the tail cap switch, highlighting the heavy-duty spring and solid contact point. The video also shows the O-ring for IPX8 waterproofing.
5. Bedienungsanleitung
5.1 Ein-/Ausschalten
- Momentane Aktivierung: Press the tail cap halfway to momentarily activate the light.
- Konstant EIN/AUS: Fully click the tail switch to turn the light on or off.
5.2 Modusauswahl
When the light is on, use the side switch to cycle through the brightness modes:
- Zyklusmodi: Single press the side switch to rotate among Firefly, Low, Medium, and High modes.
- Stroboskop-Modus: Long press the side switch to activate Strobe mode. Single press the side switch again to exit Strobe mode and return to the previously used brightness level.
5.3 Mode Memory Function
The Archer 2A V3 features a mode memory function. It will remember the last used brightness mode (Firefly, Low, Medium, or High) when turned off and will activate in that mode when turned back on. Strobe mode is not memorized.
5.4 Output and Runtime (using 2x AA Alkaline batteries)
| Modus | Ausgabe | Laufzeit |
|---|---|---|
| Glühwürmchen | 0.2 Lumen | 15 Tage |
| Niedrig | 17 Lumen | 51 Stunden |
| Medium | 70 Lumen | 11 Stunden |
| Hoch | 500 Lumens (steps down to 280 Lumens after 3.3 minutes) | 3.3 Minutes + 2 Hours |
| Blitz | 400 Lumen | 2.25 Stunden |

Image 5: Illustration of the dual switch operation, showing the tail cap for ON/OFF and the side switch for mode changes.
Video 2: A short demonstration of the ThruNite Archer 2A V3's brightness levels and strobe function in a dark environment, showcasing its powerful output.
Video 3: Night shot footage demonstrating the beam throw and illumination capabilities of the Archer 2A V3 in various modes, highlighting its effectiveness in dark conditions.
6. Wartung
- Reinigung: Clean the threads and O-rings regularly with a clean cloth.
- Schmierung: Um die Wasserdichtigkeit zu erhalten, sollte regelmäßig eine dünne Schicht Silikonfett auf die O-Ringe aufgetragen werden.
- O-Ring-Austausch: Replace worn O-rings with the provided spare O-rings to ensure the IPX8 waterproof rating.
- Batteriepflege: Remove batteries from the flashlight if it will not be used for an extended period to prevent battery leakage and potential damage.
Video 4: Eine kurze Vorbemerkungview video demonstrating the IPX8 water resistance of the ThruNite Archer 2A V3 by submerging it in water while operating, confirming its waterproof capabilities.
7. Fehlerbehebung
- Licht geht nicht an:
- Prüfen Sie, ob die Batterien richtig eingelegt sind, mit dem Pluspol (+) zum Kopf zeigend.
- Stellen Sie sicher, dass die Endkappe fest aufgeschraubt ist.
- Replace batteries with fresh ones if they are depleted.
- Das Licht flackert oder schaltet sich unerwartet aus:
- Reinigen Sie die Batteriekontakte und das Gewinde mit einem sauberen Tuch.
- Stellen Sie sicher, dass die Endkappe vollständig festgezogen ist.
- Ladezustand der Batterie prüfen und ggf. austauschen.
8. Garantie und Support
ThruNite offers a limited warranty for its products. For detailed warranty information, product support, or any issues not covered in this manual, please contact ThruNite customer service directly. Contact information can typically be found on the official ThruNite webWebsite oder über Ihren Händler.
Kundendienst: Please do not hesitate to contact us if you encounter any further problems with our products.