This manual provides detailed instructions for the installation, operation, and maintenance of your ICO Bath K402W Kontour Hardwired Towel Warmer. Please read all instructions carefully before installation and use to ensure safe and proper functioning of the unit. Retain this manual for future reference.
2. Sicherheitshinweise
WARNUNG: Electrical installation should only be performed by a qualified electrician in accordance with all local and national electrical codes.
- Ensure the power supply is disconnected at the circuit breaker before beginning any installation or maintenance.
- Dieses Gerät ist nur für den Innenbereich vorgesehen.
- Do not immerse the towel warmer in water or other liquids.
- Do not use the towel warmer to dry items other than towels or garments suitable for drying on a heated surface.
- Keep children away from the towel warmer when it is in operation. The surface can become hot.
- Sorgen Sie für eine ordnungsgemäße Erdung gemäß den elektrischen Vorschriften.
3. Packungsinhalt
Vergewissern Sie sich vor Beginn der Installation, dass alle Komponenten vorhanden sind:
- ICO Bath K402W Kontour Towel Warmer Unit
- Mounting Hardware (screws, anchors, mounting brackets)
- Installationsvorlage
- Benutzerhandbuch (dieses Dokument)
4. Spezifikationen
| Besonderheit | Spezifikation |
|---|---|
| Modell | K402W |
| Abmessungen (H x B x T) | 40" x 18" x 4" |
| Leistungstyp | Festverdrahtet |
| Bandtage | 110 V |
| Wastage | 110 Watt |
| Material | Edelstahl |
| Beenden | Chrom |
| Anzahl der Balken | 9 |
| Artikelgewicht | 10 Pfund |
5. Einrichtung und Installation
Professional installation by a qualified electrician is recommended for this hardwired unit.
5.1. Planung des Installationsortes
- Choose a wall location that is structurally sound and can support the weight of the towel warmer and wet towels.
- Ensure the location is within reach of the intended electrical connection point.
- Maintain adequate clearance from other fixtures, walls, and flammable materials.
5.2. Mounting the Towel Warmer
- Bereiten Sie die Wand vor: Use the provided installation template to mark the drilling points for the mounting brackets on the wall. Ensure the template is level.
- Bohrlöcher: Bohren Sie an den markierten Stellen Vorbohrungen. Setzen Sie gegebenenfalls, je nach Wandmaterial, Dübel ein.
- Klammern anbringen: Befestigen Sie die Montagehalterungen mit den mitgelieferten Schrauben an der Wand.
- Position Towel Warmer: Carefully align the towel warmer with the mounting brackets and secure it in place.

Abbildung 1: Vorderseite view of the ICO Bath K402W Kontour Chrome Towel Warmer.
5.3. Elektrischer Anschluss (fest verdrahtet)
WICHTIG: Turn off power at the main circuit breaker before proceeding with electrical connections.
- Zugangsverkabelung: Locate the electrical junction box or wiring point behind the towel warmer.
- Kabel anschließen: Connect the towel warmer's electrical wires to the household wiring according to local electrical codes. Typically, this involves connecting the live (black) wire, neutral (white) wire, and ground (green or bare copper) wire.
- Sichere Verbindungen: Ensure all wire connections are secure using appropriate wire nuts or connectors.
- Verkabelung verbergen: Carefully push the wires back into the junction box and secure the cover plate. The design of the K402W allows for concealed screws for a clean aesthetic.
- Strom wiederherstellen: Once all connections are secure and the unit is mounted, restore power at the circuit breaker.

Figure 2: ICO Bath K402W Kontour Towel Warmer installed in a bathroom setting.
6. Bedienungsanleitung
The ICO Bath K402W Kontour Towel Warmer features an integrated On/Off switch for simple operation.
- Einschalten: Locate the On/Off switch on the towel warmer unit. Press the switch to the 'On' position. An indicator light (if present) may illuminate.
- Erhitzungszeit: Allow approximately 15-30 minutes for the towel warmer to reach its optimal operating temperature.
- Place Towels: Drape towels or garments over the bars. Do not overload the unit. Ensure air can circulate around the towels for efficient warming.
- Ausschalten: When not in use, or when towels are sufficiently warmed/dried, press the On/Off switch to the 'Off' position.
7. Wartung
Regelmäßige Reinigung und Wartung gewährleisten die Langlebigkeit und optimale Leistung Ihres Handtuchwärmers.
- Reinigung: Reinigen Sie die Oberfläche des Handtuchwärmers mit einem weichen,amp cloth. For stubborn spots, use a mild, non-abrasive cleaner. Avoid harsh chemicals, abrasive pads, or solvents, as these can damage the chrome finish.
- Do Not Polish: The chrome finish is designed to resist tarnishing. Avoid using metal polishes, which can alter the finish.
- Inspektion: Periodically inspect the electrical cord and connections for any signs of damage or wear. If damage is observed, discontinue use and contact a qualified electrician or ICO Bath customer support.
8. Fehlerbehebung
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Der Handtuchwärmer heizt nicht auf. | Keine Stromversorgung. Der Ein-/Ausschalter ist ausgeschaltet. Fehlerhafte Verkabelung. | Leistungsschalter prüfen. Ensure switch is in 'On' position. Kontaktieren Sie einen qualifizierten Elektriker. |
| Towel warmer is not getting hot enough. | Overloaded with too many towels. Ambient room temperature is too low. | Die Anzahl der Handtücher reduzieren. Bitten Sie um mehr Zeit zum Aufheizen. |
| Das Gerät macht ungewöhnliche Geräusche. | Internes Komponentenproblem. | Disconnect power and contact customer support. |
If you encounter issues not listed here, or if the suggested solutions do not resolve the problem, please contact ICO Bath customer support.
9. Garantieinformationen
The ICO Bath K402W Kontour Towel Warmer is covered under ICO Bath's limited warranty for parts. A 2-year commercial warranty is also provided. For specific terms and conditions of your warranty, please refer to the warranty documentation included with your purchase or visit the official ICO Bath webWebsite.
10. Unterstützung
For further assistance, technical support, or to inquire about replacement parts, please contact ICO Bath customer service:
- WebWebsite: www.icobath.com (Bitte überprüfen Sie die offizielle Website.) web(Die aktuellsten Kontaktinformationen finden Sie auf der Website.)
- Telefon: Refer to the ICO Bath webWebsite für regionale Kontaktnummern.