Fireangel CO-9X10

FireAngel CO-9X10 Kohlenmonoxidmelder – Benutzerhandbuch

Ihr Leitfaden für eine sichere und effektive Anwendung

Einführung

The FireAngel CO-9X10 is a certified carbon monoxide (CO) alarm designed to provide continuous monitoring for the presence of carbon monoxide gas. Featuring an advanced electrochemical sensor developed by FireAngel, this device ensures accurate detection of CO at low concentrations, offering maximum safety for your home or workplace. It comes with a built-in lithium battery designed for a 10-year lifespan, providing reliable protection without the need for battery replacement.

This manual provides essential information on the installation, operation, maintenance, and troubleshooting of your CO-9X10 alarm. Please read it thoroughly before installation and keep it for future reference.

FireAngel CO-9X10 Carbon Monoxide Alarm front view

Abbildung 1: Vorderseite view of the FireAngel CO-9X10 Carbon Monoxide Alarm. This image shows the main body of the alarm with the central test/reset button and the Power, Fault, and Alarm indicator lights.

Wichtige Sicherheitsinformationen

Carbon monoxide (CO) is a colorless, odorless, and tasteless gas that can be fatal. This alarm is designed to detect carbon monoxide gas from any source of combustion. It is not designed to detect smoke, fire, or other gases. For optimal safety, ensure proper ventilation and regular maintenance of fuel-burning appliances.

Packungsinhalt

Bitte überprüfen Sie den Packungsinhalt, um sicherzustellen, dass alle Artikel vorhanden sind:

Setup und Installation

Einen Standort auswählen

For optimal protection, install CO alarms in or near every room where fuel-burning appliances are located, and in sleeping areas. Consider placing an alarm on every level of your home. Avoid placing the alarm:

Montage des Alarms

The CO-9X10 can be wall-mounted or placed on a flat surface. For wall mounting:

  1. Select a suitable location, ideally at eye level or higher, but not directly on the ceiling unless specified by local regulations.
  2. Verwenden Sie die Montagehalterung als Schablone, um die Bohrlöcher an der Wand zu markieren.
  3. Bohren Sie zwei Löcher und setzen Sie die mitgelieferten Dübel ein.
  4. Screw the mounting bracket firmly to the wall.
  5. Attach the CO alarm to the mounting bracket by aligning the alarm with the bracket and twisting it clockwise until it clicks into place.
FireAngel CO-9X10 Carbon Monoxide Alarm with indicators

Abbildung 2: Detaillierte Vorderseite view of the FireAngel CO-9X10 showing the Power, Fault, and Alarm LED indicators. This view is helpful for understanding the device's status at a glance.

FireAngel CO-9X10 Carbon Monoxide Alarm side view

Abbildung 3: Seite view of the FireAngel CO-9X10 Carbon Monoxide Alarm, illustrating its compact profile and potential mounting features. This perspective can be useful for understanding how the device sits against a wall or on a surface.

Erstmalige Aktivierung

The CO-9X10 features a sealed-in lithium battery. The alarm will activate automatically when it is correctly attached to its mounting bracket. Upon activation, the green Power LED will flash once every 45 seconds, indicating normal operation.

Bedienungsanleitung

LED-Anzeigen

Testen des Alarms

It is crucial to test your CO alarm weekly to ensure it is functioning correctly.

  1. Press and hold the large "TEST/RESET" button on the front of the alarm.
  2. The alarm will sound a loud, distinctive pattern (typically 4 beeps, pause, 4 beeps) and the Red Alarm LED will flash.
  3. Release the button. The alarm should stop sounding, and the Red Alarm LED should stop flashing.
  4. If the alarm does not sound or the LEDs do not respond as described, refer to the Troubleshooting section.

Was tun, wenn der Alarm ertönt?

If your CO alarm sounds, it indicates the presence of carbon monoxide. Follow these steps immediately:

  1. Evacuate immediately: Move everyone, including pets, to fresh air outdoors or open doors/windows to ventilate the area.
  2. Do not re-enter the premises until the alarm has stopped and the area has been ventilated.
  3. Rufen Sie den Notdienst an: Contact your local emergency services (e.g., 999 in the UK) or a qualified gas technician to investigate the source of the CO.
  4. Identify and resolve the source: Do not use fuel-burning appliances until they have been checked by a professional.

Stille-Funktion

The alarm may have a silence feature for nuisance alarms (e.g., from temporary high CO levels during appliance startup). Pressing the "TEST/RESET" button during an alarm may silence it for a short period. However, if the CO level remains high, the alarm will reactivate. Only use the silence feature if you are certain it is a nuisance alarm and not a genuine CO threat.

Wartung

Regelmäßige Reinigung

Clean your CO alarm regularly to prevent dust and debris from affecting its performance. Use a soft, damp cloth to wipe the exterior. Do not use cleaning solvents or sprays directly on the alarm.

Battery Life and End-of-Life Signal

The FireAngel CO-9X10 is equipped with a sealed-in lithium battery designed to last for 10 years. When the alarm reaches the end of its operational life, it will emit a specific end-of-life signal (e.g., two short beeps every 45 seconds, accompanied by the Amber Fault LED flashing). When this occurs, the alarm needs to be replaced immediately.

Fehlerbehebung

ProblemMögliche UrsacheLösung
Alarm sounds continuously (Red LED flashing)High level of Carbon Monoxide detected.Sofort evakuieren. Call emergency services. Do not re-enter until cleared by professionals.
Amber Fault LED flashing / Alarm chirping intermittentlyLow battery or fault detected.The battery is sealed and cannot be replaced. If the alarm is chirping due to low battery or fault, it has reached its end-of-life or is malfunctioning. Ersetzen Sie den Alarm sofort.
Alarm does not sound when Test button is pressedAlarm malfunction or end-of-life.Ensure the alarm is properly mounted. If it still doesn't respond, the alarm is faulty or has reached its end-of-life. Ersetzen Sie den Alarm sofort.
Grüne Betriebs-LED blinkt nichtAlarm not activated or malfunction.Ensure the alarm is securely attached to its mounting bracket. If the issue persists, the alarm may be faulty. Ersetzen Sie den Wecker.

Technische Daten

BesonderheitDetail
ModellnummerCO-9X10
SensortypElektrochemisch
StromquelleSealed-in Lithium Battery (10-year life)
AlarmlautstärkeHörbar
Technische Daten11.2 x 3.5 x 7.2 cm
Artikelgewicht150 g
ZertifizierungenBSI EN50291-1:2010 and EN50291-2:2010 Certified
UPC816317003609

Garantie und Support

FireAngel products are manufactured to the highest standards. For specific warranty information, please refer to the documentation included with your purchase or visit the official FireAngel website. If you experience any issues with your CO-9X10 alarm or require technical assistance, please contact FireAngel customer support. Do not attempt to repair the alarm yourself.

Kontaktinformationen: Please refer to the FireAngel website or your purchase documentation for the most up-to-date contact details for customer support in your region.

Zugehörige Dokumente - CO-9X10

Vorview FireAngel CO-9X 7 Jahre Lebensdauer Kohlenmonoxidmelder Benutzerhandbuch
Ausführliches Benutzerhandbuch für den Kohlenmonoxid-Giftgasmelder FireAngel CO-9X mit 7-jähriger Lebensdauer. Erfahren Sie mehr über Installation, Betrieb, Wartung, Sicherheit und Fehlerbehebung.
Vorview FireAngel FA6813 Kohlenmonoxidmelder Benutzerhandbuch
Umfassendes Benutzerhandbuch für den Kohlenmonoxidmelder FireAngel FA6813 mit Informationen zu Installation, Betrieb, Wartung, Fehlerbehebung und Sicherheit.
Vorview FireAngel SCB10 Kombinierter Rauch- und Kohlenmonoxidmelder – Benutzerhandbuch
Benutzerhandbuch für den FireAngel SCB10, einen kombinierten Rauch- und Kohlenmonoxidmelder, mit umfassenden Anweisungen zu Installation, Betrieb, Wartung und Sicherheit für den privaten Gebrauch.
Vorview FireAngel FA6812/FA6813 Kohlenmonoxidmelder – Benutzerhandbuch
Benutzerhandbuch für die Kohlenmonoxid-Melder FireAngel FA6812 und FA6813, mit Anweisungen zur Installation, Bedienung, Sicherheit und Wartung.
Vorview FireAngel Multisensor Plus Benutzerhandbuch: Rauch-, Wärme- und CO-Melder
Ausführliches Benutzerhandbuch für FireAngel Multisensor Plus und Multisensor Plus Kitchen mit detaillierten Informationen zu Installation, Bedienung, Sicherheit, Fehlerbehebung und technischen Spezifikationen für die Rauch-, Wärme- und Kohlenmonoxiderkennung.
Vorview FireAngel CO-Melder FA3313, FA3322, FA3328, FA3820 Benutzerhandbuch
Umfassende Bedienungsanleitung für FireAngel Kohlenmonoxidmelder (Modelle FA3313, FA3322, FA3328, FA3820) mit Informationen zu Positionierung, Installation, CO-Alarmerkennung, Wartung, Statusanzeigen, Sleep-Easy-Funktion, LCD-Bildschirmanzeigen und technischen Daten. Enthält Informationen zu Garantie und Entsorgung.