1. Produktüberschreitungview
The FluidMaster 747 Floating Fill Valve is a high-quality, universal replacement valve designed for efficient and quiet water refilling in both concealed and exposed plastic and ceramic toilet cisterns. Engineered for reliability and ease of installation, this valve is suitable for a wide range of plumbing systems, operating effectively under both high and low water pressure conditions. Its self-cleaning mechanism ensures long-term performance with minimal maintenance.

FluidMaster 747 Floating Fill Valve
2. Hauptmerkmale
- Einstellbare Höhe: The valve height can be adjusted from 230 mm to 355 mm, allowing for flexible installation in various cistern sizes.
- Vielseitige Kompatibilität: Suitable for both high and low water pressure systems, functioning reliably from 0.5 bar minimum to 10 bar maximum pressure.
- Extrem leiser Betrieb: Classified as Noise Class 1, operating at ≤20 dB(A) for a silent refill experience.
- Fast Filling: Optimized mechanics ensure rapid refilling of the toilet cistern.
- Self-Cleaning Mechanism: Features a unique mechanism for reduced maintenance and prolonged lifespan.
- Einfache Installation: Designed for quick and straightforward mounting.
- Durable Brass Connector: Equipped with a G 3/8" x 35 mm brass connector for a robust and secure connection.
- Kompaktes Design: Efficiently designed to fit into various cistern configurations.

Detailed diagram of the FluidMaster 747 valve, showing key components like the brass shank, water level adjusting screw, and diffuser, along with dimensions.
3. Einrichtung und Installation
Follow these steps for proper installation of your FluidMaster 747 Fill Valve:
- Wasserzufuhr abstellen: Locate the water shut-off valve for your toilet, usually near the base, and turn it clockwise until the water flow stops.
- Leerer Zisternenraum: Flush the toilet to drain the water from the cistern. Hold the flush handle down to ensure as much water as possible is removed.
- Altes Ventil entfernen (falls zutreffend): Disconnect the water supply line from the old fill valve. Unscrew the locknut from underneath the cistern that secures the old valve, then remove the old valve.
- Insert New Valve: Place the FluidMaster 747 fill valve into the hole at the bottom of the cistern. Ensure the shank is properly seated.
- Sicheres Ventil: From underneath the cistern, thread the provided locknut onto the valve shank and tighten it by hand. Do not overtighten, as this can damage the cistern or valve.
- Wasserversorgung anschließen: Attach the water supply line to the brass connector (G 3/8" x 35 mm) at the base of the new fill valve. Tighten securely by hand, then use a wrench for a final quarter-turn, being careful not to overtighten.
- Höhe anpassen: The valve's height can be adjusted by twisting the upper section or using the water level adjusting screw (refer to product diagrams). Adjust the valve so that the critical level mark is above the overflow pipe.
- Wasserversorgung wiederherstellen: Slowly turn the water shut-off valve counter-clockwise to restore water flow to the cistern. Check for any leaks around the connections.
- Wasserstand anpassen: Allow the cistern to fill. If the water level is too high or too low, fine-tune the float mechanism using the water level adjusting screw until the desired water level is achieved (typically about 1 inch below the top of the overflow pipe).

Visual guide for installing the FluidMaster 747 valve, showing key installation steps.

Illustration demonstrating the FluidMaster 747 valve's compatibility with various toilet cisterns and a list of included components.
4. Bedienungsanleitung
The FluidMaster 747 Floating Fill Valve operates automatically. Once installed and the water supply is turned on, the valve will sense the water level in the cistern. After each flush, as the water level drops, the float mechanism will activate the valve, allowing water to refill the cistern to the pre-set level. The valve will then shut off, maintaining the desired water volume for the next flush.
Ensure the water level is adjusted correctly during installation for optimal flushing performance and water conservation.
5. Wartung
The FluidMaster 747 valve features a self-cleaning mechanism designed to minimize the need for frequent maintenance. However, periodic checks can help ensure its longevity and efficient operation:
- Regelmäßige Inspektion: Periodically inspect the valve for any signs of wear, debris, or mineral buildup, especially in areas with hard water.
- Reinigung: If you notice slow filling or reduced performance, turn off the water supply and gently clean any visible debris from the valve's inlet screen or float mechanism.
- Vermeiden Sie scharfe Reinigungsmittel: WARNUNG: Do not use in-tank, drop-in toilet bowl cleaners containing bleach or chlorine. Use of such products can result in damage to tank components and property, and may void the Fluidmaster warranty. Always use quality Fluidmaster parts when installing or repairing.
6. Fehlerbehebung
If you encounter issues with your FluidMaster 747 Fill Valve, refer to the following common problems and solutions:
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Cistern fills slowly or not at all | Low water pressure; clogged inlet screen; kinked supply line. | Check household water pressure. Turn off water, disconnect supply line, clean inlet screen. Straighten supply line. |
| Valve does not shut off / Water constantly runs | Water level set too high; float mechanism obstructed; faulty flush valve/flapper. | Adjust water level lower using the adjusting screw. Ensure float moves freely. Inspect and replace flush valve/flapper if necessary. |
| Lecks an den Verbindungen | Loose connections; worn washers/gaskets. | Ensure all connections are hand-tightened, then a quarter-turn with a wrench. Replace any damaged washers or gaskets. |
7. Spezifikationen
| Modellnummer | 747E-036-P20 |
| Abmessungen (L x B x H) | 7 x 8.5 x 30 cm (Product); Adjustable height 230 mm to 355 mm |
| Gewicht | 270 Gramm |
| Anschlussmaterial | Messing |
| Steckergröße | G 3/8" x 35 mm |
| Maximale Betriebstemperatur | 30 °C |
| Maximaler Druck | 10 bar |
| Mindestdruck | 0.5 bar |
| Geräuschklasse | Group I, ≤20 dB(A) |
| Zertifizierung | CE |
8. Garantie und Support
Specific warranty details for this product are not provided in the available information. For warranty claims, technical support, or further inquiries, please contact Fluidmaster customer service directly or visit their official webWebsite.
Offiziell WebWebsite: www.fluidmaster.com