Einführung
This manual provides essential information for the safe and efficient operation, maintenance, and troubleshooting of your Greenworks G24WDV 24V Wet/Dry Shop Vacuum. Please read it thoroughly before first use and keep it for future reference.
The Greenworks G24WDV is a versatile 24V cordless wet/dry shop vacuum designed for both wet and dry cleaning tasks. Its compact and portable design makes it ideal for use in various environments, including garages, cars, kitchens, and workshops. The vacuum features two filtration systems for enhanced particle capture and offers two speed levels for optimized performance. It is part of the Greenworks 24V battery system, allowing for battery interchangeability with other Greenworks 24V tools.
Allgemeine Sicherheitshinweise
WARNUNG: Lesen Sie alle Sicherheitswarnungen und Anweisungen. Bei Nichtbeachtung der Warnungen und Anweisungen besteht die Gefahr eines Stromschlags, Brands und/oder schwerer Verletzungen.
- Tragen Sie immer geeignete persönliche Schutzausrüstung (PSA) wie Schutzbrille, Gehörschutz und Handschuhe.
- Do not operate the vacuum in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust.
- Keep children and bystanders away while operating the vacuum. Distractions can cause you to lose control.
- Do not vacuum toxic, carcinogenic, or other hazardous materials such as asbestos, arsenic, barium, beryllium, lead, pesticides, or other health-endangering materials.
- Do not vacuum hot ashes, charcoal, or other hot materials.
- Ensure the battery pack is securely installed before operation and removed before making any adjustments, changing accessories, or storing the tool.
- Verwenden Sie ausschließlich Greenworks 24V-Akkus und -Ladegeräte.
- Setzen Sie den Staubsauger weder Regen noch Nässe aus. Eindringendes Wasser erhöht das Risiko eines Stromschlags.
- Maintain the vacuum with care. Check for misalignment or binding of moving parts, breakage of parts, and any other condition that may affect the vacuum's operation. If damaged, have the vacuum repaired before use.
Produkt überview
Familiarize yourself with the components of your Greenworks G24WDV Wet/Dry Shop Vacuum.

Abbildung 1: Haupt view of the Greenworks G24WDV 24V Wet/Dry Shop Vacuum.
Hauptmerkmale:
- Kabelloser Betrieb: Powered by Greenworks 24V batteries for freedom of movement.
- Nass- und Trockentauglichkeit: Effectively cleans both solid debris and liquid spills.
- Kompaktes Design: Tool box design for easy transport and storage (Size: 495mm L * 478mm W * 276mm H).
- Doppeltes Filtersystem: Equipped with two filters, including a washable and reusable HEPA filter, to capture fine particles.
- Gebläsefunktion: Easily converts to a blower for clearing dust from corners and hard-to-reach areas.
- Zwei Geschwindigkeitsstufen: Adjustable suction power for different cleaning needs.
- Tankinhalt 11 Liter: Sufficient capacity for various cleaning tasks.
Aufstellen
1. Einlegen der Batterie
The Greenworks G24WDV operates with a 24V Greenworks battery (not included in all sets). Ensure the battery is fully charged before use.
- Richten Sie den Akku an der Akkubuchse des Staubsaugers aus.
- Slide the battery pack into the port until it clicks into place. Ensure it is securely latched.
- Zum Entnehmen den Batterieentriegelungsknopf drücken und die Batterie herausschieben.
2. Attaching Hose and Accessories
The vacuum comes with a flexible hose and various attachments for different cleaning applications.

Figure 2: Attaching the vacuum hose.
- Insert the end of the flexible hose into the suction port on the front of the vacuum until it is firmly seated.
- Select the desired cleaning attachment (e.g., crevice tool, wide nozzle) and attach it to the other end of the hose.
- For the blower function, attach the hose to the blower port located on the rear of the vacuum.
3. Filterinstallation
The vacuum uses a dual filtration system, including a HEPA filter, for optimal performance.

Figure 3: Washable and reusable HEPA filter system.
- Öffnen Sie den Deckel des Staubsaugers, indem Sie ihn lösen.asing die Riegel.
- Ensure the HEPA filter is correctly seated over the filter cage.
- For dry vacuuming, ensure the dry filter is in place. For wet vacuuming, remove the dry filter and ensure the foam filter (if applicable) is installed.
- Close the lid securely with the latches.
Bedienungsanleitung
1. Nasssaugen
When vacuuming liquids, ensure the dry filter is removed and the foam filter (if provided) is installed. Do not overfill the tank.

Figure 4: Using the vacuum for wet cleaning in a car.
- Prepare the vacuum for wet use as described in the filter installation section.
- Schalten Sie das Vakuum mit dem Netzschalter ein.
- Richten Sie die Düse über die ausgelaufene Flüssigkeit. Das Vakuumgerät schaltet sich automatisch ab, sobald der Tank voll ist.
- Empty the tank immediately after wet vacuuming to prevent damage.
2. Trockensaugen
For dry debris, ensure the HEPA filter and dry filter are correctly installed.

Figure 5: Dry vacuuming a floor.
- Ensure the vacuum is set up for dry use.
- Schalten Sie den Staubsauger ein.
- Move the nozzle over the dry debris to collect it.
3. Gebläsefunktion
The vacuum can be converted into a blower for clearing light debris.

Figure 6: Using the blower function to clear sawdust.
- Attach the hose to the blower port on the rear of the vacuum.
- Schalten Sie den Staubsauger ein.
- Direct the airflow to clear dust and light debris from surfaces.
4. Geschwindigkeitseinstellungen
The vacuum offers two speed levels. Use the control switch to select the appropriate speed for your task. Higher speed provides stronger suction for tougher jobs, while lower speed conserves battery life for lighter cleaning.
5. Den Tank leeren
Regularly empty the tank to maintain optimal suction and prevent overflow during wet vacuuming.
- Schalten Sie den Staubsauger aus und entfernen Sie den Akku.
- Release the latches and remove the lid assembly.
- Carefully pour out the collected debris or liquid into an appropriate disposal container.
- Clean the inside of the tank if necessary before reassembling.
Wartung
Proper maintenance ensures the longevity and performance of your vacuum.
1. Reinigung des Filters
Der HEPA-Filter ist waschbar und wiederverwendbar. Reinigen Sie ihn regelmäßig, um die Saugleistung zu erhalten.

Figure 7: Washing the HEPA filter.
- Schalten Sie den Staubsauger aus und entfernen Sie den Akku.
- Remove the lid assembly and carefully detach the HEPA filter.
- Spülen Sie den Filter unter fließendem Wasser ab, bis er sauber ist. Verwenden Sie kein heißes Wasser oder Reinigungsmittel.
- Allow the filter to air dry completely before reinstalling. Do not use a heat source to dry.
- For foam filters used in wet applications, rinse and air dry as well.
2. Reinigung des Tanks
After each use, especially after wet vacuuming, clean the tank to prevent odors and mold growth.
- Empty the tank as described in the operating instructions.
- Wipe the inside of the tank with a damp cloth. For stubborn residue, use mild soap and water, then rinse thoroughly.
- Allow the tank to air dry completely before reassembling the vacuum.
3. Allgemeine Reinigung
Wischen Sie die Außenseite des Staubsaugers mit Ad abamp cloth. Do not use harsh chemicals or abrasive cleaners. Check the hose and attachments for blockages and clear them as needed.
Fehlerbehebung
This section addresses common issues you might encounter with your Greenworks G24WDV vacuum.
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Der Staubsauger lässt sich nicht einschalten. | Batterie nicht richtig eingesetzt oder entladen. | Stellen Sie sicher, dass der Akku vollständig geladen und richtig eingelegt ist. |
| Geringe Saugleistung. | Clogged filter, full tank, or hose/nozzle blockage. | Clean or replace filter. Empty tank. Check and clear any blockages in hose or attachments. |
| Der Motor läuft, aber es entsteht kein Sog. | Schlauch nicht richtig angeschlossen oder stark verstopft. | Ensure hose is securely attached to the suction port. Check for and remove any large blockages. |
| Beim Nasssaugen tritt Wasser aus. | Tank is full or lid is not sealed properly. | Empty the tank. Ensure the lid is securely latched and the gasket is properly seated. |
Technische Daten
- Modellnummer: 01-000004700407
- Produktabmessungen: 50 x 35 x 29.5 cm
- Product Weight (without packaging): 6.5 kg
- Kapazität: 11 Liter
- Energiequelle: Batterie (24V)
- Filtertyp: HEPA-Filter
- Besondere Merkmale: Kompakt, tragbar
- Luftvolumen: 62 CFM
- Geschwindigkeitsstufen: 2
Garantie und Support
For warranty information, technical support, or to purchase replacement parts, please refer to the official Greenworks webBesuchen Sie die Website oder kontaktieren Sie den Kundenservice. Bewahren Sie Ihren Kaufbeleg als Kaufnachweis für Garantieansprüche auf.