Xetron STC-1000Pro

Xetron STC-1000Pro Digital Temperature Controller User Manual

Model: STC-1000Pro | Brand: Xetron

1. Einleitung

The Xetron STC-1000Pro is a versatile digital temperature controller designed for precise temperature management in various environments. It features dual outlets for simultaneous heating and cooling control, a wide temperature range, and user-friendly operation. This manual provides detailed instructions for setting up, operating, and maintaining your device.

Xetron STC-1000Pro Digital Temperature Controller with power cord, sensor, and dual outlets

Figure 1: Xetron STC-1000Pro Digital Temperature Controller. This image displays the main unit with its digital display, control buttons, power cord, temperature sensor, and the dual-outlet power strip for heating and cooling devices.

Anwendungen

The STC-1000Pro is suitable for a wide range of applications requiring accurate temperature control, including:

Various applications of the Xetron STC-1000Pro controller

Figure 2: Common applications for the Xetron STC-1000Pro. This image illustrates the controller's use in home brewing, incubators, aquariums, and flower cultivation, highlighting its versatility.

2. Hauptmerkmale

Xetron STC-1000Pro maintaining temperature range

Figure 3: Temperature control range of the Xetron STC-1000Pro. This image highlights the controller's ability to maintain temperatures within a desired range of -40 to 230 ℉ using both cooling and heating devices.

Xetron STC-1000Pro large screen display with dimensions

Figure 4: Large screen display of the Xetron STC-1000Pro. The image shows the display dimensions and labels for PV (Present Value), SV (Set Value), Csp (Cooling Start Point), and Hsp (Heating Start Point), indicating ℃/℉ switchability.

Xetron STC-1000Pro visual and audible alerts

Figure 5: Visual and audible alert features. This image illustrates the double alarm and delay protection functionalities of the controller, enhancing safety and monitoring.

Xetron STC-1000Pro safety certifications

Figure 6: Safety and quality certifications. The image highlights the V-0 flame-retardant ABS material and compliance with CE, FCC, and RoHS standards, ensuring product safety.

Xetron STC-1000Pro IP65 waterproof probe

Figure 7: IP65 waterproof features. This image demonstrates the waterproof capability of the temperature probe, which can be immersed in fresh water, and the internal rubber ring for main unit protection.

3. Einrichtungsanweisungen

  1. Packen Sie das Gerät aus: Carefully remove the Xetron STC-1000Pro controller and its components from the packaging.
  2. Schließen Sie den Sensor an: Ensure the temperature sensor is fully inserted into its dedicated port on the side of the controller. A loose connection can lead to "ERR" display.
  3. Positionieren Sie den Sensor: Place the temperature probe in the environment where temperature monitoring and control are required. Ensure it is not directly exposed to heating or cooling elements to get an accurate reading.
  4. Heiz-/Kühlgeräte anschließen:
    • Plug your heating device (e.g., heat lamp, heating mat) into the socket labeled "HEATING".
    • Plug your cooling device (e.g., fan, chiller) into the socket labeled "COOLING".

    Wichtig: The maximum output for each socket is 10A at 240VAC. Do not connect high-power equipment exceeding these limits.

  5. Einschalten: Plug the controller's main power cord into a standard 230V AC power outlet. The display will illuminate, showing the current temperature (PV) and other settings.
Xetron STC-1000Pro plug and play setup

Figure 8: Plug-and-play setup of the Xetron STC-1000Pro. This image demonstrates the simplicity of connecting the controller, showing it mounted on a wall next to a terrarium, with heating/cooling devices plugged in.

4. Bedienungsanleitung

The STC-1000Pro features a simple 3-button interface: SATZ, AUF (▲), Und UNTEN (▼).

4.1 Anzeige überview

4.2 Einstellen der Zieltemperatur (SV)

  1. Drücken Sie die SATZ button once. The SV value will flash.
  2. Verwenden Sie die AUF (▲) or UNTEN (▼) Tasten zur Einstellung der Zieltemperatur.
  3. Drücken SATZ Um die Einstellung zu bestätigen und zu speichern, klicken Sie erneut oder warten Sie einige Sekunden, bis sie automatisch gespeichert wird.

4.3 Erweiterte Parametereinstellungen

Um auf die erweiterten Einstellungen zuzugreifen, halten Sie die Taste gedrückt. SATZ button for approximately 3 seconds until the display changes to show parameter codes.

Xetron STC-1000Pro parameter setting diagram

Figure 9: Diagram illustrating parameter settings. This image shows the relationship between TS (Temperature Set-point), CD (Cooling Differential), HD (Heating Differential), Csp (Cooling Start Point), and Hsp (Heating Start Point).

Verwenden Sie die AUF (▲) or UNTEN (▼) buttons to navigate through the parameters. Press SATZ to enter a parameter's value, then use AUF (▲) or UNTEN (▼) sich anzupassen und SATZ wieder zu speichern.

Table 1: Advanced Parameters
ParameterBeschreibungReichweiteStandard
TS (Temperature Set-point)The desired target temperature (same as SV).-40 bis 110 ℃ / -40 bis 230 ℉Variiert
CD (Cooling Differential)The difference between the cooling start point (Csp) and the set temperature (TS). Cooling activates when PV ≥ TS + CD.0.1 to 30 ℃ / 0.1 to 54 ℉2 ℃ / 3.6 ℉
HD (Heating Differential)The difference between the heating start point (Hsp) and the set temperature (TS). Heating activates when PV ≤ TS - HD.0.1 to 30 ℃ / 0.1 to 54 ℉2 ℃ / 3.6 ℉
PT (Protection Time)Compressor delay protection time (in minutes) for cooling mode only. Prevents frequent compressor cycling.0 bis 10 Minuten3 Мinuten
CA (Temperature Calibration)Adjusts the temperature reading to match an external reference thermometer.-10 bis 10 ℃ / -18 bis 18 ℉0 ℃ / 0 ℉
CF (Unit Switch)Switches between Celsius (℃) and Fahrenheit (℉).C / FC
HA (High Alarm)Sets the upper temperature limit for the alarm.TS to 110 ℃ / TS to 230 ℉110 ℃ / 230 ℉
LA (Low Alarm)Sets the lower temperature limit for the alarm.-40 ℃ / -40 ℉ to TS-40 ℃ / -40 ℉

After adjusting parameters, press and hold SATZ again for 3 seconds to exit the advanced settings menu and return to normal operation.

5. Wartung

6. Fehlerbehebung

Tabelle 2: Anleitung zur Fehlerbehebung
ProblemMögliche UrsacheLösung
Auf dem Bildschirm wird „ERR“ angezeigtTemperature sensor not fully inserted or damaged; temperature exceeds measurement range.Ensure the sensor is fully inserted into its port. If the issue persists, the sensor may be faulty and require replacement. If the temperature is outside the -40 to 110 ℃ range, the controller will display "ERR".
Alarm sounds and bell icon appearsCurrent temperature (PV) has exceeded the set high alarm (HA) or fallen below the low alarm (LA) threshold.Check the environmental conditions. Adjust HA/LA settings if necessary. The controller will disable all outputs in fault alarm mode to protect equipment.
Heating/Cooling device not activatingIncorrect temperature settings (TS, CD, HD); compressor delay protection (PT) active; device not properly plugged in; device malfunction.Verify TS, CD, and HD settings. Wait for the PT delay to expire in cooling mode. Ensure devices are securely plugged into the correct outlets. Test heating/cooling devices independently.
Ungenaue TemperaturanzeigeSensor placement; temperature calibration (CA) offset.Relocate the sensor to a more representative area. Use the CA parameter to calibrate the reading against a known accurate thermometer.

7. Spezifikationen

Tabelle 3: Produktspezifikationen
BesonderheitDetail
ModellnummerXT-STC1000Pro-01US
MarkeXetron
Bandtage230V AC (Note: Product description mentions 230V, specifications mention 110V. User should verify their specific model's voltage Anforderungen.)
Max Ausgangsstrom10A pro Steckdose
Temperaturregelbereich-40 ℃ bis 110 ℃ (-40 ℉ bis 230 ℉)
Temperaturgenauigkeit±1 ℃ / ±2 ℉
AnzeigetypOLED
MaterialFlame-retardant ABS Plastic
Produktabmessungen (L x B x H)20 x 15 x 6 cm
Gewicht400 Gramm
BetriebstemperaturBis zu 110 °C
Im Lieferumfang enthaltene Komponenten1x Temperature Controller

8. Sicherheitshinweise und Vorsichtsmaßnahmen

9. Support und Kontaktinformationen

For any questions, technical assistance, or customer service inquiries regarding your Xetron STC-1000Pro Digital Temperature Controller, please contact Xetron customer support. We are committed to providing satisfactory customer service.

Bitte beachten Sie die Produktverpackung oder die Angaben des Händlers. webDie aktuellsten Kontaktdaten finden Sie auf der Website.

Zugehörige Dokumente - STC-1000Pro

Vorview Benutzerhandbuch für die Smart-Temperaturregler-Serie Xetron STC-1000Pro TH
Umfassendes Benutzerhandbuch für die Xetron STC-1000Pro TH Smart Temperature Controller-Serie mit detaillierten Informationen zu Funktionen, Betrieb, Installation und technischen Daten für eine präzise Temperatur- und Feuchtigkeitsregelung.
Vorview Xetron STC-1000Pro Smart Temperature Controller Benutzerhandbuch
Benutzerhandbuch für den intelligenten digitalen Temperaturregler Xetron STC-1000Pro. Detaillierte Informationen zu Funktionen, Bedienung, Installation und Spezifikationen für eine präzise Temperaturregelung bei Anwendungen wie Heimbrauen, Aquarien und Inkubation.
Vorview Elitech STC-1000Pro/STC-1000WiFi Smart-Temperaturregler – Benutzerhandbuch | Funktionen, Bedienung, Einrichtung
Benutzerhandbuch für die intelligenten digitalen Temperaturregler Elitech STC-1000Pro und STC-1000WiFi. Erfahren Sie mehr über Funktionen, Bedienung, Parametereinstellungen, Installation, Fehlerbehebung und App-Anbindung für eine präzise Temperaturregelung.
Vorview Elitech STC-1000Pro/STC-1000WiFi Smart-Temperaturregler – Benutzerhandbuch
Benutzerhandbuch für die intelligenten digitalen Temperaturregler Elitech STC-1000Pro und STC-1000WiFi. Beinhaltet Funktionen, Display, Bedienung, Parametereinstellungen, Installation, Fehlercodes und App-Integration für präzises Temperaturmanagement.