The ThermoPro TP260B is a professional-grade indoor/outdoor thermometer and hygrometer designed for accurate and reliable monitoring of temperature and humidity. Featuring a market-leading 1000ft/300m wireless range, it allows you to monitor conditions in multiple locations around your home or property. The main unit displays both indoor and outdoor readings, including trend arrows and 24-hour high/low records. Its easy-to-read backlit display and touch buttons ensure user-friendly operation. The remote sensor is weatherproof and cold-resistant, making it suitable for various outdoor environments.

Figure 1: ThermoPro TP260B Main Unit and Remote Sensor
Packungsinhalt
- 1 x Hauptthermometer
- 1 x Ferntemperatursensor
- 4 x AAA Size Batteries (included)
- 1 x Benutzerhandbuch
Key Components and Display

Abbildung 2: Ausführlich view of the main unit's display and touch buttons.
The main unit features a large, clear LCD display with distinct sections for indoor and outdoor readings. Key indicators include:
- AUS: Außentemperatur und Luftfeuchtigkeit.
- IN: Raumtemperatur und Luftfeuchtigkeit.
- CH1/2/3: Indicates the channel of the remote sensor being displayed.
- MAX MIN: Displays the highest and lowest recorded temperature/humidity over the last 24 hours.
- Trendpfeile: Shows whether temperature/humidity is rising, falling, or remaining stable.
- Anzeige für niedrigen Batteriestand: Meldet, wenn die Batterien ausgetauscht werden müssen.
- °F/°C-Taste: Schaltet zwischen Fahrenheit und Celsius um.
- CH/SYNC Button: Used for channel selection and sensor synchronization.
- Leicht berührungsempfindlicher Knopf: Aktiviert die Display-Hintergrundbeleuchtung für bessere Sichtbarkeit bei schwachem Licht.
- MAX/MIN/CLEAR-Taste: Toggles between Max/Min readings and clears recorded data.
Aufstellen
1. Einlegen der Batterie
- Haupteinheit: Öffnen Sie das Batteriefach auf der Rückseite des Hauptgeräts. Legen Sie 2 AAA-Batterien ein und achten Sie dabei auf die richtige Polarität (+/-). Schließen Sie das Fach.
- Fernbedienungssensor: Öffnen Sie das Batteriefach auf der Rückseite des Fernsensors. Legen Sie zwei AAA-Batterien ein und achten Sie dabei auf die richtige Polarität (+/-). Schließen Sie das Fach.
2. Synchronisierung
The main unit and remote sensor should automatically synchronize once batteries are installed. If synchronization fails or you are adding additional sensors, follow these steps:
- Place the main unit and remote sensor close to each other.
- Halten Sie die CH/SYNC button on the main unit for 3 seconds. The display will flash, indicating it is searching for the sensor.
- Drücken Sie die ZURÜCKSETZEN button on the back of the remote sensor.
- The main unit should display the remote sensor's readings within a few minutes.
Notiz: The ThermoPro TP260B supports up to 3 remote sensors (sold separately). To add more sensors, repeat the synchronization process for each additional sensor, selecting a different channel (CH1, CH2, or CH3) on the main unit using the CH/SYNC Taste.

Figure 3: The main unit can connect with up to three remote sensors.
3. Platzierungsoptionen
Die Haupteinheit bietet vielseitige Aufstellungsmöglichkeiten:
- Tischständer: Use the integrated fold-out stand for desktop or shelf placement.
- Wandhalterung: Nutzen Sie die Aufhängeöse auf der Rückseite, um es an der Wand zu befestigen.
- Eingebauter Magnet: Attach the unit to any metallic surface, such as a refrigerator.
For the remote sensor, choose a location that provides accurate readings and is within the 1000ft wireless range. Avoid direct sunlight or areas with extreme temperature fluctuations. The sensor is weatherproof, but placing it under an overhang or in a sheltered spot can prolong its lifespan.

Figure 4: Various placement options for the main unit.
Bedienungsanleitung
1. Umschalten der Temperatureinheiten (°F/°C)
Drücken Sie die °F/°C button on the front of the main unit to toggle between Fahrenheit and Celsius temperature displays.
2. Hintergrundbeleuchtung aktivieren
Berühren Sie die Licht button (light bulb icon) on the front of the main unit to activate the backlight for 15 seconds, improving readability in dark conditions.

Figure 5: The LCD screen features a backlight for easy reading.
3. ViewMAX/MIN-Datensätze erfassen und löschen
Drücken Sie die MAX/MIN/LÖSCHEN Taste einmal zu view the maximum temperature and humidity recorded since the last reset. Press it again to view the minimum records. To clear the 24-hour high/low records, press and hold the MAX/MIN/LÖSCHEN -Taste 3 Sekunden lang gedrückt.
4. Monitoring Multiple Channels
Wenn Sie mehrere Fernsensoren haben, drücken Sie die Taste CH/SYNC button repeatedly to cycle through the channels (CH1, CH2, CH3) and view the readings from each sensor. The main unit will automatically scroll through all active channels every few seconds.
Wartung
1. Batteriewechsel
Wenn die Anzeige für niedrigen Batteriestand erscheint, tauschen Sie die Batterien im jeweiligen Gerät (Hauptgerät oder Fernsensor) gegen neue AAA-Batterien aus. Achten Sie dabei auf die richtige Polarität.
Wichtiger Hinweis: If you only replace the remote sensor battery, please press and hold the CH/SYNC button of the receiver for 3 seconds to re-register, or by reinstalling the battery of the receiver within 3 minutes and then they will automatically resynchronize the data.
2. Reinigung und Lagerung
Reinigen Sie das Gerät und den Sensor mit einem weichen Tuch.amp cloth. Do not immerse in water or use abrasive cleaners. Store the device in a dry place away from extreme temperatures when not in use for extended periods.

Figure 6: The remote sensor is designed to withstand various weather conditions.
Fehlerbehebung
- No readings on display or "---" shown:
- Prüfen Sie, ob die Batterien korrekt und mit der richtigen Polarität eingelegt sind.
- Ersetzen Sie alte Batterien durch neue.
- Ensure the main unit and sensor are within the 1000ft wireless range and free from major obstructions.
- Perform a manual synchronization as described in the "Setup" section.
- Ungenaue Messwerte:
- Ensure the sensor is not placed in direct sunlight, near heat sources, or in areas with poor air circulation.
- Allow the units to stabilize for at least 30 minutes after setup for accurate readings.
- The 1000-ft range may be affected by obstructions in your home layout (including walls, router, trees, and bushes as well as building materials such as metal and glass). Try relocating the sensor or main unit.
- Das Display ist dunkel oder flackert:
- Tauschen Sie die Batterien im Hauptgerät aus.
Technische Daten
| Besonderheit | Detail |
|---|---|
| Marke | ThermoPro |
| Modellname | TP260B |
| Konnektivitätstechnologie | 915 MHz Funk |
| Drahtlose Reichweite | Up to 1000ft / 300m (without obstructions) |
| Temperaturgenauigkeit | +/-0.5°F |
| Feuchtigkeitsgenauigkeit | +/-2-3% RH |
| Stromversorgung (Haupteinheit) | 2 x AAA-Batterien |
| Stromversorgung (Fernsensor) | 2 x AAA-Batterien |
| Outdoor Sensor Resistance | Weatherproof, Cold-resistant (-4°F/-20°C) |
| Anzeigetyp | Active Matrix LCD with Backlight |
| Platzierungsoptionen | Tabletop, Wall Mount, Magnet |
Garantie und Support
ThermoPro products come with a warranty. For detailed warranty information, product registration, or technical support, please visit the official ThermoPro webBesuchen Sie die Website oder konsultieren Sie die Kontaktinformationen auf Ihrer Produktverpackung.
Sie können das vollständige Benutzerhandbuch auch hier im PDF-Format herunterladen: ThermoPro TP260B User Manual (PDF)