Elitech LMG-10

Elitech LMG-10 Digital Manifold Gauge Set User Manual

Modell: LMG-10

1. Einleitung

The Elitech LMG-10 is a professional digital manifold gauge set designed for HVAC/R system maintenance, installation, and troubleshooting. It provides precise measurements for pressure, temperature, and vacuum, supporting a wide range of refrigerants. This manual provides detailed instructions for the proper setup, operation, and maintenance of your LMG-10 unit.

Elitech LMG-10 Digital Manifold Gauge Set with hoses and temperature clamps

Figure 1.1: Elitech LMG-10 Digital Manifold Gauge Set. The set includes the main digital manifold unit, three color-coded refrigerant charging hoses (red, yellow, blue), and two temperature clamps.

2. Hauptmerkmale

The Elitech LMG-10 offers a comprehensive set of features for efficient HVAC/R system analysis:

  • Temperaturkompensation: Monitors pressure holding and vacuum leakage tests with precise temperature compensation.
  • Multi-Refrigerant Support: Supports 88 types of refrigerants for broad application.
  • Automatische Berechnungen: Auto-calculation of superheating and subcooling values.
  • Mehrere Einheiten: Supports 5 pressure units (psi, kg/cm², kPa, MPa, bar) and 2 temperature units (°F/°C).
  • Benutzerfreundliches Design: Features a large, easy-to-read display and an auto-off function for power saving.
  • Durable Hoses: Includes 3 x 59" (1.5m) A/C charging hose set with heavy-duty brass connections, rated for 500 PSI working pressure and 4000 PSI burst pressure.
Elitech LMG-10 Digital Manifold Gauge features including temperature compensation, 88 refrigerants, superheating/subcooling, large display, compact size, and 200h battery life.

Abbildung 2.1: Überview of Elitech LMG-10 features, highlighting temperature compensation, 88 refrigerant types, superheating & subcooling calculation, large display, compact design, and extended battery life.

3. Packungsinhalt

Überprüfen Sie, ob alle Artikel in Ihrem Paket vorhanden sind:

  • 1 x Elitech LMG-10 Digital Manifold Gauge
  • 3 x Refrigerant Charging Hoses (Red, Yellow, Blue)
  • 2 x Temperatur Clamps
  • 1 x Benutzerhandbuch

4. Produktkomponenten und Spezifikationen

4.1. Main Unit Components

Labeled diagram of Elitech LMG-10 Digital Manifold Gauge showing LCD screen, temperature probe port, hook, battery compartment, warning label, control buttons, sight glass, control valves, refrigerant hose brackets, and fittings.

Figure 4.1: Labeled diagram of the Elitech LMG-10 Digital Manifold Gauge. Key components include the LCD screen, temperature probe port, integrated hook, battery compartment, warning label, control buttons, sight glass, control valves, refrigerant hose brackets, and refrigerant hose fittings.

4.2. Refrigerant Hoses

The included refrigerant hoses are designed for durability and safety:

  • Länge: 59 Zoll (1.5 Meter)
  • Schraubengewinde: 1/4" SAE – 1/4" SAE
  • Arbeitsdruck: 500 PSI (Hoses are rated for 800 PSI max working pressure)
  • Berstdruck: 4000 PSI
  • Farbkodierung: Red for high pressure, Blue for low pressure, Yellow for refrigerant charging.
Elitech LMG-10 refrigerant charging hoses, 59 inches (150 cm) long with 1/4 inch SAE screw threads.

Figure 4.2: Refrigerant charging hoses, showing their length and thread type.

Close-up of Elitech LMG-10 refrigerant hoses showing working pressure of 800 PSI and burst pressure of 4000 PSI.

Abbildung 4.3: Nahaufnahme view of the hose connections, indicating their working and burst pressure ratings.

Color coding for Elitech LMG-10 refrigerant hoses: Red for high pressure, Blue for low pressure, Yellow for refrigerant.

Figure 4.4: Color-coded hoses for easy identification of their function: Red for high pressure, Blue for low pressure, and Yellow for refrigerant.

4.3. Technische Daten

Dimensions of Elitech LMG-10 Digital Manifold Gauge: 18 cm height, 10 cm width, 4.5 cm depth, weight 0.95 kg. Also lists measuring range, units, accuracy, battery life, and working temperature range.

Figure 4.5: Physical dimensions and key technical specifications of the LMG-10 unit.

SpezifikationWert
ModellLMG-10
Messbereich-14.5 bis 800 psi
Genauigkeit±0.5 % vom Endwert
Druckeinheitenpsi, kg/cm², kPa, MPa, bar
Temperatureinheiten° F / ° C
Arbeitstemperaturbereich14°F ~ 122°F (-10°C ~ 50°C)
AkkulaufzeitCa. 200 Stunden
Stromversorgung3 x AA-Batterien
Abmessungen (ca.)18 cm (H) x 10 cm (W) x 4.5 cm (D)
Gewicht ca.)0.95 kg
MaterialBrass (fittings)

5. Einrichtung und Erstgebrauch

5.1. Einlegen der Batterie

  1. Locate the battery compartment on the back of the LMG-10 unit.
  2. Öffnen Sie die Batterieabdeckung.
  3. Legen Sie drei (3) AA-Batterien ein und achten Sie dabei auf die richtige Polarität (+/-).
  4. Schließen Sie die Batterieabdeckung fest.
Diagram showing how to install 3 AA batteries into the Elitech LMG-10 Digital Manifold Gauge.

Figure 5.1: Illustration of battery installation and various display modes.

5.2. Anschlusstemperatur Clamps

  1. Schließen Sie die Temperaturklamps to the designated temperature probe ports on the LMG-10 unit.
  2. Befestigen Sie dieamps securely to the refrigerant lines to measure pipe temperature.

5.3. Verbindungsschläuche

  1. Identify the high-pressure (red), low-pressure (blue), and refrigerant (yellow) hoses.
  2. Connect the appropriate ends of the hoses to the corresponding ports on the LMG-10 manifold.
  3. Connect the other ends of the hoses to the HVAC/R system service ports or refrigerant tank as required for your task.
  4. Stellen Sie sicher, dass alle Verbindungen dicht sind, um Lecks zu vermeiden.

6. Bedienungsanleitung

6.1. Ein-/Ausschalten

  • Drücken Sie die Leistung Taste (Symbol: Kreis mit senkrechtem Strich) to turn the unit ON.
  • Halten Sie die Leistung Taste zum Ausschalten des Geräts.

6.2. Unit Selection (Pressure and Temperature)

  • Drücken Sie die MODUS button to cycle through pressure units (psi, kg/cm², kPa, MPa, bar).
  • Drücken Sie die °F/°C Taste zum Umschalten zwischen Fahrenheit und Celsius als Temperatureinheit.

6.3. Refrigerant Selection

The LMG-10 supports 88 types of refrigerants. To select the desired refrigerant:

  1. Drücken Sie die MODUS button until the refrigerant selection mode is active.
  2. Verwenden Sie die Pfeiltasten (left/right arrows) to scroll through the list of available refrigerants.
  3. Bestätigen Sie Ihre Auswahl.
Elitech LMG-10 supports 88 types of refrigerants, with a partial list including R134a, R410a, R22, R407C, etc.

Figure 6.1: The LMG-10's display showing the extensive list of 88 supported refrigerants.

6.4. Druck- und Temperaturmessung

Once connected and powered on, the LMG-10 will display real-time pressure and temperature readings. The display shows high-side and low-side pressures, as well as saturation temperatures for the selected refrigerant.

6.5. Vacuum Measurement

The LMG-10 can monitor vacuum levels during evacuation processes. Refer to the display for vacuum readings and progress.

6.6. Berechnung von Überhitzung und Unterkühlung

The device automatically calculates superheating (SH) and subcooling (SC) values based on the measured pressures and temperatures, providing critical data for system analysis.

Screenshots of Elitech LMG-10 display showing pressure and temperature measurement, vacuum measurement, temperature compensation, and superheating/subcooling calculation.

Figure 6.2: Various display screens of the LMG-10, illustrating pressure and temperature measurement, vacuum measurement, temperature compensation, and automatic calculation of superheating/subcooling.

6.7. Auto-Off Settings

To conserve battery life, the LMG-10 features an adjustable auto-off function. You can set the auto-off time to 5, 10, 15, 30, or 60 minutes.

7. Wartung und Pflege

7.1. Reinigung

  • Wischen Sie das Gerät mit einem weichen, damp Tuch. Keine Scheuer- oder Lösungsmittel verwenden.
  • Ensure the ports and connections are free from debris.

7.2. Batteriewechsel

Replace batteries when the low battery indicator appears on the display. Follow the instructions in Section 5.1.

7.3. Speicherung

  • When not in use for an extended period, remove the batteries to prevent leakage and damage to the unit.
  • Store the LMG-10 in a cool, dry place, away from direct sunlight and extreme temperatures.

8. Fehlerbehebung

If you encounter issues with your Elitech LMG-10, refer to the table below for common problems and solutions:

ProblemMögliche UrsacheLösung
Gerät lässt sich nicht einschaltenLeere oder falsch eingelegte BatterienErsetzen Sie die Batterien durch neue und achten Sie dabei auf die richtige Polarität.
Ungenaue DruckwerteLoose hose connections; Sensor calibration needed; Incorrect refrigerant selectedCheck and tighten all hose connections. If issue persists, contact customer support for calibration guidance. Verify the correct refrigerant is selected.
Temperatur Klamps not readingClamps not properly connected; Damaged clamp KabelStellen Sie sicher, dass clamps are fully plugged into the ports. Inspect cable for damage.
Das Display ist dunkel oder flackertNiedriger AkkustandBatterien ersetzen.

Sollte das Problem nach Anwendung dieser Lösungsansätze weiterhin bestehen, wenden Sie sich bitte an den Elitech-Kundendienst.

9. Garantie und Kundendienst

Elitech Technology Inc. provides a 12 Monate Garantie for the LMG-10 Digital Manifold Gauge Set from the date of purchase. This warranty covers defects in materials and workmanship under normal use.

For technical assistance, warranty claims, or any other inquiries, please contact Elitech customer support. Elitech offers 24/7 Kundensupport service via email and phone.

Elitech customer support icon representing 24/7 service.

Figure 9.1: Elitech customer support is available 24/7.

You can find more information and contact details on the official Elitech webWebsite oder über deren Amazon-Shop: Elitech Amazon Store.

Zugehörige Dokumente - LMG-10

Vorview Elitech WJL-6000S Koronadetektor Benutzerhandbuch
Benutzerhandbuch für den Elitech WJL-6000S Corona-Detektor mit detaillierten Anweisungen zu Betrieb, Erkennung, Fehlerbehebung und Wartung zur Erkennung von Kältemittellecks in verschiedenen Systemen.
Vorview Elitech MS-100 PLUS Smart Digital Manometer – Benutzerhandbuch
Ausführliches Benutzerhandbuch für das Elitech MS-100 PLUS Smart Digital Manometer, einschließlich Produkteinführung, Sicherheitshinweise und mehr.view, Tastenfunktionen, technische Parameter und Kurzanleitungen für Kälte- und Klimatechniksysteme.
Vorview Elitech DMG-2SE Digital Manifold Gauge User Manual
User manual for the Elitech DMG-2SE Digital Manifold Gauge. Features include a built-in database of 88 refrigerants that automatically calculates saturation temperature. This guide details operation, technical specifications, safety, and maintenance for HVAC applications, ensuring efficient and accurate measurements.
Vorview Elitech MS-100 Digitales Manometer: Funktionen, Bedienung und Spezifikationen
Ausführlicher Leitfaden zum digitalen Manometer Elitech MS-100 mit Informationen zu Funktionen, schneller Bedienung, technischen Spezifikationen, Vorsichtsmaßnahmen und Produktdetails für HLK- und Kälteanlagen.
Vorview Elitech MS-Serie Digitales Manometer – Benutzerhandbuch
Benutzerhandbuch für das digitale Manometer der Elitech MS-Serie, einschließlich Produktbeschreibung, allgemeiner ÜbersichtviewTastenfunktionen, Spezifikationen, Kurzanleitung, Bedienungsschritte, intelligente Anwendungen und Wartung.
Vorview Elitech MS-800 Serie Digitales Manometer – Benutzerhandbuch & Spezifikationen
Ausführliches Benutzerhandbuch für das digitale Manometer der Elitech MS-800 Serie, mit Produkteinführung, Sicherheitsrichtlinien, Umweltschutz, detaillierten Spezifikationen und Kurzanleitungen für Druck- und Temperaturmessungen, Haltedruckprüfungen und Kältemittelbefüllung für HLK- und Kälteanlagen.