Prity K1 R

Prity K1 R Holzofen Benutzerhandbuch

Model: K1 R

1. Einleitung

Welcome to the user manual for your new Prity K1 R Wood Stove. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your wood stove. Please read this manual thoroughly before using the appliance to ensure proper function and to prevent potential hazards.

1.1 Sicherheitshinweise

  • Brandgefahr: Always maintain proper clearances from combustible materials. Never leave the stove unattended while in operation.
  • Kohlenmonoxid: Ensure adequate ventilation and proper chimney installation to prevent carbon monoxide buildup. Install carbon monoxide detectors.
  • Heiße Oberflächen: The stove surfaces become extremely hot during operation. Use protective gloves and keep children and pets away.
  • Kraftstoff: Only burn dry, seasoned wood. Never use flammable liquids to start or rekindle a fire.
  • Schornsteinwartung: Regular inspection and cleaning of the chimney are crucial to prevent creosote buildup and chimney fires.

2. Produktüberschreitungview

The Prity K1 R is a robust wood stove designed for efficient heating. It features a durable steel plate construction, a spacious firebox, and an ash pan for easy cleaning. The stove is equipped with legs for stability and a flue collar for chimney connection.

Front view of the Prity K1 R wood stove with a fire burning inside the firebox.

Abbildung 2.1: Front view of the Prity K1 R wood stove with a fire burning inside the firebox, showcasing the glass door and the ash pan below.

Front view of the Prity K1 R wood stove without fire.

Abbildung 2.2: Front view of the Prity K1 R wood stove, showing the interior of the firebox with refractory lining and the closed ash pan.

Hinteren view of the Prity K1 R wood stove.

Abbildung 2.3: Hinteren view of the Prity K1 R wood stove, illustrating the flue pipe connection at the top and the overall steel construction.

3. Einrichtung

3.1 Standort und Abstände

The Prity K1 R wood stove must be installed on a non-combustible floor protector (hearth) that extends beyond the stove's footprint according to local building codes. Maintain the following minimum clearances from combustible materials:

  • Hinteren: 400 mm
  • Sides (Left & Right): 400 mm
  • Front: 800 mm
  • Decke: 600 mm

These clearances are critical for fire safety. Consult local regulations and a certified installer if unsure.

3.2 Kaminanschluss

Connect the stove to a suitable chimney system using a flue pipe with a diameter of 130 mm. Ensure all connections are sealed properly to prevent smoke leakage and ensure optimal draft. The chimney must be clean and in good condition.

3.3 First Firing (Curing Process)

During the first few fires, the paint on the stove will cure. This process may produce some smoke and odor. Ensure the area is well-ventilated during this time. Start with small fires and gradually increase the heat over several days to allow the stove to cure properly and prevent damage to the finish.

4. Bedienungsanleitung

4.1 Kraftstoffart

Only use dry, seasoned hardwood as fuel. Wood should be split and allowed to dry for at least 6-12 months. Burning wet or unseasoned wood reduces efficiency, increases creosote buildup, and can lead to excessive smoke. Never burn:

  • Treated wood, painted wood, or particle board
  • Plastics, garbage, or chemical waste
  • Brennbare Flüssigkeiten

4.2 Das Feuer entzünden

  1. Open the primary air intake (usually located on the ash pan door) fully.
  2. Place crumpled newspaper or firelighters at the bottom of the firebox.
  3. Stapeln Sie kleine Anzündholzstücke auf das Zeitungspapier/die Anzündwürfel.
  4. Zünde die Zeitung/Anzünder an.
  5. Sobald das Anzündholz gut brennt, geben Sie nach und nach größere Stücke abgelagerten Holzes hinzu.
  6. Close the firebox door once the fire is established.

4.3 Luftkontrolle

The Prity K1 R stove features air controls to regulate the burn rate and heat output:

  • Primärluft: Controls the air entering the firebox from below the grate, feeding the initial combustion. Open fully for starting a fire and adding new fuel. Reduce once the fire is established.
  • Secondary Air (if applicable): Provides air to burn off gases above the fire, improving efficiency and reducing emissions. This may be controlled by a separate vent or integrated into the design.
  • Rauch Damper/Throttle: A control on the chimney pipe (if installed) can be used to adjust the draft and slow down the burn rate. Use carefully to avoid excessive smoke or reduced performance.

4.4 Tanken

When the flames have died down and only glowing embers remain, it is time to refuel. Open the primary air control, slowly open the firebox door to allow any smoke to clear, and then add new pieces of wood. Close the door and adjust air controls as needed.

4.5 Over-firing

Avoid over-firing the stove, which occurs when too much fuel is burned at too high a rate. This can lead to excessive temperatures, potentially damaging the stove and chimney, and increasing the risk of a chimney fire. If the stove glows red, it is over-firing. Reduce air intake immediately.

5. Wartung

5.1 Ascheentfernung

Regularly remove ash from the ash pan. Do not allow ash to build up to the level of the grate, as this can restrict airflow and damage the grate. Always use a metal container with a tight-fitting lid for ash disposal, and store it away from combustible materials.

5.2 Glasreinigung

The glass in the firebox door can be cleaned when the stove is cold. Use a damp cloth dipped in fine wood ash or a specialized stove glass cleaner. Avoid abrasive cleaners that can scratch the glass.

5.3 Schornsteinreinigung

The chimney and flue pipe should be inspected and cleaned at least once a year, or more frequently depending on usage and fuel type. Creosote buildup is a fire hazard. It is highly recommended to hire a certified chimney sweep for this task.

5.4 Allgemeine Inspektion

Periodically inspect the stove for any signs of wear or damage, including:

  • Door seals and gaskets: Ensure they are intact and providing a good seal.
  • Firebox lining (refractory bricks): Check for cracks or deterioration.
  • Flue pipe connections: Ensure they are secure and free of leaks.
  • Air controls: Verify they operate smoothly.

6. Fehlerbehebung

ProblemMögliche UrsacheLösung
Rauch dringt in den RaumPoor draft, blocked chimney, wet wood, door opened too quicklyCheck chimney for blockages, ensure adequate air supply, use dry wood, open door slowly
Geringe WärmeabgabeWet wood, insufficient air, small fire, chimney too coldUse dry wood, open air controls, build a larger fire, pre-heat chimney
Fire goes out quicklyLack of fuel, insufficient air, excessive draftAdd more fuel, open air controls, adjust flue damper (if present)
Glas wird schwarzWet wood, insufficient secondary air, low burning temperatureUse dry wood, ensure proper air circulation, burn at higher temperatures
Internal stones crackNormal wear and tear, rapid temperature changes, impactMinor cracks are often cosmetic and do not affect performance. Replace severely damaged or crumbling stones.

7. Spezifikationen

Below are the key technical specifications for the Prity K1 R Wood Stove:

BesonderheitDetail
MarkePrity
ModellK1 R
Gesamtabmessungen (L x B x H)450 x 380 x 750 mm
Firebox Dimensions (L x W x H)370 x 295 x 350 mm
Gewicht66 kg
Nominal Heating Power9 kW
Rauchrohrdurchmesser130 mm
MaterialSteel plate (2mm body, 3-4mm top)
KraftstoffartHolz
EnergieeffizienzklasseA
Effizienz77.8 %
HerstellerPrity 95 LTD
Energy label for the Prity K1 R wood stove.

Abbildung 7.1: Energy label for the Prity K1 R wood stove, indicating an energy efficiency class of A and a nominal heat output of 9.0 kW.

Declaration of Performance for the Prity K1 R wood stove.

Abbildung 7.2: Declaration of Performance for the Prity K1 R wood stove, detailing essential characteristics, fire safety, emissions, and nominal heat output.

8. Garantie und Support

For warranty information and customer support, please refer to the documentation provided at the time of purchase or contact your retailer. Keep your proof of purchase for any warranty claims. For technical assistance or spare parts, please contact the manufacturer, Prity 95 LTD, or an authorized service center.

Zugehörige Dokumente - K1 R

Vorview Prity-Kessel: Technische Beschreibung, Installations- und Betriebshandbuch
Umfassender Leitfaden für Prity-Heizkessel für Wohngebäude mit technischen Daten, Installationsverfahren, Betriebsanweisungen, Wartung und Fehlerbehebung für Festbrennstoff- und Pelletmodelle.
Vorview Ravelli Thor HE+ Holzofen: Installations-, Gebrauchs- und Wartungsanleitung
Ausführlicher Leitfaden für den Ravelli Thor HE+ Holzofen: Installation, Betrieb, Sicherheit, Wartung, technische Daten und Fehlerbehebung. Für eine sichere und effiziente Nutzung Ihres Holzofens.
Vorview Pelletofen Ravelli R 1000 Pro: Bedienungs- und Wartungshandbuch
Umfassende Anleitung für den Pelletofen Ravelli R 1000 Pro von Aico SpA mit Informationen zu Installation, Betrieb, Sicherheit, Wartung und Fehlerbehebung für eine effiziente Beheizung Ihres Zuhauses.
Vorview ECOPALEX GTM Installations- und Wartungshandbuch
Ausführlicher Leitfaden für den Holzofen Palazzetti ECOPALEX GTM, der Installation, Sicherheit, Betrieb, Wartung und Entsorgung abdeckt. Gewährleistet optimale Leistung und sichere Nutzung.
Vorview Ravelli Dual 7 & Dual 9 – Bedienungs- und Wartungshandbuch – Anleitung für sicheren Betrieb und Installation
Dieses umfassende Handbuch enthält alle wichtigen Informationen für die sichere Installation, den Betrieb, die Wartung und die Fehlerbehebung der Pelletöfen Ravelli Dual 7 und Dual 9. Erfahren Sie mehr über technische Spezifikationen, Sicherheitsmaßnahmen und die optimale Nutzung.
Vorview Ravelli Flexi 7 & Flexi 9 Pelletöfen: Gebrauchs- und Wartungsanleitung
Ausführlicher Leitfaden für die Pelletöfen Ravelli Flexi 7 und Flexi 9: Installation, Betrieb, Wartung und Fehlerbehebung. Gewährleisten Sie die sichere und effiziente Nutzung Ihres Ravelli-Ofens.