The Enttec DIN Pixie 73539 is a compact, DIN-rail mountable DMX to LED pixel protocol converter. It is designed to provide flexible control for architectural, commercial, and entertainment lighting installations by converting DMX512 signals into various LED pixel protocols.

This manual provides essential information for the safe and efficient operation of your DIN Pixie. Please read it thoroughly before installation and use.

2. Sicherheitshinweise

WARNING: This unit is intended for indoor use only. Do not expose to rain or moisture. Doing so will void the warranty.

  • Never plug this unit into a dimmer.
  • Always be sure to mount this unit in an area that will allow sufficient ventilation.
  • Label any RJ45/6 DMX connector and DO NOT connect to non-DMX port (e.g., Ethernet Switch). Connecting unlike systems could result in serious damage to Storm8 and equipment.
  • All ports feature ESD surge protection and resettable fuses to block external faults and electrical noise propagation.

3. Inhalt der Box

Prüfen Sie, ob alle Artikel in der Box vorhanden sind:

  • Enttec DIN Pixie unit
  • DIN-Montagehalterung
  • USB Type-A to USB 2.0 Type B Cable

4. Körperliche Übergriffeview und Anschlüsse

Front view of Enttec DIN Pixie with status LED and branding

Abbildung 4.1: Vorderseite view of the Enttec DIN Pixie controller, showing the status LED and branding.

Spitze view of Enttec DIN Pixie showing DMX input ports

Abbildung 4.2: Oben view of the Enttec DIN Pixie, highlighting the two DMX input ports (DMX 1 and DMX 2) and the enttec.com URL.

Unten view of Enttec DIN Pixie showing USB and SPI outputs

Abbildung 4.3: Unten view of the Enttec DIN Pixie, showing the USB 2.0 Type-B input and two 3-pin Phoenix SPI output terminals (labeled 1 and 2) with VCC limit 5-48VDC.

4.1. DMX Input (RJ45)

The DIN Pixie features two RJ45 ports for DMX input. These ports are compliant with ANSI E1.27-2.

RJ45 Pin for DMX Input
StiftFunktion
Stift 1Daten +
Stift 2Data -
Stift 7/8Boden

4.2. SPI Output (3 Pin Phoenix)

The unit provides two 3-pin Phoenix connectors for SPI output. These outputs deliver power and data to your LED pixels. Ensure the VCC limit of 5-48VDC is respected.

  • 0V: Ground connection for the pixel strip.
  • DATA: Data signal for the pixel strip.
  • VCC: Bandtage supply for the pixel strip (5-48VDC).

4.3. USB 2.0 Type-B Input

A robust USB Type-B connector is provided for configuration and firmware updates. It is also backward compatible with the Enttec Pixie Driver API for USB-SPI control.

5. Einrichtung und Installation

5.1. Montage

The DIN Pixie is designed for DIN-rail mounting. Use the included DIN Mounting Bracket to secure the unit to a standard DIN rail.

Unten view of Enttec DIN Pixie with DIN rail clip attached

Abbildung 5.1: Unten view of the Enttec DIN Pixie showing the attached DIN rail mounting clip.

5.2. Stromversorgung des Geräts

The DIN Pixie operates on a wide voltage range of 5-48VDC. It can be powered from the same source as your LED pixels via the VCC and 0V terminals on the SPI output connectors. Alternatively, power can be supplied via the USB connection.

5.3. Connecting LED Pixels

Connect your LED pixel strips or dots to the SPI output terminals. Ensure correct polarity (0V, DATA, VCC) and that the voltage supplied matches the requirements of your pixel strips and is within the 5-48VDC limit of the DIN Pixie.

The DIN Pixie supports RGB and RGBW pixel strips and dots.

5.4. DMX Input Connection

Connect your DMX source to the RJ45 DMX input ports. The unit can receive DMX512-A data.

5.5. Konfiguration

The DIN Pixie is configurable and updatable via USB using Enttec's free PRO-MANAGER software. This software allows you to:

  • Configure DMX starting address.
  • Set pixel grouping functions to optimize channel usage.
  • Select between control modes.
  • Test output sequences (no external data source required).
  • Firmware aktualisieren.

For the latest version of PRO-MANAGER software and drivers, visit the official Enttec webWebsite: enttec.com

6. Betriebsarten

The DIN Pixie supports various operating modes, indicated by the status LED:

  • AUF: Overheating/Error
  • 0.5Hz: Leerlauf
  • 2Hz: Standalone playback
  • 8Hz: DMX-Empfang
  • 25Hz: Receiving from USB

6.1. DMX-Steuerungsmodus

When receiving DMX data, the DIN Pixie converts up to 2 DMX universes (1024 channels) into SPI pixel protocols. The DMX starting address and pixel grouping can be configured via PRO-MANAGER.

The unit can be configured to play a show on DMX loss or blackout output, providing a fail-safe mechanism.

6.2. Standalone Playback Mode

The DIN Pixie has inbuilt flash memory for standalone show playback (4000 frames, approximately 100 seconds). Shows can be recorded and uploaded using PRO-MANAGER. Standalone playback can include sequence advance control options such as play count, loop delay, and play on power up.

6.3. USB Control Mode

The DIN Pixie can be controlled directly via the USB Type-B connector using the Enttec Pixie Driver API. This allows for direct control from a computer or compatible device.

7. Wartung

The Enttec DIN Pixie is designed for reliable operation and requires minimal maintenance.

  • Reinigung: Reinigen Sie die Außenseite des Geräts mit einem weichen, trockenen Tuch. Verwenden Sie keine flüssigen Reiniger oder Lösungsmittel.
  • Firmware-Updates: Periodically check the Enttec website for firmware updates. Keeping the firmware current ensures optimal performance and access to new features. Firmware updates are performed using the PRO-MANAGER software.
  • Belüftung: Ensure the unit is mounted in an area with adequate ventilation to prevent overheating.

8. Fehlerbehebung

If you encounter issues with your DIN Pixie, refer to the following common troubleshooting steps:

  • Kein Strom/LED-Anzeigen aus:
    • Check power connections to the VCC/0V terminals or USB port.
    • Stellen Sie sicher, dass die Stromversorgungslautstärketage is within the 5-48VDC range.
    • Vergewissern Sie sich, dass die Stromquelle aktiv ist.
  • No Pixel Output:
    • Confirm correct wiring of 0V, DATA, and VCC to the pixel strips.
    • Check if the DMX source is active and sending data (status LED should be 8Hz).
    • Verify pixel protocol and DMX starting address settings in PRO-MANAGER.
    • Ensure the pixel strips themselves are functional.
  • DMX Input Not Detected (LED 8Hz not flashing):
    • Überprüfen Sie die DMX-Kabelverbindungen.
    • Ensure the DMX source is transmitting.
    • Confirm the DMX source is using USITT DMX512-A protocol.
  • PRO-MANAGER Connection Issues:
    • Stellen Sie sicher, dass das USB-Kabel fest angeschlossen ist.
    • Install the correct FTDI drivers for your operating system. Refer to the Enttec website for driver information.
    • Restart PRO-MANAGER and reconnect the USB cable.
  • Overheating/Error (LED ON):
    • Check for adequate ventilation around the unit.
    • Ensure the ambient temperature is within the operating range (0°C to 50°C).
    • Reduce the load on the SPI outputs if possible.

For further assistance, please contact Enttec support or visit their website for detailed guides and FAQs.

9. Spezifikationen

BesonderheitSpezifikation
Anschlüsse1x USB 2.0 Type-B Input, 2x DMX Input (RJ45), 2x SPI Output (3 Pin Phoenix)
ESD-SchutzResettable fuse per port
IP-SchutzartIP20
LED-AnzeigeYes (Power and output status)
EingabeprotokollUSITT DMX512-A
Data Output TypeSPI (Supported protocols listed on Enttec webWebsite)
Maximum Output Channels2 Universes (1024ch), duplicated on both ports
Max. Output Refresh Rate40FPS
Latenz5 Millisekunden
Eingangslautstärketage5 - 48V DC (via USB/Ether output port VCC terminal)
Maximale Leistungsaufnahme1.5 W
Max. Rated Current per screw terminal (VCC / 0V)10 A
KonfigurationssoftwarePRO-MANAGER
Firmware-AktualisierungenPRO-MANAGER
Show Recording/UploadPRO-MANAGER
Umgebungstemperatur bei Betrieb0 °C bis 50 °C (32 °F bis 122 °F)
Umgebungsfeuchtigkeit im Betrieb5-95% (nicht kondensierend)
GehäusematerialABS-Kunststoff
MontagemöglichkeitLÄRM
Stückgewicht95 g
Abmessungen (H x B x L)1.22 x 3.07 x 3.66 Zoll (30.9 x 77.9 x 92.98 mm)
Versandgewicht0.22kg / 0.49lbs

Note: For the most current and detailed specifications, please refer to the official Enttec datasheet on their webWebsite.

10. Garantie und Support

10.1. Gewährleistung

The Enttec DIN Pixie comes with a 2-year return to base manufacturer warranty, supported by 3rd party software. For detailed warranty terms and conditions, please visit the official Enttec webWebsite.

10.2. Technischer Support

For technical assistance, troubleshooting, or further information, please visit the Enttec webWebsite besuchen oder deren Support-Team kontaktieren:

  • WebWebsite: www.enttec.com
  • Weitere Informationen finden Sie im webWebsite für Kontaktdaten und Support-Ressourcen.