1. Einleitung
The MiLESEEY MG-10 is a portable 4-in-1 gas detector designed to continuously monitor the concentration of four critical gases: Hydrogen Sulfide (H2S), Oxygen (O2), Carbon Monoxide (CO), and combustible gases (EX). This device is equipped with high-quality sensors to provide accurate and reliable readings, ensuring safety in various environments. This manual provides essential information for the proper use, maintenance, and understanding of your MG-10 gas detector.

Figure 1: The MiLESEEY MG-10 Gas Detector is an ideal safety solution for various professional and home environments, including kitchens, industrial settings, and emergency situations.
2. Sicherheitshinweise
Please read and understand all safety instructions before operating the MG-10 gas detector. Failure to follow these instructions may result in injury, damage to the device, or inaccurate readings.
- Professioneller Einsatz: This device is intended for professional use in environments where gas monitoring is required.
- Kalibrierung: While factory calibrated, professional recalibration and zero adjustment are supported and recommended periodically to maintain accuracy.
- Batteriesicherheit: Use only the provided charging accessories. Do not attempt to open or replace the internal lithium-ion battery.
- Umgebungsbedingungen: Operate the device within specified temperature (up to 50°C) and humidity (up to 95%) ranges.
- Alarmreaktion: Always respond immediately to any alarm indications (audible, visual, or vibration) and follow established safety protocols.
- Schäden vermeiden: Protect the device from severe impacts, extreme temperatures, and exposure to water or corrosive substances.
3. Produktüberschreitungview
3.1 Komponenten

Figure 2: Key components and dimensions of the MG-10 Gas Detector.
The MG-10 gas detector features a robust design with clearly labeled components:
- Alarmlicht: Visual indicator for gas detection alarms.
- Gürtelschnalle: For easy attachment to clothing or a belt, enhancing portability.
- LCD Bildschirm: Displays real-time gas concentrations, battery status, and menu options.
- Lautsprecher: Emits audible alarms and voice broadcasts.
- Drücken Sie die Tasten: Used for navigation and selection within the device's menu.
- Gassensor: Located at the bottom, responsible for detecting gas concentrations.
3.2 Anzeigeschnittstelle
The large backlit LCD screen provides clear readings for each monitored gas:
- H2S: Hydrogen Sulfide concentration in parts per million (PPM).
- O2: Sauerstoffkonzentration in Prozenttage (%).
- CO: Kohlenmonoxidkonzentration in Teilen pro Million (PPM).
- EX: Combustible gas concentration as a percentage of Lower Explosive Limit (%LEL).
4. Einrichtung
4.1 Aufladen des Geräts
The MG-10 is powered by an 1800mAh rechargeable lithium-ion battery. Before first use, ensure the device is fully charged.
- Connect the provided charging cable to the device's charging port.
- Verbinden Sie das andere Ende des Kabels mit einem kompatiblen USB-Netzteil (nicht im Lieferumfang enthalten) oder einem USB-Anschluss Ihres Computers.
- Der Ladestatus wird auf dem Bildschirm angezeigt.
- A full charge typically provides over 8 hours of continuous operation.
4.2 Erstes Einschalten
The MG-10 gas detector comes factory calibrated and is ready for immediate use upon power-on.
- Halten Sie den Netzschalter gedrückt, bis sich das Gerät einschaltet.
- The device will perform a self-test and display current gas readings.
- Allow a brief warm-up period for sensor stabilization before relying on readings.
5. Bedienungsanleitung
5.1 Gaserkennung
The MG-10 continuously monitors the ambient air for the presence and concentration of H2S, O2, CO, and EX gases. Real-time readings are displayed on the LCD screen.

Figure 3: The MG-10 is built with high sensitivity and stability sensors for quick response.
5.2 Alarmsystem
The MG-10 features a comprehensive multi-alarm system to alert users to dangerous gas levels. Alarms are triggered when gas concentrations exceed preset levels.

Figure 4: The MG-10 features powerful alarm modes including warning light, voice broadcast, vibration, and alarm display.
- Visueller Alarm: Flashing LEDs indicate an alarm condition.
- Hörbarer Alarm: A loud sound from the speaker alerts users. The device also supports voice broadcasts.
- Vibrationsalarm: An internal vibrating alarm provides a tactile alert, useful in noisy environments.
- Alarm Data Storage: The device stores alarm records with digital time stamps, allowing users to review historical alarm events through the menu.
5.3 Menüfunktionen
The MG-10 features a user-friendly interface for accessing various settings and information.

Figure 5: The MG-10's menu functions provide a humanized operation interface for easy use.
Navigate through the menu using the press keys to access functions such as:
- Alarmaufzeichnung: View past alarm events.
- Set L Alarm / Set H Alarm: Adjust low and high alarm thresholds for each gas.
- Nullpunkteinstellung: Calibrate the zero point for sensors (professional use recommended).
- Cali Gas: Perform gas calibration (professional use recommended).
- Zeit einstellen: Adjust the device's internal clock.
- Hintergrundbeleuchtung einstellen: Konfigurieren Sie die Einstellungen für die Hintergrundbeleuchtung.
- Passwort festlegen: Manage device access password.
- Kanalinfo: View information about sensor channels.
6. Wartung
6.1 Kalibrierung
While the MG-10 is factory calibrated, regular calibration is crucial for maintaining accuracy, especially for professional applications. Gas recalibration and zero adjustment should be performed by qualified professionals.
6.2 Reinigung
To ensure optimal performance and longevity, keep the device clean.
- Wischen Sie die Außenseite mit einem weichen,amp Tuch.
- Keine Scheuer- oder Lösungsmittel verwenden.
- Ensure the gas sensor area is free from dust and debris.
7. Fehlerbehebung
If you encounter issues with your MG-10 gas detector, consider the following general troubleshooting steps:
- Kein Strom: Stellen Sie sicher, dass der Akku vollständig geladen ist. Sollte das Problem weiterhin bestehen, wenden Sie sich bitte an den Support.
- Ungenaue Messwerte: Check if the sensor area is obstructed. Consider professional recalibration if readings remain inconsistent.
- Alarme funktionieren nicht: Verify alarm settings in the menu. Ensure volume and vibration are enabled.
- Gerät reagiert nicht: Try restarting the device. If it remains unresponsive, contact customer support.
8. Spezifikationen
| Besonderheit | Spezifikation |
|---|---|
| Modellnummer | MG-10 |
| Nachgewiesene Gase | H2S, O2, CO, EX (Combustible Gas) |
| Sensortyp | Electrochemical (for H2S, O2, CO) |
| Artikelgewicht | 260 g |
| Technische Daten | 13.97 x 7.62 x 3.81 cm |
| Batterie | 1 Lithium-Ionen-Akku (im Lieferumfang enthalten), 1800 mAh |
| Betriebsdauer | Over 8 hours (on full charge) |
| Stromquelle | Battery Powered (USB Recharge) |
| Farbe | Blau |
| Alarmtypen | Sound, Light (LED), Vibration |
| Luftfeuchtigkeit bei Betrieb | Bis zu 95 % (nicht kondensierend) |
| Obere Temperaturbewertung | 50 Grad Celsius |
| Spezifische Verwendungen | Professional gas monitoring |
9. Garantie und Support
MiLESEEY provides a 12 Monate Garantie for the MG-10 Gas Detector from the date of purchase. This warranty covers manufacturing defects and malfunctions under normal use.
For warranty claims, technical support, or any inquiries regarding your device, please contact MiLESEEY customer service. Please have your product model number (MG-10) and purchase details ready when contacting support.
Note: The warranty does not cover damage caused by misuse, unauthorized modifications, or improper maintenance.