1. Einleitung
This manual provides essential instructions for the safe and effective operation of your VOLTCRAFT RM-400 Geiger Counter. The RM-400 is designed for detecting Alpha, Beta, Gamma, and X-ray radiation, featuring high measurement accuracy, an internal memory for 4000 readings, a large LCD display, and Bluetooth connectivity for data evaluation. Please read this manual thoroughly before using the device.
2. Sicherheitshinweise
WARNUNG: To reduce the risk of injury, always read and understand the operator's manual before using this device.
- Ensure batteries are correctly installed before operation.
- Do not attempt to open or modify the device, as this may compromise its accuracy and safety features.
- Das Gerät sollte vor extremen Temperaturen, Feuchtigkeit und starken Magnetfeldern geschützt werden.
- This device is for informational and detection purposes. It is not a substitute for professional radiation safety equipment or expert advice.
- Batterien und Gerät sind gemäß den örtlichen Vorschriften zu entsorgen.
3. Produktüberschreitungview
The VOLTCRAFT RM-400 is a handheld Geiger counter designed for comprehensive radiation detection.

Abbildung 3.1: Schräg view of the VOLTCRAFT RM-400 Geiger Counter, highlighting the display and control buttons.
3.1 Gerätekomponenten
- Geiger-Müller Tube: Located at the top, responsible for detecting radiation.
- LCD Anzeige: Large screen for displaying measurement data, time, and settings.
- Bedientasten: For navigation, settings, saving data, and power.
- Batteriefach: Located at the rear for 4x 1.5V AA batteries.
- Bluetooth-Modul: For wireless data transfer to evaluation software.

Abbildung 3.2: Vorderseite view of the RM-400, showing the layout of the control buttons: SETUP, SAVE, SV/h R/h, Power, GPS/CAL/ML, ESC, and navigation arrows.

Abbildung 3.3: Rückseite view of the RM-400, indicating the battery compartment and safety warnings, including the requirement for 4x 1.5V AA batteries.
4. Einrichtung
4.1 Einlegen der Batterie
- Suchen Sie die Abdeckung des Batteriefachs auf der Rückseite des Geräts.
- Schieben oder lösen Sie die Abdeckung, um sie zu öffnen.
- Insert 4x 1.5V AA batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
- Bringen Sie den Batteriefachdeckel wieder fest an.
4.2 Erstes Einschalten
- Halten Sie die Leistung Drücken Sie die Taste, bis das Display aufleuchtet.
- The device will perform a self-test and then display the current radiation level.
- Adjust date, time, and other settings via the AUFSTELLEN menu if prompted or desired.
5. Bedienungsanleitung
5.1 Messungen durchführen
Once powered on, the RM-400 continuously monitors radiation levels.
- Echtzeitanzeige: The large LCD shows the current radiation dose rate (e.g., µSv/h).
- Radiation Types: The device detects Alpha, Beta, Gamma, and X-ray radiation. The specific detection mode or sensitivity may be adjustable in the SETUP menu.
- Akustische Warnung: The device emits an audible click for each detected radiation particle. An adjustable alarm threshold can be set to trigger a continuous warning sound when radiation levels exceed a predefined limit.

Figure 5.1: A user operating the RM-400 Geiger Counter, demonstrating its handheld use for radiation measurement in a controlled environment.
5.2 Datenprotokollierung und -speicherung
- The RM-400 has an internal memory capable of storing up to 4000 readings.
- Drücken Sie die SPEICHERN button to manually record the current measurement.
- Automatic logging intervals may be configured in the SETUP menu.
5.3 Bluetooth-Konnektivität
The device supports Bluetooth for transferring stored data to a computer or compatible mobile device for further analysis using the included evaluation software.
- Ensure Bluetooth is enabled on your RM-400 (check SETUP menu).
- Activate Bluetooth on your receiving device (computer/smartphone).
- Open the VOLTCRAFT evaluation software.
- Follow the software's instructions to pair with the RM-400 and download data.
6. Wartung
6.1 Reinigung
- Wischen Sie das Gerät mit einem weichen, trockenen Tuch ab.
- Keine Scheuer- oder Lösungsmittel verwenden.
- Achten Sie darauf, dass keine Flüssigkeiten in die Öffnungen des Geräts gelangen.
6.2 Speicherung
- Bewahren Sie das Gerät an einem kühlen, trockenen Ort ohne direkte Sonneneinstrahlung auf.
- Wenn das Gerät längere Zeit nicht verwendet wird, entfernen Sie die Batterien, um ein Auslaufen zu verhindern.
7. Fehlerbehebung
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Gerät lässt sich nicht einschalten. | Schwache oder leere Batterien; falsche Batterieinstallation. | Batterien austauschen; Batteriepolarität prüfen. |
| Ungenaue Messwerte. | Interference from other electronic devices; device malfunction. | Move away from potential interference sources; contact support if problem persists. |
| Die Bluetooth-Verbindung schlägt fehl. | Bluetooth not enabled on device or receiving unit; out of range. | Ensure Bluetooth is active on both devices; move closer; restart devices. |
| No acoustic warning. | Acoustic warning disabled; volume too low; alarm threshold not met. | Check settings in SETUP menu; adjust volume; verify radiation levels exceed threshold. |
8. Spezifikationen
| Modellname | VOLTCRAFT RM-400 Geiger Counter |
| Artikelmodellnummer | VC-12822170 |
| Strahlungsdetektion | Alpha, Beta, Gamma, X-rays |
| Interner Speicher | 4000 Lesungen |
| Anzeige | Großes LCD |
| Konnektivität | Bluetooth |
| Stromquelle | 4 x 1.5V AA-Batterien |
| Technische Daten | 14 x 18 x 31 cm |
| Artikelgewicht | 226 Gramm |
| Im Lieferumfang enthaltene Komponenten | Butter Paper (Note: This might be a translation error or packaging material. Refer to product packaging for exact contents.) |
| Spezifische Verwendungen | Radiation measurement, radiation detection, research, industrial, educational purposes |
9. Garantie und Support
For warranty information, technical support, or service inquiries, please refer to the documentation included with your product or visit the official VOLTCRAFT webBewahren Sie Ihren Kaufbeleg als Kaufnachweis auf.