1. Einleitung
The Xetron VGW-10X is a high-precision digital micron vacuum gauge designed for professional use in refrigeration and air conditioning systems. This device provides accurate deep vacuum measurements with a resolution of 1 micron across a wide range of 0 to 19,000 microns. Featuring Bluetooth connectivity, it allows for smart app control, data browsing, report export, and offline recording via your smartphone or tablet. The VGW-10X also includes functions for measuring ambient temperature and water saturation temperature, aiding in the assessment of H2O saturation. With eight selectable vacuum units and a long-lasting rechargeable lithium battery, the VGW-10X offers versatility and reliability for various applications. This manual provides detailed instructions for the proper setup, operation, and maintenance of your device.
2. Sicherheitshinweise
Please read all safety instructions carefully before operating the Xetron VGW-10X Digital Micron Vacuum Gauge. Failure to follow these instructions may result in injury or damage to the device.
- Always wear appropriate personal protective equipment (PPE) when working with refrigeration systems.
- Ensure the device is securely connected to the system before taking measurements.
- Setzen Sie das Gerät keinen extremen Temperaturen, direkter Sonneneinstrahlung oder korrosiven Umgebungen aus.
- Vermeiden Sie es, das Gerät fallen zu lassen oder starken Stößen auszusetzen.
- Halten Sie das Gerät von Wasser und Feuchtigkeit fern, um elektrische Gefahren zu vermeiden.
- Only use the provided charging cable and power adapter.
- Versuchen Sie nicht, das Gerät selbst zu zerlegen oder zu reparieren. Wenden Sie sich an den Kundendienst, um Hilfe zu erhalten.
3. Packungsinhalt
Bitte prüfen Sie, ob alle unten aufgeführten Artikel in Ihrem Paket enthalten sind. Sollten Artikel fehlen oder beschädigt sein, kontaktieren Sie bitte unseren Kundenservice.

Figure 3.1: Xetron VGW-10X Package Contents
- Vacuum meter x 1
- Metal fitting x 1
- Filter cotton x 3
- Benutzerhandbuch x 1
- O-Ring x 2
- Protective bag x 1
4. Produktüberschreitungview
Familiarize yourself with the components and display elements of the Xetron VGW-10X Digital Micron Vacuum Gauge.

Figure 4.1: Xetron VGW-10X Display Elements
| Nummer | Element | Funktion |
|---|---|---|
| 1 | Icon [REC] | Indicates when recording is enabled. |
| 2 | Staubsauger-Display | Shows the currently measured vacuum value. Units include microns, mTorr, inHg, Pa, Torr, kPa, mbar, psia. |
| 3 | Icon [Bluetooth] | Indicates an active Bluetooth connection. |
| 4 | Batteriesymbol | Displays the current battery capacity: >75%, >50%, >25%, >5%, <5%. |
| 5 | Temperaturanzeige | Shows the currently measured temperature. Parameters include TH2O (evaporation temperature of water), Tamb (ambient temperature), and ΔT (Tamb-TH2O). Units can be set to °C or °F. |
5. Einrichtung
Follow these steps for initial setup of your VGW-10X vacuum gauge.
- Laden Sie das Gerät auf: Before first use, fully charge the built-in lithium battery using the provided charging cable. A full charge can provide up to 20 hours of operation.
- Attach the Fitting: Screw the SAE 1/4" metal fitting onto the vacuum gauge securely. Ensure the O-ring is properly seated to prevent leaks.
- Einschalten: Press and hold the power button (usually located on the side or front) for a few seconds until the display illuminates.
- Einheitenauswahl: Briefly press the unit button (if available, or refer to the app for selection) to cycle through the available vacuum units (microns, mTorr, inHg, Pa, Torr, kPa, mbar, psia) and temperature units (°C/°F).
6. Bedienungsanleitung
This section outlines the basic operation of the vacuum gauge for taking measurements.

Figure 6.1: Clear LCD Screen Reading
- Mit System verbinden: Connect the vacuum gauge (with the attached fitting) to the vacuum pump or the system port where you intend to measure vacuum. Ensure all connections are tight to prevent leaks.
- Vakuumpumpe starten: Activate your vacuum pump to begin evacuating the system.
- Monitorwerte: The vacuum gauge will display real-time vacuum values. The response is fast and sensitive, allowing for precise monitoring of deep vacuum levels.
- Observe Temperature: The device also displays ambient temperature (Tamb) and water saturation temperature (TH2O), which can help in determining the presence of moisture in the system.
- Ausschalten: After completing your measurements, disconnect the gauge from the system and press and hold the power button to turn off the device.
7. Bluetooth-App-Steuerung
The Xetron VGW-10X can be connected to a smartphone or tablet via Bluetooth for enhanced monitoring and data management.

Figure 7.1: Xetron Mobile Application Interface
- Laden Sie die App herunter: Suchen nach the Xetron vacuum gauge app on the App Store (for iOS devices) or Google Play (for Android devices).
- Bluetooth aktivieren: Ensure Bluetooth is enabled on your smartphone or tablet and on the VGW-10X device.
- Mit Gerät verbinden: Open the app and follow the on-screen instructions to search for and connect to your VGW-10X. The Bluetooth icon on the gauge display will illuminate when connected.
- Monitordaten: The app allows you to browse real-time measurement data, view graphs, and monitor the progress of your vacuum process.
- Exportberichte: Generate and export measurement reports directly from your smartphone or tablet.
- Offline-Aufnahme: Utilize the offline recording function to log data even when not actively connected to the app, allowing for later review.
8. Erweiterte Funktionen
8.1. Understanding H2O Saturation
The VGW-10X can help assess the physical status of H2O in a cooling system by comparing ambient temperature and water saturation temperature.

Figure 8.1: H2O Status in Cooling System
By measuring both ambient temperature (Tamb) and the water saturation temperature (TH2O) corresponding to the vacuum level, the gauge can automatically determine if H2O is likely in a liquid or vapor state within the system. This feature is crucial for ensuring thorough dehydration during evacuation processes.
8.2. Temperaturkompensation
The device incorporates an advanced ambient compensating design to maintain accuracy across varying temperature conditions.

Figure 8.2: Temperature Compensation for Accuracy
This feature automatically compensates for temperature fluctuations, ensuring consistent and reliable vacuum measurements without the need for manual adjustments by the user.
9. Wartung
Proper maintenance ensures the longevity and accuracy of your Xetron VGW-10X.
- Reinigung: Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents. Ensure the sensor port is free of debris.
- Sensorschutz: Always keep the protective cap on the sensor port when the device is not in use to prevent contamination.
- O-Ringe: Regularly inspect the O-rings on the fitting for wear or damage. Replace them if necessary to maintain a leak-free connection.
- Batteriepflege: Laden Sie den Akku regelmäßig auf, auch wenn das Gerät nicht häufig benutzt wird, um seine Lebensdauer zu erhalten. Vermeiden Sie es, den Akku über längere Zeiträume vollständig zu entladen.
- Lagerung: Bewahren Sie das Gerät in der Schutzhülle an einem kühlen, trockenen Ort fern von direkter Sonneneinstrahlung und extremen Temperaturen auf.
10. Fehlerbehebung
In der folgenden Tabelle finden Sie häufig auftretende Probleme und deren mögliche Lösungen.
| Ausgabe | Mögliche Ursache | Lösung |
|---|---|---|
| Gerät lässt sich nicht einschalten. | Niedriger Batteriestand oder Gerätefehlfunktion. | Charge the device fully. If it still doesn't power on, contact customer support. |
| Inaccurate vacuum readings. | Sensor contamination, leaks in the system, or incorrect unit selection. | Ensure the sensor port is clean. Check all connections for leaks. Verify the correct vacuum unit is selected. |
| Die Bluetooth-Verbindung schlägt fehl. | Bluetooth not enabled, device out of range, or app issue. | Ensure Bluetooth is active on both devices. Move closer to the gauge. Restart the app and the gauge. |
| Vacuum decays rapidly after pump is off. | Leak in the system or gauge connection. | Perform a leak test on the entire system, including all connections to the gauge. Ensure O-rings are intact and fittings are tight. |
| Das Display ist dunkel oder flackert. | Schwache Batterie. | Laden Sie den Akku des Geräts auf. |
11. Spezifikationen
Technical specifications for the Xetron VGW-10X Digital Micron Vacuum Gauge.
| Parameter | Wert |
|---|---|
| Hersteller | Xetron |
| Modellnummer | VGW-10X |
| Produktreferenz | XT-VGW-10X-EU |
| Abmessungen (L x B x H) | 12.5 x 3.5 x 2.8 cm |
| Gewicht | 290 Gramm |
| Material | Metall |
| Vakuummessbereich | 0 bis 19,000 Mikrometer |
| Vacuum Resolution | 1 Mikron |
| Vakuumeinheiten | inHg, Torr, psia, mbar, mTorr, Pa, micron, kPa |
| Temperaturmessung | Ambient Temperature (Tamb), Water Saturation Temperature (TH2O) |
| Temperatureinheiten | ° C / ° F. |
| Konnektivität | Bluetooth Smart APP |
| Akku-Typ | Wiederaufladbare Lithiumbatterie (1 Stück enthalten) |
| Akkulaufzeit | Bis zu 20 Stunden (bei voller Ladung) |
| Beschlag | SAE 1/4" |
12. Garantie und Support
Xetron provides a one-year warranty for the VGW-10X Digital Micron Vacuum Gauge, covering manufacturing defects from the date of purchase. Additionally, we offer lifetime customer support to assist you with any questions or issues you may encounter.
For warranty claims, technical assistance, or any other inquiries, please contact Xetron customer support through the contact information provided on our official website or your purchase platform. Please have your product model number (VGW-10X) and purchase details ready when contacting support.