Satel AXD-200

Satel BE WAVE AXD-200 Multipurpose Detector User Manual

Model: AXD-200

1. Einleitung

The Satel BE WAVE AXD-200 is a wireless multipurpose detector designed for integration into home and apartment alarm systems. It functions as a window and door contact sensor, providing anti-burglary protection, and also includes a temperature sensor. This manual provides essential information for the proper installation, operation, and maintenance of your AXD-200 detector.

Satel BE WAVE AXD-200 Multipurpose Detector, showing the main unit and magnet component.

Figure 1: Satel BE WAVE AXD-200 Multipurpose Detector components.

2. Sicherheitshinweise

  • Lesen Sie alle Anweisungen vor der Installation und Verwendung sorgfältig durch.
  • This device is intended for outdoor use, but ensure it is protected from direct extreme weather conditions if possible.
  • Use only the specified battery type (1 CR123A Lithium-manganese dioxide). Incorrect battery types may cause damage or fire.
  • Versuchen Sie nicht, das Gerät selbst zu zerlegen oder zu reparieren. Wenden Sie sich an qualifiziertes Servicepersonal.
  • Keep the device away from strong magnetic fields, which can interfere with its operation.

3. Einrichtung

3.1 Auspacken und Komponenten

Prüfen Sie, ob alle Komponenten vorhanden sind:

  • AXD-200 Detector Unit
  • Magnetkomponente
  • Mounting Screws and Anchors (if included)

3.2 Einlegen der Batterie

  1. Open the detector casing vorsichtig.
  2. Insert one CR123A Lithium-manganese dioxide battery, observing the correct polarity (+/-).
  3. Schließen Sie den Detektor casing sicher.

3.3 Montage des Detektors

The AXD-200 detector consists of two parts: the main detector unit and a magnet. These parts must be mounted in close proximity to each other on a window or door frame and the moving part (window/door) respectively.

  1. Choose a suitable location on the window or door frame where the detector and magnet can be aligned when the window/door is closed. The gap between the two components should not exceed 1 cm (0.4 inches).
  2. Reinigen Sie die Montagefläche gründlich.
  3. Attach the main detector unit to the stationary part of the frame using the provided screws or adhesive strips.
  4. Attach the magnet component to the moving part of the window or door, ensuring it aligns with the marked area on the main detector unit when closed.
White Satel BE WAVE AXD-200 detector installed on a white door frame and door.

Abbildung 2: Bspample installation of the white AXD-200 detector.

Brown Satel BE WAVE AXD-200 detector installed on a wooden door frame and door.

Abbildung 3: Bspample installation of the brown AXD-200 detector.

3.4 Pairing with a Smart HUB

The AXD-200 detector requires a Satel Smart HUB or Smart HUB Plus for operation. Refer to your Smart HUB's manual for specific pairing instructions. Generally, this involves putting the HUB into pairing mode and then activating the detector (e.g., by opening/closing the contact or pressing a pairing button if available).

Satel Smart HUB device on a table next to a plant, indicating its necessity for the detector's operation.

Figure 4: A Satel Smart HUB is required for detector functionality.

3.5 App-Konfiguration

Once paired, use the dedicated Satel mobile application to configure the detector settings, view its status, and monitor temperature readings. The app allows you to customize notifications and integrate the detector into your overall security system.

Mobile application interface showing detector status, open/close events, and temperature readings.

Figure 5: Mobile application for configuration and monitoring.

4. Bedienung des Detektors

4.1 Door/Window Contact Function

The detector monitors the open/close status of the door or window it is installed on. When the magnet separates from the main unit (door/window opens), the detector sends a signal to the Smart HUB, triggering an alarm or notification according to your system's configuration.

4.2 Temperature Sensor Function

The integrated temperature sensor continuously monitors the ambient temperature at the detector's location. This data is transmitted to the Smart HUB and can be viewed via the mobile application. You may be able to set temperature thresholds for alerts within the app.

4.3 Tamper Schutz

The AXD-200 features tamper protection. If the detector casing is opened or forcibly removed from its mounting location, it will trigger a tamper alarm, enhancing the security of your system.

Illustration of tamper protection, showing an alarm icon and a hand attempting to pry open the detector.

Abbildung 6: Tamper protection mechanism.

5. Wartung

5.1 Batteriewechsel

When the battery level is low, your Smart HUB and mobile application will typically provide a notification. Replace the CR123A battery as described in Section 3.2. Always use a fresh, high-quality battery of the specified type.

5.2 Reinigung

Clean the exterior of the detector with a soft, dry cloth. Do not use abrasive cleaners, solvents, or excessive moisture, as these can damage the device.

5.3 Firmware-Updates

Periodically check the Satel mobile application or website for available firmware updates for your detector. Updates can improve performance, add features, or address security vulnerabilities. Follow the instructions provided by Satel for any update procedures.

6. Fehlerbehebung

  • Detektor reagiert nicht: Check battery level. Ensure the detector is within range of the Smart HUB. Re-pair the detector if necessary.
  • Fehlalarme: Verify the mounting alignment of the detector and magnet. Ensure the gap is not too wide. Check for any loose components or vibrations that might cause false triggers.
  • Temperature readings inaccurate: Ensure the detector is not exposed to direct sunlight or extreme heat/cold sources that do not reflect the ambient room temperature.
  • Verbindungsprobleme: Check the Smart HUB's status and Wi-Fi connection. Ensure there are no significant obstructions or interference sources between the detector and the HUB.

If issues persist, consult the Satel support webWebsite oder wenden Sie sich an den Kundendienst.

7. Spezifikationen

BesonderheitDetail
ModellnummerAXD-200
MarkeSatel
HerstellerSATEL sp. zoo
Abmessungen (L x B x H)25.4 x 5.08 x 6.86 cm (10 x 2 x 2.7 Zoll)
Gewicht80 Gramm (2.82 Unzen)
Akku-Typ1 x CR123A (Lithium-manganese dioxide)
Batterie im Lieferumfang enthaltenNEIN
Empfohlene VerwendungFor alarm systems
Innen-/AußenbereichIm Freien
Anzahl der Artikel im Paket1
UrsprungslandVereinigte Staaten von Amerika

8. Garantie und Support

For detailed warranty information, please refer to the official Satel webDie Website oder die Ihrem Produkt beiliegende Garantiekarte finden Sie hier. Bewahren Sie Ihren Kaufbeleg als Kaufnachweis auf.

For technical support, product inquiries, or service, please visit the official Satel support portal or contact their customer service department. Contact information can typically be found on the manufacturer's webWebsite.

Satel Official WebWebsite: www.satel.pl

Zugehörige Dokumente - AXD-200

Vorview SATEL AXD-200 PL Multipurpose Detector User Manual
User manual for the SATEL AXD-200 PL Multipurpose Detector, detailing its features, installation, testing, and technical specifications. This detector offers shock, opening, flood, temperature, and roller shutter detection capabilities, designed for use with the BE WAVE system.
Vorview Bedienungsanleitung für den drahtlosen Mehrzweckdetektor SATEL AXD-200
Dieses Handbuch enthält detaillierte Informationen zum drahtlosen Mehrzweckmelder SATEL AXD-200, einschließlich seiner Funktionen, technischen Daten, Installationsanleitung und Betriebsmodi. Es behandelt verschiedene Meldertypen wie Magnetkontakt-, Stoß-, Temperatur- und Wassermelder sowie festverdrahtete Zonenerweiterungen zur Verwendung mit ABAX 2- und ABAX-Systemen.
Vorview SATEL ABAX 2 Wireless Device Quick Installation Guide
Concise installation guide for SATEL ABAX 2 wireless devices, including models like ACD-220, ACMD-200, and AXD-200. Covers safety, battery handling, system integration, and signal testing for professional installers.
Vorview SATEL XD-2 Universaldetektor – Kurzanleitung zur Installation
A concise guide for the installation of the SATEL XD-2 universal detector, covering its functions as a magnetic contact, shock detector, and water flood detector. Includes wiring instructions and safety precautions.
Vorview Satel ASD-200 Wireless Smoke and Heat Detector Manual
Comprehensive manual for the Satel ASD-200 wireless smoke and heat detector, covering features, installation, maintenance, battery replacement, and specifications. Learn how to effectively use and maintain your fire detection device.
Vorview Benutzerhandbuch für den drahtlosen Rauch- und Wärmemelder SATEL ASD-200 SK
Ausführliche Bedienungsanleitung für den drahtlosen Rauch- und Wärmemelder SATEL ASD-200 SK. Erfahren Sie mehr über Funktionen, Installation, Bedienung, Wartung und technische Spezifikationen für eine zuverlässige Branderkennung.