VAXCEL T0697

VAXCEL T0697 Bronze Motion Sensor Outdoor Security Flood Light User Manual

Modell: T0697

Einführung

Thank you for choosing the VAXCEL T0697 Bronze Motion Sensor Outdoor Security Flood Light. This manual provides detailed instructions for the safe installation, operation, and maintenance of your new security light. Please read all instructions carefully before installation and retain this manual for future reference.

VAXCEL Bronze Motion Sensor Outdoor Security Flood Light installed on a house

Image: The VAXCEL Bronze Motion Sensor Outdoor Security Flood Light mounted on the exterior of a house, illuminating the area.

Sicherheitshinweise

Lieferumfang

Vergewissern Sie sich vor Beginn der Installation, dass alle Komponenten vorhanden sind:

Note: Light bulbs (2 x 150 watt PAR 38 medium base E26 screw-in bulbs) are not included. LED compatible.

Setup und Installation

This VAXCEL security light is designed for hardwired installation and can be mounted to a wall or eave. Ensure the mounting surface is structurally sound and capable of supporting the fixture's weight.

Montageoptionen

The fixture offers flexible mounting options, allowing for installation on either a wall or an eave. The light heads and motion sensor are adjustable to direct light where needed most.

Diagram showing wall mount and eave mount options for the flood light, with arrows indicating rotating light heads and sensor joint.

Image: A diagram illustrating the flexibility of the VAXCEL flood light, showing how it can be mounted on a wall or an eave, with arrows indicating the rotatable light heads and sensor joint for optimal positioning.

Verdrahtungsanweisungen

  1. Schalten Sie den Strom am Leistungsschalter oder Sicherungskasten ab.
  2. Attach the mounting bracket to the junction box using the provided hardware.
  3. Connect the fixture's wires to the household wiring: black to black (live), white to white (neutral), and green/bare copper to green/bare copper (ground). Secure connections with wire nuts.
  4. Stecken Sie alle Drähte vorsichtig in die Anschlussdose.
  5. Mount the fixture to the mounting bracket, ensuring a tight seal against the mounting surface to prevent water intrusion.
  6. Install two PAR38 E26 base bulbs (not included) into the sockets.
  7. Stellen Sie die Stromversorgung am Leistungsschalter wieder her.

Technische Daten

Technical drawing of the VAXCEL flood light with dimensions: A: 8 inches, B: 11-3/4 inches, C: 8-3/4 inches.

Image: A technical drawing providing the precise measurements of the VAXCEL flood light fixture, indicating its length, width, and height for installation planning.

Bedienungsanleitung

Your VAXCEL security flood light features advanced motion sensing and dusk-to-dawn capabilities, offering multiple modes for customized security and energy efficiency.

Diagram showing three light activation modes: Motion Sensor, Dusk to Dawn, and Switch Controlled.

Image: A visual representation of the three primary operational modes of the VAXCEL flood light: motion sensor activation, automatic dusk-to-dawn operation, and manual switch control.

Bewegungssensorfunktion

Diagram illustrating the 240-degree motion detection angle and 10-85 ft range, showing coverage around corners, flat walls, and inside corners.

Image: A graphic demonstrating the wide 240-degree detection angle and adjustable range (10-85 feet) of the motion sensor, highlighting its effectiveness in various outdoor settings including around corners and along walls.

Dusk-to-Dawn Photocell

The integrated photocell automatically turns the fixture on when it gets dark and off when it becomes light, providing continuous security and saving energy during daylight hours.

Dual-Level Brightness & Modes

Diagram showing customizable settings for the flood light, including motion shut-off delay, motion sensitivity, early evening timer, modes of operation, and dual-level brightness.

Image: A detailed graphic outlining the fully customizable settings of the VAXCEL flood light, including options for motion shut-off delay, sensitivity, early evening timer, various operating modes, and the dual-level brightness feature.

Wartung

Image of the VAXCEL flood light in rainy conditions, highlighting its outdoor durability and weather-resistant plastic material.

Image: The VAXCEL flood light shown enduring rain and snow, emphasizing its robust outdoor durability and weather-resistant construction.

Fehlerbehebung

ProblemMögliche UrsacheLösung
Licht geht nicht an.No power; faulty bulb; sensor malfunction.Check circuit breaker. Replace bulbs. Ensure sensor is clean and unobstructed.
Licht bleibt dauerhaft an.Sensor in test mode; continuous motion detected; wiring error.Check sensor mode. Remove obstructions. Verify wiring connections.
Licht blinkt oder flackert.Loose wiring; incompatible bulb; power fluctuations.Check all wiring connections. Use recommended bulbs. Consult an electrician if power issues persist.
Bewegungssensor erkennt nicht.Sensor obstructed; incorrect sensitivity setting; improper angle.Clear obstructions. Adjust sensitivity. Reposition sensor for optimal coverage.

Technische Daten

BesonderheitDetail
MarkeVAXCEL
ModellnameT0697
FarbeBronze
MaterialPlastik
Technische Daten8.75 Zoll L x 11.75 Zoll B x 8 Zoll H
Verwendung im Innen- und AußenbereichIm Freien
StromquelleFestverdrahtet
InstallationstypWall Mounted (also Eave Mount)
Besondere MerkmaleAdjustable Heads, Dusk to Dawn Sensor, Motion Sensor
Reichweite des Bewegungssensors240 Degree, 85 Ft.
LampensockelE26 Mittel
Wastage (maximal)2 x 150 watts (bulbs not included)
Bandtage120 Volt
WasserbeständigkeitWasserabweisend
ZertifizierungETL-gelistet

Garantie

This VAXCEL product comes with a limited warranty. Please refer to the warranty card included in your packaging for specific terms and conditions, or visit the VAXCEL webWebsite für weitere Informationen.

Produktvideo

Sehen Sie sich dieses Video für eine Weile anview of VAXCEL lighting products, showcasing various styles and applications.

Video: An informational video titled "About Vaxcel Lighting" providing a general overview of VAXCEL's lighting solutions.

Kundenservice

For further assistance, technical support, or warranty claims, please contact VAXCEL customer service. Contact information can typically be found on the VAXCEL webauf der Website oder auf der Produktverpackung.

Zugehörige Dokumente - T0697

Vorview Vaxcel T0804/T0805 Bewegungsmelder-Außenwandleuchte: Montage- und Installationsanleitung
Ausführliche Montage- und Installationsanleitung für die Vaxcel T0804 und T0805 Außenwandleuchten mit Bewegungsmelder. Erfahren Sie, wie Sie Ihre Leuchte installieren, bedienen und Fehler beheben.
Vorview Vaxcel T0804/T0805 Outdoor Motion Sensor Wall Sconce: Assembly & Installation Guide
Comprehensive assembly and installation instructions for the Vaxcel T0804 and T0805 outdoor motion sensor wall sconce. Covers features, operation modes, customization, troubleshooting, spare parts, and warranty.
Vorview Installations- und Montageanleitung für bewegungsaktivierte Lichter Vaxcel T0694/T0695
Diese Anleitung enthält detaillierte Anweisungen zur Installation und Bedienung der bewegungsaktivierten Außenleuchte Vaxcel T0694/T0695. Sie enthält wichtige Sicherheitsinformationen, Funktionen, Montageoptionen, Sensor- und Leuchtkopfeinstellungen, verschiedene Betriebsmodi, Tipps zur Fehlerbehebung und Garantiedetails.
Vorview Vaxcel T0739 Montage- und Installationsanleitung
Dieses Dokument enthält Montage- und Installationsanweisungen für die Vaxcel T0739-Leuchte. Es enthält eine Liste der Hardwarepakete, eine schrittweise Montageanleitung, Anweisungen zum optionalen Trennen der Fotozelle sowie Garantieinformationen.
Vorview Vaxcel T0571 Montage- und Installationsanleitung
Detaillierte Montage- und Installationsanleitung für die Außenleuchte Vaxcel T0571, einschließlich Hardwarelisten, Schaltplänen und Garantieinformationen.
Vorview Montage- und Installationsanleitung für die Außenwandleuchte Vaxcel T0633/T0634
Umfassende Anleitung zur Montage und Installation der Außenwandleuchten Vaxcel T0633 und T0634. Enthält Hardwaredetails, schrittweise Installation, optionale Fotozellentrennung, Ersatzteile und Abmessungen.