1. Einleitung
The Medela Harmony Manual Breast Pump is designed for occasional use, offering a convenient and discreet solution for milk expression. Its lightweight and portable design makes it ideal for travel or as a backup to an electric breast pump. This bundle includes PersonalFit Flex breast shields, engineered for enhanced comfort and optimized milk flow, aiming to provide more milk faster compared to traditional 90° breast shields.
This manual provides essential information for the safe and effective use, cleaning, and maintenance of your Medela Harmony Manual Breast Pump Bundle.

2. Lieferumfang
Your Medela Harmony Manual Breast Pump Bundle includes the following components:
- (1) Harmony Breast Pump: Consisting of the handle, diaphragm, and stem with o-ring.
- (1) 24mm PersonalFit Flex Breast Shield: Designed for comfort and efficient milk expression.
- (1) 5oz/150mL Breast Milk Bottle, Lid and Stand: For collecting and storing expressed milk.
- (1) Harmony Connector: Connects the breast shield to the pump mechanism.
- (1) Valve: Essential for creating suction.
- (1) Membrane: Works with the valve to regulate suction.
- Gebrauchsanweisung: Dieses Handbuch.
- Breastfeeding Information Guide: Additional resources for breastfeeding mothers.
- (2) PersonalFit Flex Replacement Membranes: Compatible with Medela electric pumps (Pump in Style MaxFlow, Swing Maxi, Freestyle Flex, Solo Breast Pumps).
- (2) PersonalFit Flex Replacement Connectors: Compatible with Medela electric pumps (Pump in Style MaxFlow, Swing Maxi, Freestyle Flex breast pumps).

3. Sicherheitshinweise
WICHTIG:
- Always read and follow all instructions carefully before first use and for subsequent uses.
- Ensure all pump parts are clean and sterilized before each use.
- Use only Medela authentic accessories and replacement parts designed for your specific breast pump model. Using incompatible parts may cause irreversible damage to the product and compromise its performance.
- Inspect all pump parts regularly for damage or wear. Replace damaged or worn parts immediately. Medela recommends replacing membranes every 3-6 months, depending on pumping frequency.
- This product is made without BPA, ensuring it is safe for you and your baby.

4. Einrichtung
Before assembling your Medela Harmony Manual Breast Pump, ensure all components have been thoroughly cleaned and sterilized according to the "Cleaning and Maintenance" section.
Montageschritte:
- Insert the valve and membrane into the Harmony Connector. Ensure the membrane lies flat against the valve.
- Attach the PersonalFit Flex Breast Shield to the Harmony Connector.
- Screw the assembled breast shield and connector onto the 5oz/150mL breast milk bottle.
- Attach the pump handle to the Harmony Connector. The handle should click securely into place.
- Place the bottle onto its stand for stability.

5. Bedienungsanleitung
The Medela Harmony Manual Breast Pump features two distinct pumping phases to mimic a baby's natural feeding rhythm: a stimulation phase and an expression phase.
Pumpvorgang:
- Positionierung: Center your nipple in the PersonalFit Flex Breast Shield tunnel. Ensure a comfortable seal around your breast.
- Stimulationsphase: Begin by pressing the smaller, upper part of the handle (the stimulation lever) quickly and lightly. This rapid, shallow suction helps stimulate milk let-down. Continue for approximately 2 minutes or until milk begins to flow.
- Ausdrucksphase: Once milk starts flowing, switch to the longer, lower part of the handle (the expression lever). Press this lever fully and hold for a few seconds, then release. This creates a slower, deeper suction to efficiently express milk. Adjust the rhythm and suction strength to your comfort and milk flow.
- Dauer: Pump until your breast feels soft and milk flow slows significantly. This typically takes 10-15 minutes per breast.
- Lagerung: After pumping, carefully remove the breast pump from your breast. Unscrew the bottle from the connector and seal it with the provided lid for storage.

6. Reinigung und Wartung
Proper cleaning and maintenance are crucial for hygiene and the longevity of your breast pump. All parts that come into contact with breast milk should be cleaned after each use and sterilized daily.
Nach jedem Gebrauch:
- Alle Teile, die mit Muttermilch in Berührung kommen (Brusthütchen, Konnektor, Ventil, Membran, Flasche), müssen demontiert werden.
- Rinse all separated parts with cold water to remove milk residue.
- Wash parts in warm, soapy water using a mild dish soap. Use a clean brush dedicated for pump parts.
- Mit klarem Wasser gründlich abspülen.
- Air dry on a clean paper towel or drying rack. Avoid using a cloth towel as it may leave lint.
Daily Sterilization:
In addition to washing, sterilize all milk-contacting parts once a day:
- Kochen: Place disassembled parts in a pot of boiling water for 5 minutes. Ensure parts do not touch the bottom of the pot to prevent damage.
- Spülmaschine: All components are dishwasher safe. Place parts on the top rack of your dishwasher.
- Dampfsterilisation: Use a microwave steam sterilizer bag or unit according to its instructions.
Um Bakterienwachstum zu verhindern, muss sichergestellt werden, dass alle Teile vor dem Zusammenbau oder der Lagerung vollständig trocken sind.

7. Fehlerbehebung
If you encounter issues with your Medela Harmony Manual Breast Pump, refer to the following common solutions:
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Keine oder geringe Saugkraft | Improper assembly; damaged/worn membrane or valve; breast shield not sealed properly. | Ensure all parts are assembled correctly and securely. Check membrane and valve for tears or damage and replace if necessary. Reposition breast shield for a tight seal. |
| Die Milch fließt nicht. | Not enough stimulation; incorrect pumping rhythm; engorgement. | Start with the stimulation phase (quick, light pumps). Adjust to a slower, deeper rhythm for expression. Apply warm compresses or massage breasts before pumping if engorged. |
| Schmerzen oder Beschwerden | Incorrect breast shield size; excessive suction; improper nipple alignment. | Ensure your nipple is centered and moves freely in the tunnel. Consult a lactation consultant for proper breast shield sizing. Reduce suction intensity. |
8. Spezifikationen
- Marke: Medela
- Modell: Harmonie
- Betriebsmodus: Handbuch
- Breast Shield Size: 24mm PersonalFit Flex (included)
- Flaschenkapazität: 5 Unzen / 150 ml
- Material: BPA-frei
- Spülmaschinenfest: Ja
- Zusätzliche Funktionen: Leicht, tragbar
9. Garantie und Support
For warranty information, product support, or to purchase additional parts and accessories, please visit the official Medela webBesuchen Sie die Website oder kontaktieren Sie direkt den Medela-Kundendienst. Bewahren Sie Ihren Kaufbeleg für Garantieansprüche auf.
Medela Official WebWebsite: www.medela.com
Rückgaberecht: This product has a 90-day refund/replacement return policy when purchased from Amazon.