1. Wichtige Sicherheitshinweise
Please read this manual thoroughly before installation and operation. Keep this manual for future reference. Improper installation or operation may cause serious injury or property damage.
- Professionelle Installation erforderlich: This unit requires professional installation by a qualified HVAC technician. Attempting self-installation without proper training and tools can lead to electric shock, fire, water leakage, or other hazards.
- Elektrische Sicherheit: Ensure the power supply matches the unit's requirements (220V). Do not operate with damaged power cords or plugs. Always disconnect power before servicing.
- Umgang mit Kältemitteln: This unit contains R-410A refrigerant. Handling of refrigerant should only be performed by certified personnel.
- Spielraum: Für eine ordnungsgemäße Luftzirkulation und Wartung muss um die Innen- und Außengeräte herum ausreichend Platz vorhanden sein.
- Kinder und Haustiere: Halten Sie Kinder und Haustiere während des Betriebs und der Wartung vom Gerät fern.
2. Produktüberschreitungview
The ApooDr AES Series Mini Split Air Conditioner is a ductless inverter system designed for efficient cooling and heating. This 18,000 BTU unit features a 19 SEER2 rating, a heat pump function, and Wi-Fi connectivity for smart control.
Schlüsselkomponenten:
- Innenluftbehandlungsgerät
- Außenkondensator
- Fernbedienung
- 16 ft Line Set (for installation)
- Installations- und Benutzerhandbuch

Abbildung 2.1: Überview of the ApooDr Mini Split Air Conditioner system, showing both indoor and outdoor units.
3. Einrichtung und Installation
Wichtig: Installation of this mini split system must be performed by a certified HVAC professional. This ensures proper function, safety, and warranty validity.
3.1 Prüfungen vor der Installation:
- Stromversorgung prüfen (220 V).
- Ensure adequate space for both indoor and outdoor units.
- Confirm the 16 ft line set is sufficient for the desired distance between units.
3.2 WLAN-Einrichtung:
The unit is Wi-Fi enabled, allowing control via a smartphone app and voice commands through Alexa. Refer to the separate Wi-Fi setup guide included with your unit for detailed instructions on connecting to your home network and integrating with smart home systems.

Figure 3.1: The mini split unit supports Wi-Fi control via a smartphone app and AI voice control, indicated by a USB-WIFI dongle and a smart speaker icon.
4. Bedienungsanleitung
The ApooDr Mini Split offers various modes and features for optimal comfort. All functions can be controlled via the included remote control.
4.1 Fernbedienungsfunktionen:
The remote control allows you to adjust temperature, fan speed, operating mode, and other settings. The unit's digital display shows the current temperature.
- EIN/AUS: Schaltet das Gerät ein oder aus.
- MODUS: Durchläuft verschiedene Betriebsmodi (Kühlen, Heizen, Lüfter, Entfeuchten, Automatik).
- TEMP +/-: Regelt die gewünschte Temperatur.
- VENTILATOR: Ändert die Lüftergeschwindigkeit (Auto, Niedrig, Mittel, Hoch).
- SCHWINGEN: Activates or deactivates the automatic louver swing for air distribution.
- SCHLAFEN: Optimizes settings for comfortable sleep.
- TURBO: Sorgt für schnelle Kühlung oder Erwärmung.
- SAUBER: Initiates the self-cleaning function.
- LEDs: Schaltet die Display-LED ein oder aus.
- FOLGEN SIE MIR: Activates a sensor in the remote to measure temperature at its location.
4.2 Air Distribution:
The unit features advanced air supply patterns for enhanced comfort:
- Kühlmodus: Shower-style air supply directs cool air downwards.
- Heizbetrieb: Blanket-style air supply directs warm air along the floor.

Figure 4.1: The indoor unit distributes air differently based on the operating mode: shower-style for cooling and blanket-style for heating.
4.3 Performance Capabilities:
This inverter system provides robust performance across a wide range of outdoor temperatures:
- Starke Kühlung: Effective cooling up to 140°F (60°C) ambient temperature.
- Strong Heating: Reliable heating down to -13°F (-25°C) ambient temperature.

Figure 4.2: The unit maintains strong cooling performance even at high ambient temperatures (e.g., 131°F) and strong heating performance in low ambient temperatures (e.g., -13°F).
4.4 Quiet Operation:
The unit is designed for quiet operation, with indoor noise levels as low as 31 dB and outdoor noise levels at 52 dB.

Figure 4.3: The unit operates quietly, with noise levels as low as 22dB, and offers multiple vertical and horizontal air blow types for precise air distribution.
5. Wartung
Regelmäßige Wartung gewährleistet optimale Leistung und Langlebigkeit Ihrer Mini-Split-Klimaanlage.
5.1 Self-Cleaning and Sterilization:
The unit features a 133°F (56°C) high-temperature self-cleaning and sterilization function. This process involves frosting, defrosting, high-temperature drying, and sterilization to inhibit bacterial growth.

Figure 5.1: The self-cleaning process includes frosting, defrosting, high-temperature drying, and 133°F sterilization, which has been tested to achieve up to 93.18% bacterial killing rate.
5.2 Filterreinigung:
Clean the air filters regularly (every 2-4 weeks, depending on usage) to maintain airflow and efficiency. Refer to the detailed instructions in the full manual for filter removal and cleaning procedures.
5.3 Professionelle Wartung:
Schedule annual professional maintenance to check refrigerant levels, clean coils, and inspect all components for optimal performance and to prevent potential issues.
6. Fehlerbehebung
If you encounter issues with your unit, refer to the following common troubleshooting steps. For complex problems, contact a qualified technician.
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Das Gerät lässt sich nicht einschalten | Kein Strom, Batterien der Fernbedienung leer, Sicherung ausgelöst. | Stromversorgung prüfen, Batterien der Fernbedienung austauschen, Sicherungsautomat zurücksetzen. |
| Unzureichende Kühlung/Heizung | Verschmutzte Luftfilter, blockiertes Außengerät, falsche Betriebsart eingestellt, zu wenig Kältemittel. | Clean filters, clear obstructions, select correct mode, contact technician for refrigerant check. |
| Ungewöhnliche Geräusche | Lose Teile, Lüfterblockade, Kältemittelströmungsgeräusche (normal). | Inspect for loose parts, remove obstructions, consult manual for normal operating sounds. |
| Wasserleck | Verstopftes Abflussrohr, unsachgemäße Installation. | Clear drain pipe, contact professional for inspection. |
| Probleme mit der Wi-Fi-Konnektivität | Routerprobleme, falsche WLAN-Einstellungen, App-Fehlfunktion. | Restart router, reconfigure Wi-Fi settings in app, reinstall app. |
7. Spezifikationen
| Besonderheit | Spezifikation |
|---|---|
| Marke | Abonnieren |
| Modellnummer | AES19-18H1B |
| Kapazität | 18,000 BTU (1.5 Tonnen) |
| SEER-Bewertung | 19.0 |
| Bandtage | 220 Volt |
| Wastage | 1800 Watt |
| Artikelgewicht | 110 Pfund |
| Technische Daten | 8.66"T x 39.76"B x 12.4"H |
| Geräuschpegel (Innenbereich) | 31 Dezibel |
| Installationstyp | Geteiltes System |
| Kältemittel | Pre-Charged R-410A |
| Besondere Merkmale | 4 Way Swing, Dehumidifier, Fast Cooling, Inverter Compressor, WiFi Enabled |
| Im Lieferumfang enthaltene Komponenten | Indoor unit, outdoor unit, remote control, line set, Installation and User Manual |
8. Garantie und Support
For warranty information, technical support, or service requests, please refer to the warranty card included with your product or contact ApooDr customer service. Ensure you have your model number (AES19-18H1B) and purchase date available when contacting support.