1. Einführung und Endeview
The INKBIRDPLUS PTH-10C Portable CO2 Detector is designed to monitor carbon dioxide levels in various indoor environments. It features an advanced Non-Dispersive Infrared (NDIR) sensor for high-precision detection, a large color LCD screen for clear readings, and an audible alarm system. Its compact and portable design, coupled with a long-lasting rechargeable battery, makes it suitable for use in homes, offices, grow tents, greenhouses, and other spaces where air quality monitoring is essential.

Image: The INKBIRDPLUS PTH-10C Portable CO2 Detector on a desk, displaying CO2 levels.
2. Produktmerkmale
- High-Precision NDIR Sensor: Utilizes advanced infrared technology for accurate CO2 detection.
- Doppelte Alarmfunktion: Features visual (tri-color indicator) and audible alarms with customizable thresholds.
- Tragbares und robustes Design: Compact size with an included lanyard for easy carrying.
- Großer Farb-LCD-Bildschirm: Provides clear and easy-to-read CO2 concentration values.
- ECO-Energiesparmodus: Automatically turns off the screen after 5 minutes of inactivity to conserve battery.
- Langlebige Batterie: Built-in 1000mAh lithium battery offers up to 72 hours of operation.
- USB-C wiederaufladbar: Convenient charging via a standard USB-C port.
- Automatic and Manual Calibration: Ensures measurement accuracy over time.

Bild: Überview of the detector's main features, including NDIR sensor, LCD, alarm, ECO mode, calibration, and USB charging.
3. Packungsinhalt
Bitte prüfen Sie das Paket auf folgende Artikel:
- 1 x INKBIRDPLUS PTH-10C Portable CO2 Detector
- 1 x USB-C Ladekabel
- 1 x Schlüsselband.
- 1 x Benutzerhandbuch
4. Gerätelayout
The device features a simple and intuitive design. The main display shows CO2 concentration, battery status, and alarm indicators. A single multi-function button controls various settings and calibration.

Bild: Vorderseite view of the INKBIRDPLUS CO2 detector highlighting its main features.
5. Einrichtung
- Erstladung: Before first use, fully charge the device using the provided USB-C cable and a compatible 5V USB power adapter. The battery indicator on the screen will show charging status. A full charge typically takes about 3 hours.
- First Use Calibration: For optimal accuracy, it is highly recommended to perform a manual calibration in an open, unpopulated environment with fresh air (e.g., outdoors) during the first use. Refer to Section 7 for calibration instructions.
6. Bedienung
6.1 Ein-/Ausschalten
Press and hold the multi-function button for approximately 3 seconds to power the device on or off.
6.2 Ablesen des Displays
The large color LCD screen displays the current CO2 concentration in parts per million (ppm). The device also features a tri-color indication light system around the display to quickly assess air quality:
- Grünes Licht: 400-699 ppm (Good concentration)
- Gelbes Licht: 700-1499 ppm (Medium concentration)
- Rotlicht: 1499-5000 ppm (Dangerous concentration)

Image: Explanation of the tri-color CO2 indication light system.
6.3 ECO Power-Saving Mode
To conserve battery, the device automatically enters ECO power-saving mode after 5 minutes of inactivity, turning off the screen. The device continues to monitor CO2 levels in the background. Press any button to reactivate the display.
7. Kalibrierung
Calibration ensures the accuracy of your CO2 detector. The device supports both automatic and manual calibration.
7.1 Automatische Kalibrierung
Automatic calibration is enabled by default. The device will periodically self-calibrate in environments with stable CO2 levels. You can manually toggle automatic calibration on or off.

Image: Instructions for toggling automatic calibration (C-ON/C-OF).
7.2 Manuelle Kalibrierung
So führen Sie eine manuelle Kalibrierung durch:
- Place the device in an open, unpopulated environment with fresh air (e.g., outdoors) for at least 10-15 minutes to allow CO2 levels to stabilize.
- Long press the multi-function button. The screen will display "CAL" and initiate a 200-second countdown.
- Keep the device in the fresh air environment until the countdown completes. The device will then be calibrated.

Image: Steps for initiating manual calibration.
8. Alarmeinstellungen
The device is equipped with an audible alarm that activates when the CO2 concentration exceeds a set threshold. The default alarm threshold is 1500 ppm.
8.1 Customizing the Alarm Value
To adjust the alarm threshold:
- Long press the multi-function button for approximately 5 seconds until the alarm value starts flashing.
- Press the button once to increment the flashing digit.
- Press the button twice quickly to move to the next digit.
- Once the desired alarm value is set, wait a few seconds for the device to save the setting automatically.
8.2 Deactivating the Alarm
The audible alarm function can be deactivated if desired. Follow the steps for customizing the alarm value and set it to 'OFF' or a similar indicator if available, or set the threshold to its maximum value (5000 ppm) to effectively disable it for typical indoor use.

Image: Illustration of the smart CO2 alarm in action.
9. Energieverwaltung
The PTH-10C is powered by a built-in 1000mAh lithium-polymer battery.
9.1 Akkulaufzeit
A fully charged battery provides up to 72 hours of continuous operation. Actual battery life may vary depending on usage patterns and environmental conditions.

Image: Illustration of the 1000mAh lithium battery and its 72-hour endurance.
9.2 Laden
Connect the device to a 5V USB power source using the provided USB-C cable. The battery icon on the display will indicate charging status. The device can be used while charging.
10. Wartung
- Reinigung: Wipe the device with a soft, dry cloth. Do not use liquid cleaners, abrasive materials, or solvents, as these can damage the sensor or casing.
- Lagerung: Store the device in a cool, dry place away from direct sunlight, extreme temperatures, and high humidity when not in use for extended periods.
- Kalibrierung: Regular calibration (as described in Section 7) is recommended to maintain measurement accuracy.
11. Fehlerbehebung
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Ungenaue CO2-Messwerte | Sensor drift; device not calibrated; sensor obstructed. | Perform a manual calibration in a fresh air environment. Ensure the sensor opening is clear. |
| Gerät lässt sich nicht einschalten | Batterie ist leer. | Laden Sie das Gerät mit dem USB-C-Kabel auf. |
| Der Alarm ertönt nicht | Alarm function deactivated; alarm threshold set too high. | Check alarm settings (Section 8) and ensure it is enabled and the threshold is appropriate. |
| Kurze Akkulaufzeit | Battery not fully charged; frequent screen activation. | Ensure the device is fully charged. Utilize ECO power-saving mode. |
12. Spezifikationen
| Parameter | Wert |
|---|---|
| Modellnummer | PTH-10C |
| Hersteller | INKBIRDPLUS |
| Abmessungen (L x B x H) | 7 x 7 x 2.5 cm (2.75 x 2.75 x 0.98 Zoll) |
| Gewicht | 20 Gramm (0.7 Unzen) |
| Akku-Typ | 1000mAh Lithium-Polymer-Akku (im Lieferumfang enthalten) |
| Stromquelle | Battery powered, USB-C rechargeable |
| Bandtage | 5 Volt |
| Material | Plastik |
| Sensortyp | Nicht-dispersives Infrarot (NDIR) |
| Alarmtyp | Hörbar |
| CO2-Erkennungsbereich | 400-5000 ppm |
| Ladezeit | Ungefähr 3 Stunden |
| Betriebsdauer | Bis zu 72 Stunden |
13. Sicherheitshinweise
- Setzen Sie das Gerät nicht Wasser oder übermäßiger Feuchtigkeit aus.
- Do not disassemble or attempt to repair the device. Unauthorized repairs will void the warranty.
- Außerhalb der Reichweite von Kindern aufbewahren.
- Verwenden Sie zum Aufladen ausschließlich das mitgelieferte oder ein zertifiziertes USB-C-Kabel.
- This device is intended for general air quality monitoring and should not be used as a substitute for professional medical advice or certified safety equipment in critical environments.
- Avoid placing the device in direct sunlight or near heat sources, as this may affect sensor accuracy.
14. Garantie und Support
For detailed warranty information, technical support, or customer service inquiries, please visit the official INKBIRDPLUS website or contact their customer support team directly. Please have your model number (PTH-10C) and purchase information ready when contacting support.