The FireAngel FA6813 Carbon Monoxide (CO) Detector is designed to provide early warning of dangerous carbon monoxide levels in your home. This device utilizes an advanced electrochemical sensor to accurately detect CO gas, which is colorless, odorless, and highly toxic. It is a crucial safety device for any household.

This model is designed to replace previous FireAngel CO-9B and CO-9X models, offering enhanced features and reliability. It is powered by 2 AA batteries, ensuring continuous operation even during power outages.

FireAngel FA6813 Carbon Monoxide Detector front view

Abbildung 1: Vorderseite view of the FireAngel FA6813 Carbon Monoxide Detector.

FireAngel FA6813 Carbon Monoxide Detector with packaging highlighting features

Figure 2: The FA6813 detector with its packaging, emphasizing its 10-year sensor life, 85 dB(A) alarm, and included AA batteries.

2. Wichtige Sicherheitshinweise

WARNING: This device detects carbon monoxide gas. It is not designed to detect smoke, fire, or other gases. Carbon monoxide is a silent killer; it is invisible, odorless, and potentially fatal.

In Case of a CO Alarm:

  1. Lüften: Immediately open all doors and windows to air out the premises. Turn off all combustion appliances (e.g., furnaces, water heaters, gas stoves).
  2. Evakuieren: Leave the building immediately. Ensure everyone, including pets, is out of the affected area.
  3. Call for Help: From a safe location outside the building, contact your gas supplier or emergency services. Do not re-enter the premises until it has been declared safe by a qualified professional.
  4. Nicht wiederverwenden: Do not use any combustion appliances again until they have been inspected and verified safe by a qualified technician.
FireAngel FA6813 Carbon Monoxide Detector side view with safety information

Abbildung 3: Seite view of the FA6813, emphasizing its role in domestic safety and the properties of carbon monoxide.

3. Packungsinhalt

Bitte kreuzen Sie das Kästchen an, um sicherzustellen, dass alle Komponenten vorhanden sind:

  • FireAngel Carbon Monoxide Alarm (FA6813)
  • 2 x AA-Batterien
  • Bedienungsanleitung

4. Einrichtung und Installation

4.1 Einlegen der Batterie

The FA6813 detector operates on 2 AA batteries. These are included in the package. To install:

  1. Suchen Sie das Batteriefach auf der Rückseite des Geräts.
  2. Öffnen Sie die Fachabdeckung.
  3. Legen Sie die 2 AA-Batterien ein und achten Sie dabei auf die richtige Polarität (+ und -).
  4. Schließen Sie den Batteriefachdeckel fest.

4.2 Aufstellung und Montage

The FA6813 is designed for versatile placement, suitable for both home use and travel. It can be wall-mounted or placed freestanding on a flat surface.

  • Wandmontage: The device comes with an integrated mounting bracket and screws. Choose a location according to local regulations and manufacturer guidelines (typically near combustion appliances but not directly above them, and at breathing height). Mark the screw positions, drill pilot holes, insert wall plugs if necessary, and secure the bracket. Slide the detector onto the bracket.
  • Freistehend: For portable use or temporary placement, the detector can stand on its own. Place it on a stable, flat surface where it will not be easily knocked over.
FireAngel FA6813 Carbon Monoxide Detector in a travel setting

Figure 4: The FA6813 detector shown in a travel context, highlighting its portability and integrated mounting support for optional wall installation.

5. Bedienungsanleitung

5.1 Normalbetrieb

Once batteries are installed, the device will perform a self-test and then enter normal monitoring mode. A small LED indicator may flash periodically to confirm it is active and monitoring.

5.2 Test Button Functionality

The large test button on the front of the detector serves multiple purposes:

  • Sicherheitstest: Press the test button briefly to verify the proper functioning of the detector. A loud, sharp audible signal and 4 flashes of the red LED will confirm the alarm is working correctly. Perform this test regularly (e.g., weekly or monthly).
  • Sound Level Adjustment (Sound Test): Hold the test button down to cycle through different sound levels for the test alarm, allowing you to choose a comfortable volume.

5.3 Alarmanzeigen

When dangerous levels of carbon monoxide are detected, the FA6813 will alert you with:

  • Hörbarer Alarm: 4 loud beeps (85 dB(A) at 3 meters).
  • Visueller Alarm: A flashing red "CO" LED indicator.

5.4 Low Battery Indication and Sleep Easy™ Function

When the batteries are low, the device will indicate this with:

  • Visuelle Anzeige: A flashing orange "!" LED symbol.
  • Audible Indication: An audible beep.

To temporarily silence the low battery alert for 8 hours, press the test button. This activates the Sleep Easy™ mode, allowing you to silence the low battery beep, while the orange LED continues to flash as a reminder to replace the batteries.

FireAngel FA6813 Carbon Monoxide Detector with batteries and box

Figure 5: The FA6813 detector with its components, illustrating the advanced electrochemical sensor, Sleep Easy™ function, LED indicators, and sound ampVerifizierungsfunktion.

6. Wartung

6.1 Batteriewechsel

When the low battery indicator (flashing orange LED and beep) activates, it is time to replace the batteries. Follow the battery installation steps outlined in Section 4.1. Always use new, high-quality AA alkaline batteries.

6.2 Regelmäßige Tests

It is crucial to test your CO detector regularly, at least once a week or monthly, by pressing the test button. This ensures the alarm and its internal circuitry are functioning correctly.

6.3 Reinigung

Clean the exterior of the detector periodically with a soft, damp cloth. Do not use cleaning solvents or polishes, as these can damage the unit or interfere with the sensor's operation. Do not paint the unit.

7. Fehlerbehebung

ProblemMögliche UrsacheLösung
Alarm sounds (4 beeps, red LED)Carbon monoxide detected.Follow the "In Case of a CO Alarm" procedure (Section 2). Do not ignore the alarm.
Orange LED flashes and unit beeps periodicallyWarnung bei niedrigem Batteriestand.Replace both AA batteries immediately. Use the Sleep Easy™ function if needed to silence for 8 hours.
Test button does not activate alarmBatteries are dead or incorrectly installed; unit malfunction.Check battery installation and replace if necessary. If problem persists, the unit may need replacement.
Gerät lässt sich nicht einschaltenDie Batterien sind leer oder falsch eingelegt.Ensure batteries are new and inserted with correct polarity.

8. Spezifikationen

BesonderheitDetail
ModellnummerFA6813-EUX10
HerstellerFeuerengel
Abmessungen (L x B x H)12.3 x 7.3 x 3.55 cm (approx. 5 x 12.3 x 8 cm from other spec)
Gewicht141 Gramm
FarbeWeiß
Stromquelle2 x AA-Alkalibatterien (im Lieferumfang enthalten)
SensortypElektrochemisch
Alarmlautstärke85 dB(A) bei 3 Metern
Luftfeuchtigkeit bei Betrieb25 bis 95% relative Luftfeuchtigkeit
Lebensdauer des Sensors10 Jahre
FireAngel FA6813 Carbon Monoxide Detector with dimensions

Figure 6: The compact design of the FA6813, illustrating its dimensions and weight.

9. Garantie und Support

FireAngel is committed to providing high-quality safety products. For any questions, technical assistance, or warranty claims, please contact your supplier or refer to the FireAngel official webWebsite für Supportinformationen.

Regular maintenance and adherence to the instructions in this manual will help ensure the longevity and proper functioning of your CO detector.

FireAngel brand image with a person looking up

Figure 7: FireAngel's commitment to protecting and improving lives through advanced and innovative technology.

Zugehörige Dokumente - FA6813-EUX10

Vorview FireAngel FA6813 Kohlenmonoxidmelder Benutzerhandbuch
Umfassendes Benutzerhandbuch für den Kohlenmonoxidmelder FireAngel FA6813 mit Informationen zu Installation, Betrieb, Wartung, Fehlerbehebung und Sicherheit.
Vorview FireAngel FA6812/FA6813 Kohlenmonoxidmelder – Benutzerhandbuch
Benutzerhandbuch für die Kohlenmonoxid-Melder FireAngel FA6812 und FA6813, mit Anweisungen zur Installation, Bedienung, Sicherheit und Wartung.
Vorview FireAngel SCB10 Kombinierter Rauch- und Kohlenmonoxidmelder – Benutzerhandbuch
Benutzerhandbuch für den FireAngel SCB10, einen kombinierten Rauch- und Kohlenmonoxidmelder, mit umfassenden Anweisungen zu Installation, Betrieb, Wartung und Sicherheit für den privaten Gebrauch.
Vorview FireAngel CO-9X 7 Jahre Lebensdauer Kohlenmonoxidmelder Benutzerhandbuch
Ausführliches Benutzerhandbuch für den Kohlenmonoxid-Giftgasmelder FireAngel CO-9X mit 7-jähriger Lebensdauer. Erfahren Sie mehr über Installation, Betrieb, Wartung, Sicherheit und Fehlerbehebung.
Vorview FireAngel Multisensor Plus Benutzerhandbuch: Rauch-, Wärme- und CO-Melder
Ausführliches Benutzerhandbuch für FireAngel Multisensor Plus und Multisensor Plus Kitchen mit detaillierten Informationen zu Installation, Bedienung, Sicherheit, Fehlerbehebung und technischen Spezifikationen für die Rauch-, Wärme- und Kohlenmonoxiderkennung.
Vorview FireAngel CO-Melder FA3313, FA3322, FA3328, FA3820 Benutzerhandbuch
Umfassende Bedienungsanleitung für FireAngel Kohlenmonoxidmelder (Modelle FA3313, FA3322, FA3328, FA3820) mit Informationen zu Positionierung, Installation, CO-Alarmerkennung, Wartung, Statusanzeigen, Sleep-Easy-Funktion, LCD-Bildschirmanzeigen und technischen Daten. Enthält Informationen zu Garantie und Entsorgung.