1. Einleitung
The UNI-T UT202R is a high-precision digital clamp meter designed for accurate electrical measurements. It features automatic ranging, True RMS capabilities, and a clear LCD backlight display. This manual provides essential information for the safe and effective operation of your device.
2. Sicherheitshinweise
Always adhere to local and national safety codes. Use appropriate personal protective equipment (PPE) such as insulated gloves and eye protection. Do not attempt to measure voltages or currents exceeding the specified maximum ratings. Ensure the device is in good working condition before use. Refer to the safety markings on the device and in the full product documentation.
- CAT III 300V / CAT II 600V: Indicates the measurement category and maximum voltage für einen sicheren Betrieb.
- Bei Beschädigung nicht verwenden: Inspect the meter and test leads for any damage before each use.
- Vermeiden Sie nasse Bedingungen: Do not operate the meter in wet environments.
- Batteriesicherheit: Ersetzen Sie die Batterien, wenn die Anzeige für niedrigen Batteriestand erscheint.
3. Produktüberschreitungview
3.1. Komponenten

Bild: Detailliert view of the UNI-T UT202R Digital Clamp Meter with labels pointing to its various parts, including the clamp head, NCV sensor, NCV warning lamp, function turntable, function switch button, LED display, relative value button, Max/Min button, data hold/backlight button, black probe socket, and red probe socket.
- Clamp Kopf: Wird zur berührungslosen Strommessung verwendet.
- NCV-Sensor: Kontaktloses Volumentage Erkennung.
- NCV Warning Lamp: Illuminates during NCV detection.
- Tong Head Trigger: Öffnet den Verschlussamp Kiefer.
- Function Turntable (Dial): Wählt Messmodi aus.
- Function Switch Button (SELECT): Toggles between functions within a dial setting.
- LED-Anzeige: High-definition display for measurement readings.
- REL/Zero Button: For relative measurement or zeroing.
- MAX/MIN-Taste: Speichert Maximal- und Minimalwerte.
- HOLD-/Hintergrundbeleuchtungstaste: Freezes the display reading or activates backlight.
- Probe Sockets (COM, VΩHz): Anschluss der Messleitungen für Voltage, Widerstand, Frequenz und andere Messwerte.
3.2. Anzeigefunktionen
- LCD-HD-Display: Liefert klare und leicht ablesbare Messwerte.
- Hintergrundbeleuchtungsfunktion: Verbessert die Sichtbarkeit bei schlechten Lichtverhältnissen.
- Larger Screen and Display Digits: Improves readability of measurement values.
4. Einrichtung
4.1. Einlegen der Batterie
The UNI-T UT202R requires 2 AA batteries (included). To install or replace batteries:
- Stellen Sie sicher, dass der Zähler ausgeschaltet ist.
- Suchen Sie die Batterieabdeckung auf der Rückseite des Geräts.
- Öffnen Sie die Batterieabdeckung mit einem Schraubendreher.
- Legen Sie die 2 AA-Batterien unter Beachtung der richtigen Polarität (+/-) ein.
- Schließen Sie die Batterieabdeckung sicher.
5. Bedienungsanleitung
This section details the various measurement functions of the UNI-T UT202R Digital Clamp Meter. Always select the appropriate function on the dial before making any measurements.
5.1. Wechselstrommessung
To measure AC current, rotate the function dial to the 'A~' position. Open the clamp jaw using the trigger and enclose a single conductor. The display will show the AC current reading. The meter supports selectable frequency for AC current measurements.
Video: Demonstration of AC current measurement using the clamp meter on an electrical panel, showing the current reading on the display. The video also highlights selectable frequency.
5.2. Wechselstrom-Voltage Messung
Zur Messung von AC-Voltage, rotate the function dial to the 'V~' position. Connect the red test lead to the VΩHz input jack and the black test lead to the COM input jack. Apply the test leads across the circuit points to measure AC voltage. The meter supports selectable frequency for AC voltage Messungen.
Video: Demonstration of AC voltage measurement using test leads on an electrical panel, showing the voltage reading on the display. The video also highlights selectable frequency.
5.3. DC-Voltage Messung
Zur Messung von DC-Voltage, rotate the function dial to the 'V=' position. Connect the red test lead to the VΩHz input jack and the black test lead to the COM input jack. Apply the test leads across the circuit points to measure DC voltage. This is demonstrated on a car battery and an electric bicycle battery.
Video: Demonstration of DC voltage measurement on a car battery and an electric bicycle battery, showing the voltage readings on the display.
5.4. Widerstandsmessung
To measure resistance, rotate the function dial to the 'Ω' position. Connect the test leads across the component to be measured. The display will show the resistance value in Ohms (Ω).
Video: Demonstration of resistance measurement on a circuit board, showing the resistance value on the display.
5.5. Diodenmessung
To test diodes, rotate the function dial to the 'Diode' symbol position. Connect the test leads across the diode. A healthy diode will show a voltagEin Spannungsabfall in der einen Richtung und ein offener Stromkreis (OL) in der entgegengesetzten Richtung.
Video: Demonstration of diode measurement on a circuit board, showing the voltage drop reading on the display.
5.6. Durchgangsprüfung
To perform a continuity test, rotate the function dial to the 'Continuity' symbol position. Connect the test leads across the circuit or component. The meter will emit an audible beep if continuity is detected (low resistance).
Video: Demonstration of a continuity test using test leads on a wire, showing the audible beep and display reading for continuity.
5.7. Kapazitätsmessung
To measure capacitance, rotate the function dial to the 'Capacitance' symbol position. Connect the test leads across the capacitor. The display will show the capacitance value. The UT202R supports capacitance measurement up to 4mF.
Video: Demonstration of capacitance measurement on a capacitor, showing the capacitance value on the display.
5.8. Temperaturmessung
To measure temperature, rotate the function dial to the 'Temperature' symbol position. Connect a K-type thermocouple (not included) to the meter. Place the thermocouple tip on the object or area to be measured. The display will show the temperature reading. The UT202R supports temperature measurement from -40°C to 1000°C.
Video: Demonstration of temperature measurement using a thermocouple on an air conditioning unit, showing the temperature reading on the display.
5.9. Frequenzmessung
To measure frequency, rotate the function dial to the 'Hz%' position. Connect the test leads to the circuit. The display will show the frequency value. The UT202R supports frequency measurement up to 10MHz.
Video: Demonstration of low voltage frequency measurement using a signal generator, showing the readings on the display.
5.10. Berührungsloses Volumentage (NCV) Messung
Zur Erkennung der Wechselstromspannungtage without contact, rotate the function dial to the 'NCV' position. Bring the NCV sensor near the conductor. The NCV warning lamp will illuminate, and the meter will beep, indicating the presence of AC voltage. The UT202R features 4-level NCV measurement for varying signal strengths.
Video: Demonstration of 4-level NCV measurement on electrical busbars, showing the NCV indicator and audible alerts.
5.11. Current Usage with Splitter (Optional Accessory)
For convenient measurement of home appliance current usage, the UT200+ series can be used with a splitter (e.g., UNI-T UT-LS15-US, sold separately). This accessory separates the live and ground wires, allowing the clamp meter to accurately measure the current of a plugged-in appliance.
Video: Demonstration of measuring current usage of a home appliance using the clamp meter with a UT-LS15-US splitter.
6. Spezifikationen
The following table outlines the key specifications for the UNI-T UT202R Digital Clamp Meter.

Image: Detailed specifications table for the UT200+ and UT200R series, including AC current, AC current frequency response, DC current, AC voltage, AC-Voltage frequency response, high voltage frequency, DC voltage, resistance, capacitance, temperature, frequency, display count, jaw opening, relative mode, zero mode, and category ratings.

Image: Table outlining features such as auto range, True RMS, continuity test, diode, low battery indication, data hold, Max/Min, and auto power off. Also includes characteristics like standard accessories, batteries, display, product size, product net weight, standard individual packing, standard quantity per carton, standard carton measurement, and standard carton gross weight.
| Parameter | Wert |
|---|---|
| Modellnummer | UT202R |
| Wechselstrom (A) | 400 A |
| Gleichstrom (A) | Nicht verfügbar |
| AC-Lautstärketage (V) | 600 V |
| DC-Voltage (V) | 600 V |
| Widerstand (Ω) | 40 MΩ |
| Kapazität (F) | 4 mF |
| Temperatur (°C) | -40°C bis 1000°C |
| Frequenz (Hz) | 10 Hz ~ 10 MHz |
| Anzahl anzeigen | 4000 |
| Kieferöffnung | 28 mm |
| Echter Effektivwert | Ja |
| Hintergrundbeleuchtung | Ja |
| Stromquelle | 2 AA-Batterien (im Lieferumfang enthalten) |
| Zertifizierungen | CE, UKCA, cETLus |
7. Wartung
To ensure the longevity and accuracy of your UNI-T UT202R Digital Clamp Meter, follow these maintenance guidelines:
- Reinigung: Reinigen Sie das Messgerät mit einem trockenen, weichen Tuch. Verwenden Sie keine Scheuermittel oder Lösungsmittel.
- Lagerung: Store the meter in a cool, dry place away from direct sunlight and extreme temperatures. Remove batteries if storing for extended periods.
- Kalibrierung: For professional applications, periodic calibration by qualified personnel is recommended to maintain accuracy.
- Messleitungen: Inspect test leads regularly for cuts, cracks, or damaged insulation. Replace immediately if any damage is found.
8. Fehlerbehebung
If you encounter issues with your UNI-T UT202R, refer to the following common troubleshooting steps:
- Keine Anzeige/Schwache Anzeige: Prüfen Sie den Batterieeinbau und tauschen Sie die Batterien gegebenenfalls aus. Stellen Sie sicher, dass das Messgerät eingeschaltet ist.
- Falsche Messwerte:
- Stellen Sie sicher, dass die richtige Messfunktion ausgewählt ist.
- Verify test lead connections are secure and undamaged.
- Check for proper contact with the circuit or component.
- Bei Strommessungen ist darauf zu achten, dass sich nur ein Leiter im Messbereich befindet.amp Kiefer.
- "OL" (Überlastung) Anzeige: Der Messwert liegt außerhalb des gewählten Bereichs. Wählen Sie einen höheren Messbereich oder stellen Sie sicher, dass die Messung innerhalb der Möglichkeiten des Messgeräts liegt.
- Kein Kontinuitätssignal: Check if the circuit is truly continuous or if the resistance is too high for the continuity threshold.
If problems persist, contact UNI-T customer support or a qualified technician.
9. Garantie und Support
For warranty information and technical support, please refer to the official UNI-T webBesuchen Sie unsere Website oder wenden Sie sich an Ihren Händler vor Ort. Bewahren Sie Ihren Kaufbeleg als Kaufnachweis für Garantieansprüche auf.