1. Einleitung
This manual provides essential information for the safe and efficient operation of your WZRELB 5000W 24V Pure Sine Wave Split Phase Power Inverter. Please read this manual thoroughly before installation and use. Retain this manual for future reference.
The WZRELB 5000W inverter converts 24 Volt DC battery power to 120V/240V AC split phase power, suitable for a wide range of applications including off-grid systems, RVs, and emergency backup power. It features a continuous output of 5000 watts and a peak surge capacity of 10000 watts, ensuring reliable power for demanding loads.
2. Sicherheitshinweise
WARNUNG: Die Nichtbeachtung dieser Anweisungen kann zu schweren Verletzungen oder Sachschäden führen.
- Sorgen Sie für eine ausreichende Belüftung rund um den Wechselrichter, um eine Überhitzung zu vermeiden.
- Setzen Sie den Wechselrichter keinem Wasser, Regen, Schnee oder Spritzwasser aus.
- Do not operate the inverter if it has received a sharp blow, been dropped, or otherwise damaged.
- Do not disassemble the inverter. Incorrect reassembly may result in electric shock or fire.
- Halten Sie Kinder vom Wechselrichter fern.
- Connect the inverter only to a 24V battery system. Connecting to a different voltage können Schäden verursachen.
- Schließen Sie das Erdungskabel immer ordnungsgemäß an.
- Ensure all connections are tight to prevent sparks and overheating.
3. Packungsinhalt
Überprüfen Sie, ob alle Artikel im Paket vorhanden sind:
- WZRELB 5000W Pure Sine Wave Inverter
- Batteriekabel (rot und schwarz)
- Ersatzsicherungen
- Drahtlose Fernbedienung
- Bedienungsanleitung

Image: The WZRELB 5000W Pure Sine Wave Inverter, showing the main unit, battery cables, and wireless remote control.
4. Produktüberschreitungview
Familiarize yourself with the components of your inverter.
4.1 Frontplatte (Wechselstromausgangsseite)

Bild: Vorderseite view of the WZRELB 5000W inverter, displaying the AC outlets, hardwire terminals, and power switch.
- AC-Steckdosen: Two dual 120V AC outlets, each supporting a maximum of 2500W.
- Hardwire Terminals:
- 1x 240VAC 3-wire terminal (L+N=240V) with 5000W max.
- 1x 4-wire terminal for Multi-mode (L1+L2=240V, L1+N=120V, L2+N=120V), supporting 120VAC and 240VAC output simultaneously.
- Stromschalter: ON/OFF switch for the inverter.
- Ground Wire Connector: Zur sicheren Erdung.

Bild: Detailliert view of the AC output panel, highlighting the 120V outlets, power switch, ground wire connector, and hardwire terminals for L1, N, L2, and G connections.

Image: Wiring diagram illustrating the split phase output, showing L1, N, L2, and G connections for both 120V and 240V outputs.
4.2 Rückseite (Gleichstromeingangsseite)

Bild: Rückseite view of the WZRELB 5000W inverter, showing the DC input terminals and cooling fans.
- Gleichstrom-Eingangsanschlüsse: Positive (Red) and Negative (Black) terminals for battery connection. Features spark-proof nuts.
- Kühlventilatoren: Temperature-controlled fans for efficient heat dissipation.

Bild: Detailliert view of the DC input panel, showing the positive and negative terminals with spark-proof nuts and the 90mm x 90mm cooling fans.
4.3 LCD Display

Image: The LCD display of the WZRELB inverter, showing various operational parameters such as battery status, temperature, and AC output voltage/aktuell.
- Status: Displays normal operation or fault codes.
- Batterie Voltage und Kapazität: Real-time battery status.
- Innentemperatur: Shows the inverter's operating temperature.
- Wechselstromausgang: Displays 120V and 240V output voltage und ampära.

Bild: Detailliert view of the LCD display with numbered labels indicating working status, temperature, battery voltage/capacity, AC1/AC2 voltage/ampere, and 240V output frequency.
4.4 drahtlose Fernbedienung

Image: The wireless remote control for the WZRELB inverter, featuring ON/OFF buttons and an antenna.
- Allows remote ON/OFF switching of the inverter.
- Effective range: up to 100ft indoors (with walls/doors) and 150ft in open areas.
- Requires a 23A 12V Alkaline Battery (not included).

Image: The inverter shown with its wireless remote control, illustrating the convenience of remote operation.
5. Einrichtung und Installation
Follow these steps carefully to connect your inverter to a 24V battery system.
5.1 Battery System Configuration
The inverter requires a 24V DC input. If using 12V batteries, connect them in series to achieve 24V.

Image: A visual guide for DC connection, showing the spark-proof nuts and the three steps for connecting battery cables.
- Batteriepole identifizieren: Confirm the positive (+) and negative (-) poles of your 12V batteries.
- Series Connection for 24V: Connect the positive terminal of one 12V battery to the negative terminal of another 12V battery using a short cable. This creates a 24V series connection.
- Anschluss an den Wechselrichter:
- Step 1: Connect Negative Cable First. Attach the black cable to the negative terminal of your 24V battery bank. Then, connect the other end of the black cable to the negative terminal of the inverter.
- Step 2: Contacting Spark-Proof Nut. After connecting the red cable to the positive terminal of your 24V battery bank, briefly touch the other side of the red cable to the spark-proof nut on the inverter's positive terminal for 3-5 seconds. This helps to prevent sparks during final connection.
- Step 3: Connect Positive Cable. Securely connect the red cable to the positive terminal of the inverter.
- Verbindungen festziehen: Ensure all screws on the battery terminals and inverter terminals are tightened to maintain stable current flow and prevent overheating.

Image: A three-step visual guide for connecting the DC cables to the inverter, emphasizing the spark-proof connection process.
Video: This video demonstrates the unboxing, overview of the inverter's panels, and the DC connection process for a WZRELB split phase inverter. It shows how to connect batteries and the inverter's terminals.
6. Bedienungsanleitung
6.1 Ein-/Ausschalten
- Manuelle Bedienung: Use the ON/OFF switch located on the AC output panel.
- Fernbedienung: Use the provided wireless remote control to switch the inverter ON or OFF from a distance.
6.2 Anschluss von Wechselstromgeräten
The inverter offers multiple AC output options:
- 120-V-Wechselstromsteckdosen: Plug your 120V appliances into the dual AC outlets. Each outlet supports up to 2500W.
- 240V AC Hardwire Terminal (3-wire): For 240V appliances, connect to the L+N=240V terminal. Maximum 5000W.
- Multi-mode Hardwire Terminal (4-wire): This terminal allows simultaneous 120V and 240V output. Connect L1+L2 for 240V, and L1+N or L2+N for 120V.
ACHTUNG: Überschreiten Sie nicht die maximale Wattzahltage for each outlet or terminal, and ensure the total load does not exceed the inverter's continuous power rating of 5000W.
7. Anwendungen
The WZRELB 5000W inverter is designed to power a variety of appliances, making it ideal for off-grid living, mobile businesses, RVs, trailers, semi-trucks, boats, and home backup during power outages.

Image: The inverter connected to various household appliances, demonstrating its capability to power multiple devices simultaneously.
Examples of compatible appliances include:
- Klimaanlagen
- Kühlschränke
- Elektrowerkzeuge
- Mikrowellen
- Kaffeemaschinen
- Beleuchtung
- Electronics (laptops, TVs, etc.)
Video: This video segment illustrates the WZRELB inverter powering various appliances such as a sandwich maker, electric pan, air fryer, and mini-fridge, showcasing its versatility in different power scenarios.
8. Schutz
The WZRELB inverter is equipped with multiple protection features to ensure safe and reliable operation:

Bild: Ein überview graphic highlighting the various protection features of the 5000W split phase inverter, including low voltage, Kurzschluss, Überspannungtage, electronic, overheat, charge, and reverse polarity protection.
- Soft Starter: Gradually increases output voltage to prevent damage to sensitive electronics and reduce inrush current.
- Überlastschutz: Schaltet sich automatisch ab, wenn die angeschlossene Last die Kapazität des Wechselrichters überschreitet.
- Kurzschlussschutz: Schützt vor Schäden durch Kurzschlüsse im Ausgang.
- Übertemperaturschutz: Aktiviert die Lüfter und schaltet sich ab, wenn die Innentemperatur zu hoch wird.
- Hohe Lautstärketage Herunterfahren: Protects the inverter and connected devices from excessive input voltage.
- Niedrige Lautstärketage Alarm/Abschaltung: Alerts and shuts down the inverter when battery voltage drops below a safe operating level, protecting your batteries.
- Internally Fused: Provides protection against internal electrical faults.
- Verpolungsschutz der Batterie: Verhindert Schäden bei versehentlich vertauschten Batterieanschlüssen.
Video: This video segment illustrates the inverter's soft start function and various protection mechanisms, including overload, low voltage, über voltage, and short circuit protection, as displayed on the LCD screen.
9. Wartung
Regelmäßige Wartung gewährleistet die Langlebigkeit und optimale Leistung Ihres Wechselrichters:
- Sauber halten: Periodically clean the exterior of the inverter, especially the cooling fan vents, to prevent dust buildup. Use a dry cloth.
- Verbindungen prüfen: Regularly inspect all DC and AC connections to ensure they are tight and free from corrosion. Loose connections can cause overheating and power loss.
- Belüftung: Ensure the inverter is always placed in a well-ventilated area, free from obstructions that could block airflow to the cooling fans.
- Batteriezustand: Monitor your battery bank's health and charge levels. A healthy battery system is crucial for inverter performance.
- Lagerung: Wenn Sie den Wechselrichter über einen längeren Zeitraum lagern, trennen Sie ihn von der Batterie und lagern Sie ihn an einem kühlen, trockenen Ort.
10. Fehlerbehebung
In diesem Abschnitt werden häufig auftretende Probleme behandelt, die bei Ihrem Wechselrichter auftreten können.
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| No AC output, inverter OFF | Niedrige Batterieladungtage, loose connections, inverter switch OFF, internal fuse blown. | Überprüfen Sie die Batterieladungtage and charge. Tighten all connections. Turn inverter ON. Check and replace fuses if necessary. |
| Inverter shuts down with alarm | Overload, over temperature, low/high battery voltage, Kurzschluss. | Reduce load. Ensure proper ventilation. Check battery voltage. Disconnect appliances and restart. |
| AC-Ausgangslautstärketage zu niedrig/hoch | Falsche Batterievoltage, heavy load, faulty wiring. | Ensure 24V battery input. Reduce load. Check wiring for proper gauge and connections. |
| Fernbedienung funktioniert nicht | Dead battery in remote, out of range, interference. | Replace remote battery (23A 12V). Move closer to inverter. Reduce potential interference sources. |
11. Spezifikationen
| Besonderheit | Detail |
|---|---|
| Modellnummer | SP5K24RC |
| Dauerhafte Leistung | 5000 Watt |
| Spitzenleistung (Überspannung) | 10000 Watt |
| DC-Eingangsvoltage | 24 Volt |
| AC-Ausgangsvolumentage | 120V / 240V Split Phase |
| Wellenform | Rein Sinus |
| Effizienz | Bis zu 91.6% |
| Technische Daten | 19.8 x 10 x 5.3 Zoll |
| Artikelgewicht | 25 Pfund |
| Empfohlene Batterietypen | AGM, Gel, Flooded, Lead-acid, Lithium-ion |
12. Garantie und Support