waveshare Modbus RTU Relay (D)

Waveshare Industrial Modbus RTU 8-Channel Relay Module (D) Instruction Manual

Model: Modbus RTU Relay (D)

1. Produktüberschreitungview

The Waveshare Industrial Modbus RTU 8-Channel Relay Module (D) is a robust and versatile device designed for industrial control and automation applications. It features 8 relay outputs and 8 digital inputs, communicating via the RS485 bus using the Modbus RTU protocol. This module incorporates multiple isolation protection circuits, including power isolation, magnetic isolation, and TVS diode protection, ensuring stable, reliable, and safe operation. Its rail-mounted ABS plastic enclosure facilitates easy installation in various industrial environments.

Waveshare Industrial Modbus RTU 8-Channel Relay Module (D)

Figure 1: Waveshare Industrial Modbus RTU 8-Channel Relay Module (D)

1.1. Produktvideo beendetview

Video 1: Modbus RTU Relay Series Overview. This video provides a general introduction to the Waveshare Modbus RTU relay series, highlighting key features and different versions available.

2. Packungsinhalt

Bitte überprüfen Sie, ob alle unten aufgeführten Artikel in Ihrem Paket enthalten sind:

  • Modbus RTU Relay (D) x1
  • Schraubendreher x1
Package Contents of Modbus RTU Relay (D)

Abbildung 2: Packungsinhalt

3. Funktionen und Spezifikationen

The Modbus RTU 8-Channel Relay Module (D) offers a comprehensive set of features for reliable industrial control:

  • Configurable device address (1~255), allowing multiple devices to be cascaded on the RS485 bus.
  • Features flash-on, flash-off function, enabling temporary relay activation with automatic closure.
  • Onboard unibody power supply isolation provides stable isolated voltage, eliminating the need for an extra power supply for the isolated terminal.
  • Onboard unibody magnetic isolation ensures signal isolation, high reliability, strong anti-interference, and low power consumption.
  • Onboard resettable fuse and TVS (Transient Voltage Suppressor) effectively suppress surge voltage und transiente Spike-Voltage, providing over-current/over-voltage protection, lightning protection, and anti-electrostatic capabilities.
  • Onboard Optocoupler isolation prevents interference from high-voltage Schaltungen.
  • Adopts a dedicated relay driver chip with built-in flyback diode protection for stronger and more stable driving ability.
  • Supports passive and active digital input with bi-directional optocoupler isolation and built-in debouncing algorithm. The relay supports digital input linkage control or toggle control.
  • Reverse-proof circuit prevents accidental damage from incorrect power connection.
  • High quality relay with contact rating: ≤10A 250VAC/30VDC.
  • Rail-mounted ABS plastic enclosure for easy installation and safe use.
  • Multiple LEDs for indicating MCU status and signal transceiving status.
RS485 8-Ch Relay Module (D) Overview

Figure 3: RS485 8-Channel Relay Module (D) with key features highlighted.

3.1. Technische Daten

ParameterWert
Stromversorgung7 bis 36 V
KommunikationsschnittstelleRS485
Baudrate4800, 9600, 19200, 38400, 57600, 115200, 128000, 256000
Standardkommunikationsformat9600, N, 8, 1
Relaiskanäle8
Kontaktformular1S 1Ö
Kontaktbewertung≤10A 250VAC/30VDC
Digitale Eingabe8DI, 5~36V, passive / active input (NPN or PNP), built-in bi-directional optocoupler isolation
KommunikationsprotokollStandard Modbus RTU-Protokoll
RS485-Adresse1-255
LED-AnzeigenSTA: MCU indicator, keeps flashing when the MCU normally working
TXD: TX indicator, lights up when sending data
RXD: RX indicator, lights up when receiving data
Technische Daten6.89 x 3.54 x 1.57 Zoll; 13.05 Unzen
Features At A Glance and Primary Function Diagram

Figure 4: Detailed specifications and primary function diagram.

4. Hardware-Overview und Schutz

The module is designed with multiple protection mechanisms to ensure safe and reliable operation:

  • Isolierung der Stromversorgung: Bietet stabile isolierte Volatilitättage, wodurch die Notwendigkeit einer externen Stromversorgung für den isolierten Anschluss entfällt.
  • Magnetic Coupling Isolation: Ensures signal isolation, high reliability, strong anti-interference, and low power consumption.
  • Optocoupler Isolation: Prevents interference from high-voltage Schaltungen.
  • TVS Lightning & ESD Protection: Unterdrückt effektiv Spannungsspitzentage und transiente Spike-Voltage.
  • Rückstellbare Sicherung: Provides over-current/over-voltage Schutz.
  • Dedicated Relay Driver Chip: With built-in flyback diode protection for stronger and more stable driving.
  • Reverse-Proof Circuit: Prevents accidental damage from incorrect power connection.
Hardware Analysis and Protection Circuits

Figure 5: Internal hardware components and protection circuits.

5. Digital Input Functionality

The module supports both passive (dry contact) and active (wet contact) digital inputs, with bi-directional optocoupler isolation and a built-in debouncing algorithm. This allows for flexible integration with various sensors and switches.

  • Passive Digital Input (Dry Contact): Connects to devices like button switches (self-reset) or ON/OFF switches (status hold).
  • Active Digital Input (Wet Contact): Connects to devices like NPN proximity sensors or IR curtain sensors.
Digital Input Connection Diagrams

Figure 6: Digital input types and connection diagrams.

6. Interfaces and Indicators

The module features multiple LED indicators to monitor its operating status and communication activity:

  • STA LED: MCU indicator, flashes when the MCU is operating normally.
  • TXD-LED: TX indicator, lights up when sending data.
  • RXD-LED: RX indicator, lights up when receiving data.
  • Relay Working Indicators: Individual LEDs for each relay channel indicate its current state (ON/OFF).
Schnittstellen und Indikatoren

Figure 7: Module interfaces and LED indicators.

7. Betriebsarten

The module supports multiple relay control modes for various automation scenarios, with each channel supporting independent control settings:

  • Normal Mode (Command Direct Control): Relays are controlled directly by sending Modbus commands.
  • Flash ON / Flash OFF: Allows turning the relay ON for a specified duration and then automatically turning it OFF (Flash ON), or turning it OFF for a duration and then automatically turning it ON (Flash OFF). The duration is set by passing an argument to the command.
  • Gestängesteuerung: The output status of a relay follows the digital input status, enabling direct control based on sensor readings or switch states.
  • Umschaltmodus: When a pulse is input, the output status of the relay will toggle once (ON to OFF, or OFF to ON).

8. RS485-Kommunikation

The module communicates via the RS485 interface using the Modbus RTU protocol. It supports configurable device addresses (1-255), allowing multiple modules to be cascaded on a single RS485 bus. For long communication distances or a large number of cascaded devices, RS485 repeaters may be necessary to maintain signal integrity and system efficiency.

RS485 Communication Diagram

Figure 8: RS485 communication setup with multiple cascaded devices.

9. Relay Connection

The onboard relays have a contact rating of ≤10A 250VAC/30VDC, allowing direct control of various devices. Ensure proper wiring according to the load type:

  • AC 220V Device Connection: Connect the AC load to the COM and NO (Normally Open) terminals of the relay.
  • DC 30V Device Connection: Connect the DC load to the COM and NO (Normally Open) terminals of the relay.

Always ensure the power supply to the module is within the 7~36V range.

10. Enclosure and Installation

The module is housed in a rail-mounted ABS plastic enclosure, designed for easy installation and secure mounting on standard DIN rails. This design simplifies integration into industrial control cabinets and systems, providing both convenience and safety.

11. Anwendungen

The Waveshare Modbus RTU Relay series products are suitable for a wide range of applications requiring intelligent and automated control:

  • Industrielle Steuerung: Valve control, pump station control, unattended industrial control systems.
  • Intelligentes Zuhause: Controlling appliances like air conditioners, access control, purifiers, water heaters, etc.
  • Intelligente Landwirtschaft: Controlling door curtain motors, air blowers, and other agricultural equipment.
  • Breeding & Farming: Controlling ventilators, lighting, water supply, feeding systems, etc.

12. Umrissmaße

The physical dimensions of the module are provided below for planning and integration purposes. All units are in millimeters (mm).

Outline Dimensions of the Module

Figure 9: Outline dimensions of the Modbus RTU Relay (D) module.

13. Fehlerbehebung

If you encounter issues with your Waveshare Industrial Modbus RTU 8-Channel Relay Module (D), please consider the following common troubleshooting steps:

  • Kein Strom/Anzeigen aus: Überprüfen Sie den Stromanschluss und stellen Sie sicher, dass die Spannungtage is within the 7~36V range. Verify the power adapter is functioning correctly.
  • Kommunikationsfehler: Ensure the RS485 A+, B-, and GND connections are correct and secure. Check the baudrate, parity, data bits, and stop bits settings on your Modbus master device match the module's default or configured settings. Verify the device address is unique and correctly set.
  • Relais schaltet nicht: Confirm that the Modbus commands sent are correct for the desired relay action (ON/OFF, Flash, Linkage, Toggle). Check the load connected to the relay is within the specified contact rating (≤10A 250VAC/30VDC).
  • Digital Input Not Responding: Ensure the digital input connections are correct for either passive (dry contact) or active (wet contact) input. Verify the external switch or sensor is functioning properly.
  • Intermittierender Betrieb: Check for loose connections or environmental interference. Ensure proper grounding.

For persistent issues, refer to the detailed product documentation available on the Waveshare website or contact Waveshare technical support.

14. Garantie und Support

Waveshare products typically come with a standard manufacturer's warranty. For specific warranty terms and conditions, please refer to the warranty information provided with your purchase or visit the official Waveshare website. Technical support is available through the Waveshare support channels, including online documentation, forums, and direct contact options. Please have your product model and purchase details ready when seeking support.

For the latest drivers, software, and detailed technical resources, please visit the Waveshare official webWebsite: www.waveshare.com

Zugehörige Dokumente - Modbus RTU Relay (D)

Vorview Waveshare Modbus RTU Analogeingang 8-Kanal – Benutzerhandbuch und technische Spezifikation
Ausführlicher Leitfaden zum Waveshare Modbus RTU Analog Input 8CH Modul, der Hardwarebeschreibung, Versionsvergleich, Konfiguration, Softwaretests mit SSCOM und Modbus Poll sowie Entwicklungsprotokolle für Raspberry Pi, STM32 und Arduino umfasst.
Vorview Modbus RTU Relay: Benutzerhandbuch und Technischer Leitfaden
Ausführlicher Leitfaden zum Modbus RTU Relay mit Sicherheitshinweisen, Hardwareanschluss, Softwareeinrichtung mit SSCOM und Modbus Poll sowie detaillierten Befehlsprotokollen für verschiedene Operationen. Enthält Beispiele.amples für Raspberry Pi, STM32, Arduino und SPS-Integration.
Vorview Analoges Modbus-RTU-8-Kanal-Eingangsmodul von Waveshare
Dieses Dokument stellt das 8-Kanal-analoge Modbus-RTU-Eingangsmodul von Waveshare vor, das sich mit der Erfassung von Spannungsdaten und dem Betrieb in industriellen Automatisierungssystemen befasst. Im Detail werden die technischen Daten, die Verbindungsmethoden, die Logiktests und das Modbus-Kommunikationsprotokoll beschrieben.
Vorview Modbus RTU Relay 32CH – Benutzerhandbuch und Technischer Leitfaden
Umfassendes Benutzerhandbuch und technischer Leitfaden für das Modbus RTU Relay 32CH. Behandelt Sicherheit, Hardware, Softwareintegration (Raspberry Pi, STM32, Arduino, SPS) und Modbus RTU-Befehlsprotokolle für die industrielle Automatisierung.
Vorview Modbus RTU E/S 8CH: Industrial 8-Channel Digital Input/Output Module
Comprehensive technical guide for the Waveshare Modbus RTU E/S 8CH module, detailing its specifications, wiring, primary functions, testing procedures, and Modbus communication protocol for industrial automation applications.
Vorview Waveshare Modbus POE ETH Relay 30CH: User Manual and Configuration Guide
This document provides a comprehensive guide to the Waveshare Modbus POE ETH Relay 30CH. It covers product overview, hardware connection, electrical safety precautions, detailed specifications, indicator descriptions, configuration methods using VirCom software and web interface, protocol settings (Modbus RTU/TCP), virtual serial port setup, software demonstrations with SSCOM and Modbus Poll, Raspberry Pi integration, and Modbus development protocols. Learn how to control and monitor industrial automation devices.