ELKO EL-430

ELKO EL-430 Clock/Desk Type Aneroid Blood Pressure Sphygmomanometer

Bedienungsanleitung

Einführung

This manual provides detailed instructions for the proper use, setup, and maintenance of your ELKO EL-430 Clock/Desk Type Aneroid Blood Pressure Sphygmomanometer. Please read this manual thoroughly before using the device to ensure accurate readings and safe operation. This device is designed for professional and home use to measure blood pressure non-invasively.

Lieferumfang

ELKO EL-430 Sphygmomanometer components and packaging

Image showing the ELKO EL-430 Sphygmomanometer packaging and its main components: the high precision gauge, BP bulb with valve, and special design cotton cuff.

Upon opening the package, verify that all components are present and undamaged. The standard package for the ELKO EL-430 includes:

Hauptmerkmale

ELKO EL-430 Clock/Desk Type Aneroid Blood Pressure Sphygmomanometer

Image of the ELKO EL-430 Clock/Desk Type Aneroid Blood Pressure Sphygmomanometer, showing the large clock-face gauge, the black cotton cuff, and the inflation bulb.

Aufstellen

Before taking a measurement, ensure the device is properly assembled and positioned. The EL-430 is a clock/desk type unit, designed for stable placement during use.

  1. Komponenten auspacken: Carefully remove the sphygmomanometer, cuff, and inflation bulb from the packaging.
  2. Connect Cuff and Bulb: Ensure the cuff and inflation bulb are securely connected to the gauge via their respective tubes. The dual-tube bladder should be correctly attached.
  3. Positionieren Sie das Gerät: Place the main gauge unit on a stable, flat surface, such as a desk or table, at approximately heart level. The integrated basket can be used to keep the cuff and bulb organized.
  4. Patientenvorbereitung: The patient should be seated comfortably with their arm resting on a flat surface, palm facing upwards. Ensure the arm is relaxed and at heart level. Avoid talking or moving during the measurement.

Operating Instructions: Measurement Procedures

Blood Pressure Measurement Procedures

Image illustrating the four key steps for blood pressure measurement: stethoscope placement, cuff inflation, listening for Korotkoff sounds, and controlled deflation.

Befolgen Sie diese Schritte für eine genaue Blutdruckmessung:

  1. Cuff Placement and Stethoscope Positioning: Wrap the cuff firmly around the upper arm, ensuring it is snug but not too tight. The lower edge of the cuff should be about 1 inch (2-3 cm) above the elbow joint. Place the stethoscope head over the main artery (brachial artery), which is typically found on the inner side of the arm, underneath the artery mark of the cuff.
  2. Inflation: With the air release valve completely closed, press the inflation bulb repeatedly and continue pumping until the gauge reads a value 20-30 mmHg above your normal systolic blood pressure. If you do not know your normal systolic pressure, inflate to approximately 180-200 mmHg.
  3. Listening and Recording Systolic Pressure: Slowly open the air release valve to deflate the cuff at a rate of 2-3 mmHg per second. Listen carefully through the stethoscope. The first distinct, rhythmic sound you hear (Korotkoff sound) indicates the systolic pressure (the upper number). Note the reading on the gauge at this exact moment.
  4. Listening and Recording Diastolic Pressure: Continue to slowly deflate the cuff. The point at which the Korotkoff sounds completely disappear indicates the diastolischer Druck (the lower number). Note this reading on the gauge. If the sounds become muffled but do not disappear, the muffled sound point can be considered the diastolic pressure.

Blutdruckwerte verstehen

Blood Pressure Chart and Reading Precautions

Image displaying a blood pressure chart categorizing readings (Normal, Elevated, High Blood Pressure Stages 1 & 2, Hypertensive Crisis) and a list of conditions under which a reading should not be attempted.

Refer to the chart below for general blood pressure categories. Consult a healthcare professional for interpretation of your readings and personalized advice.

Blood Pressure Chart (mmHg)
Blutdruck KategorieSystolic (upper number)Diastolic (lower number)
NormalWeniger als 120Weniger als 80
Erhöht120 - 129Weniger als 80
Bluthochdruck (Hypertonie) Stage 1130 - 13980 - 89
Bluthochdruck (Hypertonie) Stage 2140 oder höher90 oder höher
Hypertensive Crisis (consult your doctor immediately)Höher als 180Höher als 120

DO NOT ATTEMPT A READING...

  1. Within 1 hour of food intake.
  2. Immediately after a tea, coffee, or a smoke.
  3. Within 20 minutes of taking a bath.
  4. While talking or moving your hand/fingers.
  5. When climate is very cold.
  6. When bladder is full or you feel like discharging urine.

Wartung und Pflege

Proper maintenance ensures the longevity and accuracy of your sphygmomanometer.

Fehlerbehebung

If you encounter issues with your ELKO EL-430, refer to the following common problems and solutions:

Technische Daten

SpezifikationDetail
ModellnummerEL-430
AnzeigetypAnalog
Messbereich0 - 300 mmHg
Genauigkeit+/- 3 mmHg
ManschettentypLarge Cotton Cuff with Velcro Fasteners
Im Lieferumfang enthaltene KomponentenCuff, Gauge, Inflation Bulb with Valve
Artikelgewicht600 g
Produktabmessungen (L x B x H)14L x 14W x 18Th Centimeters
HerstellerAnita Industries
UrsprungslandIndien
Datum der ersten Verfügbarkeit12. Februar 2024

Garantie und Support

For warranty information, technical support, or service inquiries regarding your ELKO EL-430 Sphygmomanometer, please contact the manufacturer directly.

Kontaktdaten des Herstellers:
Anita Industries
New Delhi, India
E-Mail: info@elkoindia.com
Telefon: +91 9911129201

Please have your model number (EL-430) and date of purchase available when contacting support.

Zugehörige Dokumente - EL-430

Vorview ELKO RS16 TV/SAT/R-Steckdose: Hinweise zum Ende der Lebensdauer und zur Entsorgung
Ausführlicher Leitfaden für die Entsorgung und Behandlung der ELKO RS16 TV/SAT/R-Buchse am Ende ihrer Lebensdauer, einschließlich Produktdetails, Komponenteninformationen und Recyclingpotenzial gemäß WEEE-Richtlinie.
Vorview ELKO Smart Heizkörperthermostat – Benutzerhandbuch
Ausführliche Bedienungsanleitung für den ELKO Smart-Heizkörperthermostat mit Informationen zu Inbetriebnahme, Einrichtung, Konfiguration, Nutzung, Fehlerbehebung und technischen Daten. Erfahren Sie, wie Sie Ihr Heizsystem koppeln, steuern und automatisieren, um Komfort und Energieeffizienz zu optimieren.
Vorview ELKO Schuko-Steckdose mit USB 3.0 A-Ladegerät – Installations- und Bedienungsanleitung
Ausführlicher Leitfaden für die ELKO Schuko-Steckdose mit zwei USB 3.0 A-Ladeanschlüssen (Typ A und Typ C). Enthält wichtige Sicherheitshinweise, detaillierte technische Daten, Installationsanleitungen und Gebrauchshinweise für Elektrofachkräfte und Endverbraucher.
Vorview ELKO Plus / ELKO RS16 DCL Wandsteckdose Installationsanleitung
Ausführliche Installationsanleitung für ELKO Plus und ELKO RS16 DCL Wandsteckdosen. Enthält wichtige Sicherheitshinweise, schrittweise Montageanleitungen, Hinweise zum Abnehmen der Abdeckung, zum Steckeranschluss, technische Daten und Informationen zur sachgemäßen Entsorgung. Unverzichtbar für qualifizierte Elektriker.
Vorview ELKO Smart Heizkörperthermostat – Benutzerhandbuch – Installation, Konfiguration und Betrieb
Ausführliche Bedienungsanleitung für den ELKO Smart Heizkörperthermostat (EKO09765), die Installation, Kopplung, Konfiguration, tägliche Nutzung, Zeitplanung, Automatisierung, Fehlerbehebung und technische Spezifikationen abdeckt.
Vorview ELKO Smart Heizkörperthermostat Brukerhåndbok
Detaljert brukerhåndbok for ELKO Smart Radiatorthermostat, som eccre opsett, bruk, paring, automasjon, feilsøking and tekniske spesifikasjoner for optimal hemmeopparming.