Elitech LMG-10

Elitech LMG-10 Digitales Manometer-System – Benutzerhandbuch

Modell: LMG-10, LMC-100A+, ILD-200

Marke: Elitech

1. Einleitung

This user manual provides comprehensive instructions for the Elitech LMG-10 Digital Manifold Gauge, LMC-100A+ Refrigerant Scale, and ILD-200 Infrared Leak Detector. This integrated system is designed for HVAC professionals to accurately measure pressure, temperature, refrigerant weight, and detect refrigerant leaks in HVAC/R systems. Please read this manual thoroughly before operation to ensure proper use and safety.

Elitech LMG-10 Digital Manifold Gauge System with Scale and Leak Detector

Figure 1: Complete Elitech LMG-10 Digital Manifold Gauge System including the manifold, refrigerant scale, leak detector, and hoses.

2. Sicherheitshinweise

Beachten Sie stets die folgenden Sicherheitsvorkehrungen, um Verletzungen oder Schäden am Gerät zu vermeiden:

  • Beim Umgang mit Kältemitteln ist geeignete persönliche Schutzausrüstung (PSA), einschließlich Schutzbrille und Handschuhen, zu tragen.
  • Beim Umgang mit Kältemitteln ist für ausreichende Belüftung zu sorgen.
  • Do not expose the devices to extreme temperatures, humidity, or corrosive environments.
  • Do not attempt to disassemble or modify the equipment. Refer all servicing to qualified personnel.
  • Verify that all connections are secure before applying pressure or vacuum.
  • Verwenden Sie ausschließlich die angegebenen Stromquellen und Zubehörteile.
  • Keep the equipment away from children and unauthorized personnel.

3. Packungsinhalt

Überprüfen Sie, ob alle Artikel im Paket vorhanden sind:

  • Elitech LMG-10 Digital Manifold Gauge
  • Elitech LMC-100A+ Refrigerant Scale
  • Elitech ILD-200 Infrared Leak Detector
  • Charging Hoses (Red, Yellow, Blue)
  • Temperatur Clampm (2)
  • Benutzerhandbuch (dieses Dokument)
  • Carrying Case (for LMG-10 and accessories)
Elitech LMG-10 Digital Manifold Gauge with carrying case and temperature clamps

Figure 2: Elitech LMG-10 Digital Manifold Gauge, temperature clamps, and protective carrying case.

4. Produktüberschreitungview

4.1 Elitech LMG-10 Digital Manifold Gauge

The LMG-10 is a robust digital manifold gauge designed for precise pressure and temperature measurements in HVAC/R systems. It supports 88 types of refrigerants and automatically calculates superheat and subcooling.

  • Anzeige: Large LCD for clear readings.
  • Kältemittelunterstützung: Pre-programmed with 88 common refrigerants.
  • Einheit: Supports psi, kg/cm², kPa, MPa, bar for pressure; °F/°C for temperature.
  • Merkmale: Temperature compensation, auto-off function.
Elitech LMG-10 Digital Manifold Gauge displaying features like temperature compensation, 88 refrigerants, superheating & subcooling, large display, compact, and 200h battery life.

Figure 3: Key features of the Elitech LMG-10 Digital Manifold Gauge, highlighting its capabilities.

4.2 Elitech LMC-100A+ Refrigerant Scale

The LMC-100A+ is a high-capacity refrigerant charging scale, essential for accurate refrigerant charging and recovery. It offers high precision and multiple unit options.

  • Kapazität: Bis zu 100 kg (220 lbs).
  • Genauigkeit: ±0.05% readings +10g.
  • Einheit: Kg, Lb, Oz.
  • Merkmale: Long battery life (up to 40 hours), auto shut-off after 10 minutes of inactivity.
Elitech LMC-100A+ Refrigerant Scale showing long battery life and auto shut-off feature.

Figure 4: The Elitech LMC-100A+ Refrigerant Scale, emphasizing its extended battery life and automatic power-saving function.

Elitech LMC-100A+ Refrigerant Scale in use, displaying a reading of 5.00 kg.

Figure 5: The Elitech LMC-100A+ Refrigerant Scale actively measuring refrigerant weight, showing a clear digital display.

4.3 Elitech ILD-200 Infrared Leak Detector

The ILD-200 is an advanced infrared refrigerant leak detector offering superior sensitivity and faster response times compared to traditional heated diode detectors.

  • Nachweismethode: Infrared sensor technology.
  • Empfindlichkeit: Max 0.1 oz/yr.
  • Ansprechzeit: Immediate.
  • Normen: Meets EN14624, SAE-162, SAE-2791, and SAE-2913 standards.
  • Anzeige: 2.8" large screen with peak display.
Elitech ILD-200 Infrared Leak Detector with dimensions and specifications.

Figure 6: Elitech ILD-200 Infrared Leak Detector, detailing its physical dimensions and key technical specifications.

Elitech ILD-200 Infrared Leak Detector's 2.8 inch large screen displaying sensitivity and peak detection.

Figure 7: Close-up of the Elitech ILD-200's large display, showing its sensitivity indicator and peak leak detection feature.

4.4 Charging Hoses

The included charging hoses are designed for high-pressure refrigerant applications, ensuring safe and efficient transfer.

  • Arbeitsdruck: 800 PSI.
  • Berstdruck: 4000 PSI.
  • Farben: Red, Yellow, Blue for easy identification of high-side, low-side, and service ports.
Red, yellow, and blue charging hoses with working and burst pressure ratings.

Figure 8: The set of red, yellow, and blue charging hoses, indicating their working and burst pressure capabilities.

5. Einrichtung

5.1 Initial Setup of LMG-10 Digital Manifold Gauge

  1. Einlegen der Batterie: Open the battery compartment on the back of the LMG-10 and insert the required batteries (refer to specifications for type).
  2. Einschalten: Drücken Sie die Einschalttaste, um das Gerät einzuschalten.
  3. Einheitenauswahl: Use the "MODE" button to cycle through pressure and temperature units. Use the arrow buttons to select desired units (e.g., psi, °F).
  4. Kältemittelauswahl: Press the refrigerant selection button (if available, or cycle through modes) to choose the appropriate refrigerant type for your system.
  5. Zeroing Pressure: With all hoses disconnected and valves closed, press the "ZERO" button to zero the pressure readings.

5.2 Initial Setup of LMC-100A+ Refrigerant Scale

  1. Einlegen der Batterie: Install batteries into the scale's remote display unit.
  2. Platzierung: Stellen Sie die Waage auf eine ebene, stabile Oberfläche.
  3. Einschalten: Press the "POWER" button on the remote display.
  4. Einheitenauswahl: Press the "UNIT" button to select the desired weight unit (Kg, Lb, or Oz).
  5. Zeroing Scale: Ensure nothing is on the scale platform, then press the "Z/T" (Zero/Tare) button to zero the reading.

5.3 Initial Setup of ILD-200 Infrared Leak Detector

  1. Einlegen der Batterie: Open the battery compartment and insert the specified battery (e.g., 3.7V 3000mAh).
  2. Einschalten: Press and hold the power button until the device turns on. Allow a brief warm-up period.
  3. Empfindlichkeitseinstellung: Use the "SENS" button to cycle through sensitivity levels (e.g., H for High, M for Medium, L for Low) based on the expected leak size.

6. Bedienungsanleitung

6.1 Using the LMG-10 Digital Manifold Gauge

  1. Schläuche anschließen:
    • Connect the blue hose to the low-side service port of the HVAC system and the blue port on the LMG-10.
    • Connect the red hose to the high-side service port of the HVAC system and the red port on the LMG-10.
    • Connect the yellow (service) hose to the center port of the LMG-10. This hose will be used for vacuum pump or refrigerant tank connections.
  2. Attach Temperature Clamps: Securely attach the temperature clamps to the suction line (low-side) and liquid line (high-side) of the system to measure pipe temperatures for superheat/subcooling calculations.
  3. Lesungen: Once connected, the LMG-10 will display real-time pressure and temperature readings. Superheat and subcooling values will be calculated automatically based on the selected refrigerant.
  4. Staubsaugen:
    • Connect the yellow hose to a vacuum pump.
    • Open both high and low-side valves on the LMG-10.
    • Start the vacuum pump and monitor the vacuum reading on the LMG-10.
    • Once the desired vacuum level is reached, close both valves on the LMG-10 and turn off the vacuum pump.
  5. Laden/Wiederherstellung:
    • Connect the yellow hose to the refrigerant tank (for charging) or recovery machine (for recovery).
    • Use the LMC-100A+ scale to monitor the refrigerant weight.
    • Open the appropriate valve(s) on the LMG-10 to allow refrigerant flow.
    • Monitor pressure and temperature readings during the process.

6.2 Using the LMC-100A+ Refrigerant Scale

  1. Platzieren Sie den Panzer: Place the refrigerant tank securely on the center of the scale platform.
  2. Eigengewicht: Press the "Z/T" button to tare the weight of the tank, setting the display to zero. This allows you to measure only the amount of refrigerant added or removed.
  3. Gewicht des Monitors: As refrigerant is charged or recovered, the display will show the net change in weight.
  4. Hold-Funktion: Some models may have a "HOLD" button to freeze the current reading.

6.3 Using the ILD-200 Infrared Leak Detector

  1. Einschalten und Aufwärmen: Turn on the ILD-200 and allow it to warm up as indicated by the device (usually a few seconds).
  2. Empfindlichkeit auswählen: Choose the appropriate sensitivity (H, M, L) based on the suspected leak size and environment. Start with high sensitivity for general scanning.
  3. Scanbereich: Slowly move the probe tip around suspected leak points (e.g., fittings, valves, coils) at a rate of approximately 1-2 inches per second.
  4. Detecting Leaks: When a leak is detected, the device will emit an audible alarm and/or visual indication (e.g., LED bar graph, display reading). The alarm frequency or intensity typically increases with the concentration of refrigerant.
  5. Lecks aufspüren: Once a leak is indicated, move the probe away and then slowly approach the area again to pinpoint the exact source. Reduce sensitivity if the alarm is constant and overwhelming.
  6. Reset-Funktion: Use the "RESET" button to clear the current reading and re-zero the sensor in a clean air environment.
  7. Mute-Funktion: Use the "MUTE" button to silence the audible alarm if desired.

7. Wartung

7.1 Allgemeine Pflege

  • Keep all components clean and free from dirt, dust, and moisture.
  • Wischen Sie Oberflächen mit einem weichen, damp Tuch. Keine Scheuer- oder Lösungsmittel verwenden.
  • Store the equipment in its protective carrying case when not in use.

7.2 Batteriewechsel

  • LMG-10: Replace batteries when the low battery indicator appears on the display. Refer to the battery compartment for specific battery type (e.g., AA, AAA).
  • LMC-100A+: Replace batteries in the remote display unit when the battery indicator is low.
  • ILD-200: Replace the internal rechargeable battery or standard batteries as needed. Ensure proper polarity.

7.3 Sensor Maintenance (ILD-200)

The infrared sensor in the ILD-200 is generally maintenance-free. However, avoid exposing the sensor tip to excessive dirt or oil. If performance degrades, contact Elitech support.

8. Fehlerbehebung

ProblemMögliche UrsacheLösung
LMG-10 does not power on.Defekte oder falsch eingesetzte Batterien.Batteriepolarität prüfen; Batterien austauschen.
Inaccurate pressure readings on LMG-10.Gauge not zeroed; sensor contamination; faulty connection.Zero the gauge before use; ensure clean connections; check for leaks in hoses.
LMC-100A+ scale shows "Err" or unstable readings.Uneven surface; overloaded; battery low; interference.Place on a flat, stable surface; ensure weight is within capacity; replace batteries; move away from strong electromagnetic fields.
ILD-200 constantly alarms or gives false positives.High background refrigerant concentration; sensor contaminated; sensitivity too high.Move to a clean air environment and reset; clean probe tip; reduce sensitivity.
ILD-200 does not detect leaks.Low sensitivity; sensor failure; battery low.Increase sensitivity; replace battery; contact support if sensor is suspected faulty.

9. Spezifikationen

KomponenteSpezifikationWert
LMG-10 Digital Manifold GaugeUnterstützte Kältemittel88 Typen
Druckeinheitenpsi, kg/cm², kPa, MPa, bar
Temperatureinheiten°F/°C
AkkulaufzeitBis zu 200 Stunden
MerkmaleSuperheat/Subcooling auto-calc, Temp Compensation, Auto-off
LMC-100A+ Refrigerant ScaleKapazität220 kg
Genauigkeit±0.05% readings +10g
Gewichtseinheitenkg, lb, Oz
AkkulaufzeitBis zu 40 Stunden
ILD-200 Infrared Leak DetectorMaximale Empfindlichkeit0.1 oz/Jahr
AnsprechzeitSofort
Batterie3.7 V, 3000 mAh
Standards erfülltEN14624, SAE-162, SAE-2791, SAE-2913
Anzeige2.8" Large Screen Peak Display
LadeschläucheArbeitsdruck800 PSI
Berstdruck4000 PSI
Allgemeine ProduktabmessungenTechnische Daten11 x 8 x 14 Zoll
Artikelgewicht1.1 Pfund
MaterialNylon, Polypropylene, Rubber

10. Garantie und Support

Elitech provides dedicated customer service and technical support for its products. For any inquiries, technical assistance, or warranty claims, please contact Elitech's local team.

  • Kundendienst: Rund um die Uhr verfügbar.
  • Technische Unterstützung: Available for product operation and troubleshooting.
  • Garantieinformationen: Refer to the product packaging or Elitech's official webAuf der Webseite finden Sie die detaillierten Garantiebedingungen.
  • Kontaktinformationen: Besuchen Sie die offizielle Elitech-Website. website or refer to the contact details provided with your product for the most up-to-date support channels.

Zugehörige Dokumente - LMG-10

Vorview Benutzerhandbuch für den Infrarot-Kältemittellecksucher der ILD-Serie von Elitech
Ausführliches Benutzerhandbuch für die Elitech ILD-Serie Infrarot-Kältemittellecksuchgeräte (ILD-100, ILD-200, ILD-300) mit Spezifikationen, Bedienung, Wartung und Funktionen. Erfahren Sie, wie Sie mit diesem fortschrittlichen Gerät Kältemittellecks effektiv aufspüren.
Vorview Elitech ILD-100/ILD-200/ILD-300 Infrarot-Lecksuchgerät – Benutzerhandbuch
Benutzerhandbuch für die Elitech ILD-Serie Infrarot-Kältemittellecksuchgeräte (ILD-100, ILD-200, ILD-300). Enthält detaillierte Informationen zu Betrieb, Spezifikationen, Funktionen und Wartung für die präzise Erkennung von Kältemittellecks.
Vorview Elitech IR-200 Infrarot- und Heizdioden-Lecksucher Benutzerhandbuch
Ausführliches Benutzerhandbuch für den Elitech IR-200, einen Doppelsensor-Lecksucher mit Infrarot- und Heizdiodentechnologie. Erfahren Sie mehr über Spezifikationen, Bedienung, Wartung und Funktionen zur Erkennung von Kältemittellecks.
Vorview Elitech MS-100 PLUS Smart Digital Manometer – Benutzerhandbuch
Ausführliches Benutzerhandbuch für das Elitech MS-100 PLUS Smart Digital Manometer, einschließlich Produkteinführung, Sicherheitshinweise und mehr.view, Tastenfunktionen, technische Parameter und Kurzanleitungen für Kälte- und Klimatechniksysteme.