ProLine 116-502

ProLine 116-502 Gas Ball Valve

Bedienungsanleitung

1. Produktüberschreitungview

The ProLine 116-502 Gas Ball Valve is a forged brass valve designed for reliable shut-off in natural gas or LP gas applications. It features a durable 1-piece body construction and convenient 3/8-inch flare x flare connections. The valve is equipped with a chrome-plated ball and a quarter-turn lever handle for easy operation. This product is CSA 3-88 certified, ensuring compliance with safety and performance standards for gas appliances.

ProLine 116-502 Gas Ball Valve with yellow lever handle and flare connections.

This image displays the ProLine 116-502 Gas Ball Valve, featuring a brass body, a yellow quarter-turn lever handle, and 3/8-inch flare connections on both ends. The valve is designed for gas applications.

2. Sicherheitshinweise

WARNUNG: Unsachgemäße Installation, Einstellung, Änderung, Service oder Wartung kann zu Sachschäden, Verletzungen oder Tod führen. Lesen Sie die Installations-, Betriebs- und Wartungsanweisungen sorgfältig durch, bevor Sie dieses Gerät installieren oder warten.

  • Vor Installationen oder Wartungsarbeiten muss stets die Gaszufuhr abgestellt sein.
  • Die Installation muss von einem qualifizierten Fachmann unter Einhaltung aller örtlichen Vorschriften und Bestimmungen durchgeführt werden.
  • Verwenden Sie geeignete Werkzeuge und persönliche Schutzausrüstung.
  • Check for leaks after installation using a non-corrosive leak detection solution.
  • Verwenden Sie keine offenen Flammen, um nach Gaslecks zu suchen.
  • This valve is intended for natural gas or LP gas applications only. Do not use for other media.

3. Einrichtung und Installation

This section provides general guidelines for the installation of the ProLine 116-502 Gas Ball Valve. Always refer to local plumbing and gas codes for specific requirements.

3.1 Prüfungen vor der Installation

  1. Verify that the valve model 116-502 is suitable for your specific gas application (natural gas or LP gas).
  2. Ensure the connection sizes (3/8-inch flare) match your existing piping.
  3. Inspect the valve for any visible damage before installation. Do not install a damaged valve.
  4. Gather all necessary tools, including wrenches, pipe thread sealant (if applicable for other connections in the system), and leak detection solution.

3.2 Installationsschritte

  1. Turn off Gas Supply: Locate the main gas shut-off valve and turn off the gas supply to the area where the valve will be installed.
  2. Verbindungen vorbereiten: Ensure the flare connections on your gas lines are clean and free of debris.
  3. Anschlussventil: Align the valve with the gas lines. Hand-tighten the flare nuts onto the valve's flare connections.
  4. Verbindungen festziehen: Using appropriate wrenches, carefully tighten the flare nuts. Do not overtighten, as this can damage the flare connections. Refer to manufacturer's recommendations for torque specifications if available, or tighten until snug and then an additional quarter to half turn.
  5. Gasversorgung wiederherstellen: Slowly turn the main gas supply back on.
  6. Auf Lecks prüfen: Apply a non-corrosive leak detection solution to all new connections. Bubbles indicate a leak. If a leak is detected, turn off the gas supply immediately, re-tighten the connection, and re-test. Repeat until no leaks are present.

4. Bedienungsanleitung

The ProLine 116-502 Gas Ball Valve is designed for simple on/off operation.

  • Zum Öffnen des Ventils: Rotate the yellow lever handle 90 degrees (a quarter-turn) so that it is parallel with the gas flow direction.
  • Zum Schließen des Ventils: Rotate the yellow lever handle 90 degrees (a quarter-turn) so that it is perpendicular to the gas flow direction.

The quarter-turn design allows for quick and easy visual confirmation of the valve's open or closed status.

5. Wartung

The ProLine 116-502 Gas Ball Valve is designed for long-term, maintenance-free operation under normal conditions. Regular inspection is recommended.

  • Regelmäßige Inspektion: Visually inspect the valve and connections periodically for any signs of corrosion, damage, or leaks.
  • Dichtigkeitsprüfungen: If you suspect a leak, perform a leak check using a non-corrosive leak detection solution.
  • Reinigung: Clean the exterior of the valve with a damp Bei Bedarf mit einem Tuch abwischen. Keine scharfen Chemikalien oder Scheuermittel verwenden.
  • Keine vom Benutzer zu wartenden Teile: This valve contains no user-serviceable parts. Do not attempt to disassemble or repair the valve. If the valve is damaged or malfunctioning, it must be replaced by a qualified professional.

6. Fehlerbehebung

This section addresses common issues that may arise with gas ball valves. Always prioritize safety and consult a professional for any complex issues.

  • Gas Leak Detected:
    • Symptom: Smell of gas, or bubbles when leak detection solution is applied.
    • Aktion: Immediately turn off the main gas supply. Re-check all connections for proper tightening. If the leak persists, do not attempt further repairs. Contact a qualified gas technician.
  • Valve Difficult to Turn:
    • Symptom: Lever handle is stiff or hard to rotate.
    • Aktion: Do not force the handle. Excessive force can damage the valve. If the valve is new, it may be slightly stiff initially. If it becomes stiff over time, it may indicate internal wear or debris. The valve should be replaced by a qualified professional.
  • Kein Gasfluss:
    • Symptom: Appliance not receiving gas, even with valve in open position.
    • Aktion: Ensure the valve handle is fully parallel to the pipe (open position). Check other shut-off valves in the system and the main gas supply. If the issue persists, contact a qualified gas technician.

7. Spezifikationen

SpezifikationDetail
Modellnummer116-502
MarkeProLine
MaterialForged Brass (Chrome Plated Ball)
VerbindungstypFlare x Flare
Anschlussgröße3/8 Zoll x 3/8 Zoll
BetriebQuarter-Turn Lever Handle
ZertifizierungenCSA 3-88
AnwendungErdgas oder Flüssiggas
Artikelgewicht3.7 Pfund (für die 10er-Packung)
Produktabmessungen (L x B x H)7.28 x 4.53 x 2.95 Zoll (für 10er-Packung)
HerstellerB&K LLC

8. Garantieinformationen

For specific warranty details regarding the ProLine 116-502 Gas Ball Valve, please refer to the official ProLine website or contact their customer service directly. Warranty terms typically cover manufacturing defects under normal use and service.

9. Kundendienst

If you have any questions, require technical assistance, or need to report an issue with your ProLine 116-502 Gas Ball Valve, please contact ProLine customer support through their official channels. Always provide the model number (116-502) when seeking support.

Für allgemeine Anfragen besuchen Sie bitte die ProLine brand page on Amazon.

Zugehörige Dokumente - 116-502

Vorview Manuell zur Verwendung von PROLINE PGH4FGL-FR: Plaque de cuisson au gas
Lesen Sie die vollständige Gebrauchsanleitung für die Gaskochplatte PROLINE PGH4FGL-FR. Anweisungen zur Installation, Verwendung, Bedienung und Sicherheit.
Vorview Proline Inline-Gebläse (1300 CFM-Modell) Installationsanleitung
Ausführliche Installationsanleitung für den Proline Inline-Gebläse (Modell 1300 CFM), die Inspektion, Montage, Kanalanschluss, Stromverkabelung, Sicherheitsvorkehrungen, Garantie und Rückgabebestimmungen umfasst.
Vorview Proline Gas Range LP Conversion Manual
Detailed instructions for converting Proline gas ranges, including PLSR and PLST models, from natural gas to liquid propane (LP). This manual covers essential steps such as adjusting regulator pressure, changing burner orifices, and replacing oven orifices, with specific guidance for various Proline series.
Vorview Proline PLGL Vortex Insert Range Hood Installation Manual
Comprehensive installation manual for the Proline PLGL Vortex Insert Range Hood, covering safety, pre-installation, ducting, mounting, maintenance, and warranty information.
Vorview Proline BBQ Wall Mount Range Hood Installation Manual & User Guide
Comprehensive installation guide and user manual for Proline BBQ Wall Mount Range Hoods (PLGW BBQ.Pro WC, PLGW BBQ.Ultra WC), covering safety, installation steps, operation, and maintenance.
Vorview PROLINE HPO15W: Nutzungshinweise und Sicherheitsanweisungen
Komplette Gebrauchsanweisung für den elektrischen PROLINE-Chauffeur, Modell HPO15W. Enthält Anweisungen zur Sicherheit, Verwendung, Bedienung und technischen Daten.