1. Einleitung

This manual provides detailed instructions for the AMTAST AMT158 Portable Water Activity Meter. It covers the product's features, technical specifications, proper setup, operational procedures, maintenance guidelines, and troubleshooting steps. Please read this manual thoroughly before using the device to ensure accurate measurements and safe operation.

2. Produktüberschreitungview

2.1 Hauptmerkmale

  • Leicht und tragbar: Weighing approximately 275 grams, the meter is designed for easy transport and on-the-go testing.
  • Accurate & Reliable Measurements: Offers a measurement range of 0-1.0aw with a resolution of ±0.01aw and an accuracy of ±0.02aw for precise water activity analysis.
  • Integrierter Sensor: Features a non-conductive humidity sensor and integrated readings within a single unit, simplifying the measurement process.
  • Quick Testing Process: Provides rapid results, completing water activity measurements within approximately 5 minutes.
  • Convenient Display & Functions: Equipped with a 6-digit backlit LCD screen displaying both water activity (aw) and temperature simultaneously. Includes automatic and manual shut-off options, and a low battery indicator.

2.2 Komponenten

The AMTAST AMT158 Water Activity Meter package typically includes the main unit (host), a sample plate, a portable carrying bag, and this instruction manual.

AMTAST AMT158 Water Activity Meter in a laboratory setting
Abbildung 1: AMTAST AMT158 Water Activity Meter in a laboratory setting, illustrating its function to measure free water activity for food and medicine preservation. The image also shows a sample plate, which is a key component.

3. Spezifikationen

ParameterWert
Messbereich0 ~ 1.0aw
Auflösung±0.01aw
Genauigkeit±0.02aw
Sampling Zeit5 Minuten
Betriebstemperatur0 ~ 50℃ (32 ~ 122℉)
Luftfeuchtigkeit bei Betrieb<95%RH (nicht kondensierend)
Stromversorgung2 x 1.5V AAA Size (UM-4) Battery
Maße145 x 77 x 30M (5.7 x 3.0 x 1.2 Zoll)
Gewicht (ohne Batterien)275 g (0.61 Pfund)
Diagram showing the dimensions and specifications of the AMTAST AMT158 Water Activity Meter
Abbildung 2: Diagram illustrating the physical dimensions (5.7 inches height, 3.0 inches width) and key technical specifications of the AMTAST AMT158 Water Activity Meter.

4. Einrichtung

4.1 Einlegen der Batterie

  1. Suchen Sie die Abdeckung des Batteriefachs auf der Rückseite des Geräts.
  2. Schieben oder lösen Sie die Abdeckung, um sie zu öffnen.
  3. Insert two (2) 1.5V AAA (UM-4) batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
  4. Bringen Sie den Batteriefachdeckel wieder fest an.

Note: Batteries are not included in the package due to aviation security regulations.

Battery compartment and sensor of the AMTAST AMT158 Water Activity Meter
Abbildung 3: Detaillierte view of the AMTAST AMT158 Water Activity Meter's battery compartment, showing where to insert the 2x1.5V AAA batteries, and the non-conductive humidity sensor.

4.2 Erstinspektion

Before first use, inspect the device for any visible damage. Ensure the sample plate is clean and free from debris. The sensor should also be clean and unobstructed.

5. Bedienung

5.1 Ein-/Ausschalten

  • To power on the device, press the power button (usually marked with a ⑂ symbol). The backlit LCD screen will illuminate.
  • The device features an automatic shut-off function to conserve battery power. To manually shut off the device, press and hold the power button until the display turns off.

5.2 Messung durchführen

  1. Stellen Sie sicher, dass die sample plate is clean and dry.
  2. Place a small, representative sample of the material to be tested onto the sample plate. Ensure the sample covers the sensor area adequately without overflowing.
  3. Close the meter's lid or place the main unit onto the sample plate, ensuring a tight seal to create a closed environment for accurate measurement.
  4. The measurement process will begin automatically or may require a button press (refer to specific on-screen prompts if any). The device will typically take approximately 5 minutes to stabilize and display the final water activity (aw) and temperature readings.
  5. Once the reading is stable, record the displayed values.
  6. After measurement, remove the sample and clean the sample plate and sensor area immediately.
Close-up of the AMTAST AMT158 Water Activity Meter's backlit LCD screen
Abbildung 4: Close-up of the AMTAST AMT158 Water Activity Meter's backlit LCD screen, clearly displaying both the water activity (aw) value and the temperature.
AMTAST AMT158 Water Activity Meter emphasizing quick 5-minute measurement
Abbildung 5: The AMTAST AMT158 Water Activity Meter highlighting its quick and efficient measurement capability, completing tests within 5 minutes.

5.3 Anwendungen

The AMTAST AMT158 Water Activity Meter is suitable for measuring water activity in a wide range of products, including but not limited to:

  • Dried fruits and vegetables
  • Beef jerky and other dried meats
  • Baked goods like cookies
  • Sausages and processed meats
  • Grains, nuts, and spices
Collage of food items illustrating the wide application of the AMTAST AMT158 Water Activity Meter
Abbildung 6: A visual representation of various food products such as dried fruit, beef jerky, cookies, and sausage, demonstrating the broad utility of the AMTAST AMT158 Water Activity Meter in different food applications.

6. Wartung

6.1 Reinigung

  • After each use, carefully clean the sample plate and the area around the sensor with a soft, dry cloth.
  • Do not use abrasive cleaners or solvents, as these can damage the sensor or the device's casing.
  • Ensure no liquid enters the device's internal components.

6.2 Speicherung

Store the meter in a clean, dry environment, away from direct sunlight and extreme temperatures. When storing for extended periods, remove the batteries to prevent leakage.

6.3 Batteriewechsel

When the low battery indicator appears on the display, replace both AAA batteries promptly to ensure continued accurate operation. Refer to Section 4.1 for battery installation instructions.

7. Fehlerbehebung

ProblemMögliche UrsacheLösung
Gerät lässt sich nicht einschaltenLeere oder falsch eingelegte BatterienBatteriepolarität prüfen; gegebenenfalls durch neue Batterien ersetzen.
Ungenaue oder widersprüchliche Messwerte
  • Sensorverschmutzung
  • Unzulässige sampdie Platzierung
  • Device not calibrated (if applicable)
  • Environmental interference (temperature/humidity outside operating range)
  • Reinigen Sie den Sensor und sample plate thoroughly.
  • Stellen Sie sicher, dass die sample covers the sensor and the lid is sealed.
  • If calibration is required, refer to specific calibration instructions (not covered in this general manual).
  • Ensure operating conditions are within specified ranges (0-50℃, <95%RH).
Display shows 'Low Battery'Batterien sind schwachErsetzen Sie beide 1.5V AAA-Batterien.
Gerät piept kontinuierlichPossible internal error or battery issueNehmen Sie die Batterien heraus und setzen Sie sie wieder ein. Sollte das Problem weiterhin bestehen, wenden Sie sich bitte an den Kundendienst.

8. Garantie und Support

Informationen zu Garantie, technischem Support oder Serviceanfragen erhalten Sie beim Hersteller oder Ihrem autorisierten Händler. Bewahren Sie Ihren Kaufbeleg als Kaufnachweis auf.

You can visit the official AMTAST store for more information: AMTAST Store on Amazon

Zugehörige Dokumente - AMT158

Vorview AMTAST Oberflächenrauheitsmessgerät – Bedienungsanleitung
Ausführliche Bedienungsanleitung für das AMTAST Oberflächenrauheitsmessgerät mit detaillierten Informationen zu Funktionen, Bedienung, Wartung, Fehlerbehebung und technischen Spezifikationen für eine präzise Oberflächentexturanalyse.
Vorview AMTAST Bewässerungsuhr: Installations-, Bedienungs- und Fehlerbehebungsleitfaden
Ausführlicher Leitfaden für den AMTAST-Wasserzeitschalter, der das Produkt überviewSpezifikationen, Installation, Einstellungen für das automatische Bewässerungsprogramm, manuelle Bewässerung, Regenverzögerung, Kindersicherung und häufig gestellte Fragen.
Vorview AMT-105 Innen-/Außen-Alarmthermometer – Produktanleitung
Produkthandbuch für das AMTAST AMT-105 Innen-/Außen-Alarmthermometer mit detaillierter Beschreibung der Funktionen, Spezifikationen, Installationsschritte und Bedienungshinweise.
Vorview Amtast AMT620 Labor-pH-Meter – Merkmale und Spezifikationen
Detaillierte Informationen zum Amtast AMT620 Labor-pH-Meter, einschließlich seiner Funktionen wie automatischer/manueller pH-Temperaturkompensation, GLP-Funktion, Datenspeicherung und RS232-Schnittstelle. Spezifikationen für pH-, mV- und Temperaturmessbereiche sowie Genauigkeit werden bereitgestellt.