ACiQ ACiQ-24-AC / ACIQ-24-ACL

ACiQ 16.5 SEER2 Inverter-Klimaanlage & Verdampfersystem – Benutzerhandbuch

Model: ACiQ-24-AC / ACIQ-24-ACL | Brand: ACiQ

1. Einleitung

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your ACiQ High Efficiency 16.5 SEER2 24,000 Cooling BTU Inverter Air Conditioner and Multi-Positional Cased Evaporator Coil System. Please read this manual thoroughly before installation or operation and keep it for future reference.

The ACiQ system is designed to provide optimal cooling performance with advanced inverter technology, ensuring consistent temperature control and energy efficiency. This system includes an outdoor inverter unit, a multi-positional cased evaporator coil, and a smart thermostat for convenient control.

2. Wichtige Sicherheitshinweise

WARNUNG: Unsachgemäße Installation, Einstellung, Änderung, Wartung oder Instandhaltung können Sachschäden, Verletzungen oder Tod verursachen. Beachten Sie die Anweisungen in diesem Handbuch. Für Unterstützung oder weitere Informationen wenden Sie sich bitte an einen qualifizierten Installateur oder Kundendienst.

3. Packungsinhalt

Prüfen Sie bei Erhalt, ob alle Komponenten vorhanden und unbeschädigt sind:

ACiQ Inverter Air Conditioner and Evaporator Coil System with Smart Thermostat

Abbildung 3.1: Überview of the ACiQ Inverter Air Conditioner and Evaporator Coil System, including the outdoor unit, cased evaporator coil, and smart thermostat.

4. Einrichtung und Installation

Installation of this system requires specialized knowledge and tools. It is strongly recommended that installation be performed by a certified HVAC technician to ensure proper function, safety, and warranty validity.

4.1 Unit Placement and Dimensions

Ensure adequate clearance around both the outdoor and indoor units for proper airflow and maintenance access. Refer to the following dimensions for planning:

Diagram showing measurements of ACiQ outdoor unit and evaporator coil

Figure 4.1: Detailed measurements for the ACiQ outdoor unit and evaporator coil, indicating dimensions for installation planning.

4.2 Evaporator Coil Installation

The cased multi-positional evaporator coil is designed for versatile installation in various configurations. It is specifically designed for use with gas furnaces or modular blowers and cannot be substituted for a one-piece air handler.

Evaporator coil with specifications for air flow, pressure, and dimensions

Figure 4.2: Specifications for the ACiQ evaporator coil, including air flow, pressure, and physical dimensions.

4.3 Elektrische Anschlüsse

The system requires a 208-230 voltage, 1-Phase, 60Hz electrical supply. All electrical wiring must comply with local and national electrical codes. Ensure proper circuit breaker sizing and wiring gauge for the unit's power requirements.

4.4 Kältemittelleitungen

This system uses R 410A refrigerant. Proper evacuation and charging procedures are critical for system performance and longevity. This process must be performed by a licensed HVAC technician.

5. Bedienungsanleitung

Your ACiQ system is controlled by the included Cielo Smart Thermostat, designed for user convenience and energy efficiency.

5.1 Cielo Smart Thermostat Overview

The Cielo Smart Thermostat allows you to manage your cooling and heating settings efficiently. It ensures your system runs only when needed, helping to reduce energy consumption without compromising comfort.

Cielo Smart Thermostat and its mobile app interface

Figure 5.1: The Cielo Smart Thermostat, illustrating its sleek design and integration with a mobile application for remote control.

5.2 Thermostat Features and Controls

The thermostat offers various features for precise climate control and smart home integration:

Diagram of Cielo Smart Thermostat features including mode, humidity, set points, and smart home integrations

Figure 5.2: An illustrative diagram detailing the various features and control points of the Cielo Smart Thermostat, including its compatibility with popular smart home platforms.

6. Wartung

Regular maintenance ensures the longevity and efficiency of your ACiQ system. Always disconnect power to the unit before performing any maintenance.

6.1 Air Filter Replacement/Cleaning

Check and clean or replace the air filter in your furnace or air handler every 1-3 months, or more frequently if you have pets or allergies. A dirty filter restricts airflow and reduces efficiency.

6.2 Outdoor Unit Coil Cleaning

Periodically inspect the outdoor unit's condenser coil for dirt, leaves, and debris. Gently clean the coil with a soft brush or hose. Avoid bending the fins. Ensure the area around the outdoor unit is clear of obstructions.

Close-up of the ACiQ outdoor unit's fan and coil

Abbildung 6.1: Eine Nahaufnahme view of the ACiQ outdoor unit, highlighting the fan and condenser coil, which require periodic cleaning for optimal performance.

6.3 Professionelle Wartung

It is recommended to have a qualified HVAC technician perform annual maintenance on your system. This includes checking refrigerant levels, electrical connections, and overall system performance.

7. Fehlerbehebung

Bevor Sie den Kundendienst kontaktieren, ...view Die folgenden häufigen Probleme und ihre Lösungen:

ProblemMögliche UrsacheLösung
System kühlt/heizt nichtThermostat settings incorrect, dirty air filter, tripped circuit breaker, outdoor unit obstructed.Check thermostat mode and temperature settings. Clean/replace air filter. Reset circuit breaker. Clear obstructions around outdoor unit.
Schwacher LuftstromDirty air filter, blocked return air vents, duct leaks.Clean/replace air filter. Ensure vents are open and unobstructed. Inspect ducts for leaks (professional service recommended).
Ungewöhnliche GeräuscheLoose parts, fan motor issues, refrigerant issues.Turn off unit and inspect for loose panels or debris. If noise persists, contact a qualified technician.
System cycles on and off frequentlyOversized unit, low refrigerant, dirty coils.Ensure proper sizing during installation. Check for refrigerant leaks and clean coils. Contact a technician for diagnosis.
Leak detection alertKältemittelleck.The system is equipped with leak detection. If an alert occurs, immediately contact a qualified HVAC technician for inspection and repair.

8. Spezifikationen

Key technical specifications for the ACiQ 16.5 SEER2 24,000 BTU Inverter Air Conditioner and Evaporator Coil System:

BesonderheitDetail
MarkeACiQ
ModellnameACiQ-24-AC / ACIQ-24-ACL
Kühlleistung24,000 BTU/h (2 Tonnen)
SEER2-BewertungBis zu 16.5
StromquelleKabelgebundene Elektrik
Bandtage208-230V, 1-Phase, 60Hz
KältemitteltypR 410A
Abmessungen des Außengeräts (B x T x H)35.04" x 13.46" x 26.5"
Abmessungen der Verdampferschlange (B x T x H)17.52" x 20.98" x 17.99"
KontrollmethodeRemote Control (Cielo Smart Thermostat)
AHRI Certification and EnergyGuide label for ACiQ system

Figure 8.1: AHRI Certification and EnergyGuide label, confirming the system's performance ratings and energy efficiency.

9. Garantie und Support

9.1 Garantiebedingungen

The ACiQ system comes with a 10 Jahre Teilegarantie when installed by a qualified technician and registered online with the manufacturer at no additional charge. Please retain your proof of purchase and installation records for warranty claims.

For detailed warranty terms and conditions, please refer to the warranty documentation included with your product or visit the official ACiQ webWebsite.

Warehouse showing packaged AC units ready for shipment

Figure 9.1: Expert packaging of ACiQ units in a warehouse, ensuring product integrity during transit.

Well-kept warehouse interior with organized product shelving

Abbildung 9.2: Innenraum view of a well-maintained ACiQ warehouse, demonstrating careful handling and storage of products.

9.2 Kundendienst

For technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact ACiQ customer support. Contact information can typically be found on the manufacturer's webauf der Website oder auf der Produktverpackung.

When contacting support, please have your model number (ACiQ-24-AC / ACIQ-24-ACL) and purchase date readily available.

10. Zusätzliche Ressourcen

For further information, product updates, or to explore other ACiQ products, please visit the official ACiQ webWebsite:

Visit the ACiQ Store on Amazon

Zugehörige Dokumente - ACiQ-24-AC / ACIQ-24-ACL

Vorview Installationshandbuch für ACiQ Zentralwechselrichtersysteme
Ausführliche Installationsanleitung für ACiQ Central Inverter Klimaanlagen und Wärmepumpensysteme mit detaillierten Informationen zu Sicherheitsvorkehrungen, Kältemittelleitungen, Installation der Außeneinheit, Verkabelung, Leistungsdaten, Luftabsaugung und Testlaufverfahren.
Vorview Installationshandbuch für die Außeneinheit des ACiQ-Zentralwechselrichtersystems
Umfassende Installationsanleitung für ACiQ Central Inverter Systems-Außengeräte. Beschreibt Sicherheitsvorkehrungen, Kältemittelleitungen, Installation der Außengeräte, Verkabelung, Leistungsspezifikationen, Luftabsaugung und Testlaufverfahren. Enthält Modelldetails und wichtige Hinweise zur ordnungsgemäßen Einrichtung.
Vorview Installationshandbuch für die Außeneinheit des ACiQ-Zentralwechselrichtersystems
Umfassendes Installationshandbuch für Außengeräte von ACiQ Central Inverter Systems mit Informationen zu Sicherheitsvorkehrungen, Kältemittelleitungen, Verkabelung, Geräteinstallation und Testverfahren für Modelle wie ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB und anderen.
Vorview Installationshandbuch für ACiQ-Kanalluftbehandlungsgeräte (12–60 BTU/h)
Dieses Installationshandbuch von ACiQ enthält detaillierte Anweisungen für die sichere und korrekte Installation von Kanal-Klimageräten der Modelle 12 bis 60 BTU/h. Es behandelt wichtige Sicherheitsrichtlinien, Geräteplatzierung, Kältemittelleitungen, elektrische Verkabelung, Spezifikationen und Betriebstests, um optimale Leistung und Systemlebensdauer zu gewährleisten.