ACiQ ACiQ-48-AC

ACiQ 4 Tonnen 15.5 SEER2 Zentral-Klimaanlage – Benutzerhandbuch

Model: ACiQ-48-AC / ACIQ-60-ACL / IKIC51

1. Einleitung

This manual provides essential information for the safe and efficient operation, installation, and maintenance of your ACiQ 4 Ton 15.5 SEER2 High Efficiency Central Air Conditioner System. Please read this manual thoroughly before installation and use, and retain it for future reference. Proper installation and maintenance are crucial for optimal performance and longevity of the unit.

2. Sicherheitshinweise

Wichtige Sicherheitshinweise:

3. Produktüberschreitungview und Funktionen

The ACiQ 4 Ton 15.5 SEER2 Central Air Conditioner System is designed for high-efficiency cooling, featuring inverter technology for precise temperature control and energy savings. This system includes an outdoor condenser, an indoor multi-positional evaporator cased coil, and a comprehensive installation kit.

Hauptmerkmale:

Enthaltene Komponenten:

The complete system includes the following components:

ACiQ 4 Ton Central Air Conditioner System components

Abbildung 3.1: Überview of the ACiQ 4 Ton Central Air Conditioner System, showing the outdoor condenser, indoor evaporator coil, smart thermostat, and various installation kit components.

ACiQ Split System Installation Kit components

Abbildung 3.2: Detaillierte view of the ACiQ Split System Installation Kit, including the insulated line set, electrical whip, disconnect switch, surge protector, and smart thermostat.

ACiQ Air Conditioner Condenser Unit Features

Abbildung 3.3: Close-up of the ACiQ outdoor condenser unit, highlighting its robust construction and fan design.

4. Einrichtung und Installation

Professionelle Installation erforderlich: Due to the complexity of HVAC systems, installation and initial setup of this ACiQ unit must be performed by a certified and qualified HVAC technician. Attempting to install the system without proper training and tools can lead to property damage, personal injury, and void the product warranty.

Der Installationsprozess umfasst typischerweise Folgendes:

  1. Standortauswahl: Choosing appropriate locations for the outdoor condenser and indoor evaporator coil, ensuring adequate airflow and drainage.
  2. Montageeinheiten: Securely mounting the outdoor condenser (using the provided wall mount bracket if applicable) and positioning the indoor evaporator coil.
  3. Kältemittelleitungsanschluss: Connecting the insulated line set between the indoor and outdoor units, ensuring proper brazing and leak testing.
  4. Elektroverkabelung: Connecting the electrical whip, disconnect switch, and surge protector according to local electrical codes and the unit's wiring diagram.
  5. Kondensatableitung: Installing proper drainage for the indoor evaporator coil.
  6. Vacuum and Charging: Evacuating the refrigerant lines and charging the system with the correct amount of R410A refrigerant.
  7. Thermostatinstallation: Wiring and configuring the Smart WiFi Thermostat.
  8. Systemtest: Performing a comprehensive test run to ensure all components are functioning correctly and efficiently.

Refer to the detailed installation guide provided to your HVAC technician for specific instructions and diagrams.

5. Bedienungsanleitung

Your ACiQ system is controlled by the included Smart WiFi Thermostat. Once installed and configured by a professional, operating the system is straightforward.

Smart WiFi Thermostat Operation:

The thermostat allows you to control various aspects of your air conditioning system. Consult the separate thermostat user manual for detailed instructions on its specific features, including:

Smart WiFi Thermostat features and interface

Abbildung 5.1: Diagram illustrating the features and interface of the Smart WiFi Thermostat, including mode, humidity, temperature settings, and connectivity options.

For optimal performance, set the thermostat to a comfortable temperature and avoid frequent, drastic changes. The inverter technology will maintain the set temperature efficiently.

6. Wartung

Regular maintenance is essential to ensure the longevity, efficiency, and optimal performance of your ACiQ air conditioning system. Some maintenance tasks can be performed by the homeowner, while others require a qualified technician.

Benutzerverwaltung (monatlich/vierteljährlich):

Professionelle Wartung (jährlich):

Es wird dringend empfohlen, die jährliche Wartung von einem qualifizierten HLK-Techniker durchführen zu lassen. Dies umfasst in der Regel Folgendes:

7. Fehlerbehebung

Bevor Sie einen Servicetechniker kontaktieren, bezview the following common issues and their potential solutions. For complex problems, always consult a qualified HVAC professional.

ProblemMögliche UrsacheLösung
System Not Cooling
  • Thermostat falsch eingestellt
  • Schmutziger Luftfilter
  • Außengerät blockiert
  • Stromversorgungsproblem
  • Refrigerant leak (system alert)
  • Check thermostat settings (mode, temperature).
  • Luftfilter reinigen oder ersetzen.
  • Clear debris from outdoor unit.
  • Check circuit breaker; ensure disconnect switch is ON.
  • Wenden Sie sich zur Inspektion und Reparatur an einen qualifizierten Techniker.
Schwacher Luftstrom
  • Schmutziger Luftfilter
  • Verstopfte Rückluftöffnungen
  • Probleme mit der Rohrleitung
  • Luftfilter reinigen oder ersetzen.
  • Ensure all return air vents are open and unobstructed.
  • Consult a technician to inspect ductwork.
Ungewöhnliche Geräusche
  • Lose Teile
  • Schmutz im Lüfter
  • Motorprobleme
  • Turn off unit and inspect for loose panels or debris.
  • If noise persists or is severe, contact a technician.
Water Leakage (Indoor Unit)
  • Verstopfte Kondensatablaufleitung
  • Frozen evaporator coil
  • Reinigen Sie die Kondensatablaufleitung.
  • Turn off cooling and allow coil to defrost; check airflow and refrigerant levels. Contact technician if problem persists.

If the problem persists after attempting these solutions, or if you encounter any other issues, contact a qualified HVAC service technician.

8. Spezifikationen

Detailed technical specifications for the ACiQ 4 Ton 15.5 SEER2 Central Air Conditioner System:

SpezifikationWert
MarkeACiQ
ModellnummernACiQ-48-AC / ACIQ-60-ACL / IKIC51
Kapazität4 Tonnen (48,000 BTU/h)
Effizienz (SEER2)15.5 SEER2
KältemitteltypR410A
Bandtage230 Volt
Wastage4000 Watt
Geräuschpegel56 dB
Abmessungen der Außeneinheit (T x B x H)16.14" x 37.24" x 52.48"
Indoor Coil Dimensions (W x D x H)24.49" x 20.98" x 27.99" (622 x 533 x 711 mm)
InstallationstypGeteiltes System
FormfaktorZentrale Split-Klimaanlage
FiltertypWashable, Reusable Mesh Filter
BodenflächenabdeckungUngefähr 2400 Quadratmeter
Besondere MerkmaleWechselrichter, intelligente Sensoren, Goldlamellen-Wärmetauscher, extrem leise, für alle Klimazonen geeignet
Dimensions of ACiQ outdoor condenser and indoor evaporator coil

Abbildung 8.1: Dimensional measurements for the ACiQ outdoor condenser unit and the indoor evaporator coil.

Specifications for ACiQ evaporator coil

Abbildung 8.2: Detailed specifications for the ACiQ evaporator coil, including air flow, pressure, dehumidification, and dimensions.

AHRI Rating Conditions and EnergyGuide label for ACiQ system

Abbildung 8.3: AHRI (Air-Conditioning, Heating, and Refrigeration Institute) certification details and EnergyGuide label, confirming the system's efficiency rating.

9. Garantie und Support

Garantiebedingungen: The ACiQ system comes with a 7 Jahre Teilegarantie und ein 12 Jahre Kompressorgarantie. This warranty is valid when the unit is installed by a qualified technician and registered online with the manufacturer. Please ensure your installer registers the product to activate the full warranty coverage.

Kundendienst: For technical assistance, warranty claims, or to locate a certified service provider, please refer to the contact information provided on the ACiQ official webSie können auch die Website oder die mit Ihrem Kauf gelieferte Dokumentation besuchen. ACiQ Store on Amazon für weitere Informationen.

Zugehörige Dokumente - ACiQ-48-AC

Vorview Installationshandbuch für die Außeneinheit des ACiQ-Zentralwechselrichtersystems
Umfassende Installationsanleitung für ACiQ Central Inverter Systems-Außengeräte. Beschreibt Sicherheitsvorkehrungen, Kältemittelleitungen, Installation der Außengeräte, Verkabelung, Leistungsspezifikationen, Luftabsaugung und Testlaufverfahren. Enthält Modelldetails und wichtige Hinweise zur ordnungsgemäßen Einrichtung.
Vorview Installationshandbuch für ACiQ Zentralwechselrichtersysteme
Ausführliche Installationsanleitung für ACiQ Central Inverter Klimaanlagen und Wärmepumpensysteme mit detaillierten Informationen zu Sicherheitsvorkehrungen, Kältemittelleitungen, Installation der Außeneinheit, Verkabelung, Leistungsdaten, Luftabsaugung und Testlaufverfahren.
Vorview Installationshandbuch für die Außeneinheit des ACiQ-Zentralwechselrichtersystems
Umfassendes Installationshandbuch für Außengeräte von ACiQ Central Inverter Systems mit Informationen zu Sicherheitsvorkehrungen, Kältemittelleitungen, Verkabelung, Geräteinstallation und Testverfahren für Modelle wie ACiQ-18-AC, ACiQ-24-AC, ACiQ-18-EHPB und anderen.
Vorview Technischer Verkaufsleitfaden für ACiQ R32-Einheitsluftbehandlungs- und Wärmepumpenkondensatoren
Dieser technische Verkaufsleitfaden enthält detaillierte Spezifikationen, Leistungsdaten, Abmessungen und Schaltpläne für die ACiQ R32 Unitary Air Handler- und Wärmepumpenkondensatorserie und deckt die Modelle ACiQ-24/36/48/60-AH32 und ACiQ-24/36/48/60-HP32 ab.
Vorview Installationshandbuch für ACiQ-Kanalluftbehandlungsgeräte (12–60 BTU/h)
Dieses Installationshandbuch von ACiQ enthält detaillierte Anweisungen für die sichere und korrekte Installation von Kanal-Klimageräten der Modelle 12 bis 60 BTU/h. Es behandelt wichtige Sicherheitsrichtlinien, Geräteplatzierung, Kältemittelleitungen, elektrische Verkabelung, Spezifikationen und Betriebstests, um optimale Leistung und Systemlebensdauer zu gewährleisten.
Vorview ACiQ Next Gen Kanal-Wärmepumpensystem – Kurzanleitung
Schnellstartanleitung für das ACiQ Next Gen Kanalwärmepumpensystem mit Schaltplänen, Thermostatanschlüssen und DIP-Schaltereinstellungen für verschiedene Installationsszenarien.