1. Wichtige Sicherheitshinweise
Please read and understand all instructions and warnings in this manual before installing, operating, or servicing this heater. Failure to follow these instructions may result in property damage, personal injury, or death.
- Dieses Heizgerät ist nur für die Verwendung in Innenräumen konzipiert.
- Propane Fuel Only: This appliance operates exclusively on liquid propane gas. Do not attempt to use any other fuel type.
- Vent-Free Operation: This is a vent-free appliance. Ensure adequate ventilation as specified in local codes and this manual.
- Professionelle Installation: Installation und Wartung müssen von einem qualifizierten Installateur, einer Serviceagentur oder dem Gaslieferanten durchgeführt werden.
- Altitude Restriction: Vent-free heaters do not operate reliably at elevations above 4,500 feet altitude.
- Sauerstoffmangelsensor (ODS): This heater is equipped with an ODS safety pilot system designed to shut off the heater if oxygen levels in the room become too low. Do not tamper with or bypass this safety feature.
- Abstand zu brennbaren Stoffen: Maintain proper clearances from combustible materials as indicated in the installation section.
- Einwohner Kaliforniens: This item is not for sale to residents in California. Check your local regulations before purchasing und Installation.
2. Produktüberschreitungview
The ProCom Heating ML200HBA-B is a 20,000 BTU liquid propane ventless blue flame heater designed to provide reliable supplemental heat for areas up to 950 square feet. It features manual controls and a push-button piezo ignition system, requiring no electricity for operation.

Abbildung 2.1: Vorderseite view of the ProCom Heating ML200HBA-B Ventless Blue Flame Heater with base feet installed.
Hauptmerkmale:
- 20,000 BTU maximum heat output, heating up to 950 sq. ft.
- Operates on Liquid Propane only.
- No electricity required for operation, ideal during power outages.
- Push-button Piezo ignition for easy startup.
- Manual control with three heat settings: Low, Medium, High.
- Integrated Oxygen Depletion Sensor (ODS) for safety with automatic shut-off.
- Includes base feet for floor standing and a wall mounting bracket for wall installation.

Figure 2.2: Visual summary of the heater's operational features and benefits.
3. Einrichtung und Installation
This heater can be installed as a freestanding unit using the included base feet or permanently mounted to a wall using the provided wall bracket. Always ensure installation is performed by a qualified professional and adheres to all local codes and regulations.
3.1 Auspacken und Prüfen
- Carefully remove the heater and all components from the packaging.
- Inspect the heater for any shipping damage. If damage is found, do not install or operate the heater. Contact your dealer immediately.
- Verify that all included components are present: heater unit, base feet, wall mounting bracket, and necessary hardware (screws for feet and bracket).
3.2 Standortanforderungen
- Select a location that allows for proper clearances from combustible materials (walls, furniture, drapes, etc.). Refer to the heater's labels for specific clearance requirements.
- Ensure the room has adequate air circulation for vent-free operation.
- Do not install in bathrooms, bedrooms, or recreational vehicles.
- Avoid areas with high drafts or where the heater could be exposed to water.

Abbildung 3.1: Bspample of the heater installed on a wall, demonstrating its compact profile.
3.3 Attaching Base Feet (for Freestanding Use)
- Carefully lay the heater on its back on a soft, protected surface.
- Align the base feet with the pre-drilled holes on the bottom of the heater.
- Secure the feet using the provided screws. Ensure they are tightened firmly.

Figure 3.2: Detail of the blue flame technology and the included base feet for stable placement.
3.4 Wandmontage (optional)
- Refer to the detailed instructions included with the wall mounting bracket for proper installation.
- Ensure the wall can support the weight of the heater and that mounting hardware is appropriate for the wall material.
3.5 Gasanschluss
- Connect the heater to a liquid propane supply line. This connection must be made by a qualified professional.
- Ensure all gas connections are leak-tested using a non-corrosive leak detection solution. Never use an open flame to check for leaks.
- The heater operates at a specific gas pressure. Ensure the supply pressure is within the specified range for safe operation.
4. Bedienungsanleitung
This heater features manual controls for ignition and heat output. No electrical power is required for basic operation.
4.1 Lighting the Heater (Piezo Ignition)
- Stellen Sie sicher, dass das Gaszufuhrventil geöffnet ist.
- Locate the control knob and the ignitor button on the heater.
- Push in and turn the control knob counter-clockwise to the 'PILOT IGN' position.
- While holding the control knob in, repeatedly press the ignitor button until the pilot flame ignites. You should see a small blue flame at the pilot burner.
- Continue to hold the control knob in for approximately 30-60 seconds after the pilot flame ignites. This allows the thermocouple to heat up and hold the pilot valve open.
- Release the control knob. If the pilot flame extinguishes, repeat steps 3-5.
- Once the pilot flame is stable, push in and turn the control knob counter-clockwise to your desired heat setting (LOW, MEDIUM, or HIGH). The main burner will ignite.

Figure 4.1: Manual control knob and ignitor button for operating the heater.
4.2 Einstellen der Heizleistung
To adjust the heat output, simply push in and turn the control knob to one of the three settings: LOW, MEDIUM, or HIGH. The heater will adjust its flame intensity accordingly.
4.3 Ausschalten der Heizung
To turn off the heater, push in and turn the control knob clockwise to the 'OFF' position. Ensure the main burner and pilot flame are extinguished. For extended periods of non-use, also close the main gas supply valve.
5. Wartung
Regular maintenance ensures the safe and efficient operation of your heater. Always disconnect the gas supply and allow the heater to cool completely before performing any maintenance.
- Reinigung: Periodically clean the exterior surfaces of the heater with a soft, damp Tuch. Keine Scheuer- oder Lösungsmittel verwenden.
- Burner and Pilot Area: Keep the burner ports and pilot assembly clean and free of dust, lint, or debris. A soft brush or vacuum cleaner can be used. Blocked ports can affect performance and safety.
- Jährliche Inspektion: It is recommended to have the heater inspected annually by a qualified service technician to ensure all components are functioning correctly and safely.
- Do not paint any part of the heater.
6. Fehlerbehebung
If you experience issues with your heater, consult the following troubleshooting guide. For problems not listed here or if solutions do not resolve the issue, contact a qualified service technician.
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Pilot leuchtet nicht | Keine Gasversorgung Luft in der Gasleitung Pilot orifice clogged Zünder zündet nicht | Ensure gas supply valve is open Bleed air from line by holding pilot knob in for longer Clean pilot orifice Check ignitor electrode for damage or proper gap |
| Pilot lights but will not stay lit when knob is released | Thermocouple not heating sufficiently Lockerer Thermoelementanschluss Fehlerhaftes Thermoelement | Hold control knob in longer after pilot lights Check and tighten thermocouple connection Replace thermocouple (professional service recommended) |
| Hauptbrenner zündet nicht | Pilot not lit Main burner orifice clogged Niedriger Gasdruck | Ensure pilot is lit and stable Clean main burner orifice Verify adequate gas supply pressure |
| Heater produces an odor | Initial burn-off of manufacturing oils Dust/debris on burner Unzureichende Belüftung | Operate heater in a well-ventilated area for a few hours Clean burner area Sorgen Sie für ausreichende Raumbelüftung |
| Heizung schaltet sich unerwartet ab | Oxygen Depletion Sensor (ODS) activated Niedriger Gasdruck Zündflamme erloschen | Increase ventilation in the room Gasversorgung prüfen Relight pilot flame |
7. Spezifikationen
Detailed technical specifications for the ProCom Heating ML200HBA-B heater.

Figure 7.1: Product dimensions of the ProCom Heating ML200HBA-B heater.
| Besonderheit | Spezifikation |
|---|---|
| Marke | ProCom |
| Modellnummer | ML200HBA-B |
| Kraftstoffart | Flüssiges Propan |
| Wärmeabgabe | 20,000 BTU/Std. |
| Heizungsabdeckung | Bis zu 950 m². |
| Steuerungstyp | Manual (Low/Medium/High) |
| Zündungsart | Push-button Piezo |
| Sicherheitsfunktionen | Oxygen Depletion Sensor (ODS) with automatic shut-off |
| Stromquelle | Kein Strom erforderlich |
| Montageoptionen | Floor Stand (with included feet), Wall Mount (with included bracket) |
| Produktabmessungen (L x B x H) | 19" x 9" x 24" |
| Artikelgewicht | 23.1 Pfund |
| UPC | 848660008413 |
8. Garantie und Support
For warranty information, technical support, or to inquire about replacement parts, please contact ProCom Heating customer service. Keep your purchase receipt and model number readily available when contacting support.
Kontaktinformationen finden sich üblicherweise auf der Website des Herstellers. webauf der Website oder auf der Produktverpackung.