The TOPGREENER TDHOS5 is a dual-technology sensor switch designed to automatically control bathroom fans and lights. It integrates both Passive Infrared (PIR) motion detection and humidity sensing capabilities. This device helps manage humidity levels to prevent mold and mildew growth while providing convenient, energy-efficient lighting and ventilation control.

This manual provides detailed instructions for the safe installation, operation, and maintenance of your TDHOS5 sensor switch.

2. Sicherheitshinweise

WARNUNG: Um Brände, Stromschläge oder Todesfälle zu vermeiden, schalten Sie vor Beginn der Verkabelungsarbeiten die Stromzufuhr am Sicherungskasten oder Leitungsschutzschalter ab und prüfen Sie, ob der Strom tatsächlich abgeschaltet ist. Die Installation sollte von einem qualifizierten Elektriker oder einer Person mit umfassenden Kenntnissen in der Elektroinstallation durchgeführt werden.

3. Packungsinhalt

Vergewissern Sie sich vor Beginn der Installation, dass alle Komponenten vorhanden sind:

4. Produktmerkmale

The TDHOS5 sensor switch offers the following key features:

TOPGREENER TDHOS5 Sensor Switch Overview

Abbildung 1: Überview of the TOPGREENER TDHOS5 Dual Technology Humidity Sensor Switch, highlighting the humidity sensor, passive infrared motion sensor, light control button, and fan control button.

5. Installation

5.1 Verkabelungsanforderungen

5.2 Verdrahtungsanweisungen

  1. Strom ausschalten: Before starting, turn off the power at the circuit breaker or fuse box to avoid electrical shock.
  2. Drähte identifizieren: Carefully identify the following wires in your electrical box:
    • Hot Wire (Line)
    • Neutral Wire (Required)
    • Load Wire for Light
    • Load Wire for Fan
    • Erdungskabel
  3. Kabel anschließen: Use the provided wire nuts to connect the TDHOS5 switch wires to your house wiring according to the wiring diagram.
    • Verbinden Sie Rot wire from the switch to the Leichte Ladung Draht.
    • Verbinden Sie Blau wire from the switch to the Lüfterlast Draht.
    • Verbinden Sie Schwarz wire from the switch to the Hot (Line) Draht.
    • Verbinden Sie Weiß wire from the switch to the Neutral Draht.
    • Verbinden Sie Grün wire from the switch to the Boden Draht.
  4. Montieren Sie den Schalter: Gently push the wired switch into the wall box. Secure it with the mounting screws.
  5. Faceplate installieren: Attach the desired face cover and wall plate.
  6. Strom wiederherstellen: Schalten Sie den Strom am Leistungsschalter wieder ein.
Wiring Diagram for TOPGREENER TDHOS5 showing neutral wire connection

Figure 2: Basic wiring diagram illustrating the connection of the TDHOS5 switch, emphasizing the required neutral wire and connections for primary load (light) and secondary load (fan).

Full Wiring Diagram for TOPGREENER TDHOS5 in a bathroom setting

Figure 3: Comprehensive wiring diagram showing the TDHOS5 switch connected to a power panel, light fixture, and exhaust fan within a bathroom setup. A neutral wire is essential for this installation.

6. Bedienung

6.1 Erstes Einschalten

Upon initial power-up, the switch will enter a self-test mode. The indicator LEDs may flash. Allow a few moments for the device to initialize.

6.2 Operating Modes (Motion Sensor)

The motion sensor features two operating modes:

To switch between Occupancy and Vacancy Mode: Press and hold both the light and fan buttons for 10 seconds. The green LED indicator will illuminate solid, indicating the mode has been toggled.

6.3 Humidity Sensor Operation

The humidity sensor monitors ambient humidity levels. When the humidity exceeds the preset threshold, the fan will automatically turn on. The fan will continue to run for the set minimum time or until the humidity level drops below the threshold.

Bathroom scene with TOPGREENER TDHOS5 switch, indicating clean and dry environment

Figure 4: The TDHOS5 switch installed in a bathroom, demonstrating its role in maintaining a clean and dry environment by managing humidity.

Steamy bathroom scene with TOPGREENER TDHOS5 switch, showing humidity control

Figure 5: A steamy bathroom environment where the TDHOS5 switch's humidity sensor would activate the fan to reduce moisture and improve air quality.

6.4 einstellbare Einstellungen

The TDHOS5 allows for adjustment of time delay and humidity sensitivity:

TOPGREENER TDHOS5 switch in a laundry room, highlighting automatic operation

Figure 6: The TDHOS5 switch installed in a laundry room, demonstrating its utility for automatic fan control to manage humidity in areas prone to moisture.

7. Wartung

The TOPGREENER TDHOS5 switch requires minimal maintenance.

8. Fehlerbehebung

ProblemMögliche UrsacheLösung
Light/Fan does not turn ON.No power, incorrect wiring, sensor obstructed, incorrect mode.Check circuit breaker. Verify wiring connections. Ensure sensor is clear. Check operating mode (Occupancy/Vacancy).
Light/Fan stays ON too long or turns OFF too quickly.Incorrect time delay setting.Adjust the time delay setting as per the operation instructions.
Fan does not activate with high humidity.Incorrect humidity level setting, sensor obstructed.Adjust the humidity sensitivity setting. Ensure the humidity sensor is not blocked.
Motion sensor is too sensitive or not sensitive enough.Sensorplatzierung, Umgebungsfaktoren.Ensure the sensor has a clear line of sight. Avoid placing near heat sources or drafts.
LED-Anzeige funktioniert nicht.Defektes Gerät.Contact customer support if all other functions are working correctly.

9. Spezifikationen

10. Garantie und Support

TOPGREENER products are designed for reliability and performance. For warranty information or technical support, please refer to the official TOPGREENER webBesuchen Sie die Website oder kontaktieren Sie direkt den Kundenservice. Bewahren Sie Ihren Kaufbeleg als Kaufnachweis für Garantieansprüche auf.

Kontaktinformationen: Besuchen Sie www.topgreener.com Für die aktuellsten Support-Ressourcen und Kontaktdaten.

Zugehörige Dokumente - TDHOS5

Vorview TOPGREENER TDHOS5 Dual-Technologie-Feuchtigkeits-PIR-Bewegungsmelder – Installationsanleitung
Ausführliche Installations- und Programmieranleitung für den TOPGREENER TDHOS5 Dual-Technologie-Feuchtigkeits- und PIR-Bewegungsmelder. Beinhaltet Verkabelung, Einrichtung, Funktionen, Fehlerbehebung und Garantie für eine optimale Steuerung von Badezimmerbeleuchtung und -lüfter.
Vorview TOPGREENER TDHS5 Feuchtigkeitssensor-Lüftersteuerung – Installationsanleitung
Ausführliche Installationsanleitung und Bedienungsanleitung für die TOPGREENER TDHS5 Feuchtigkeitssensor-Lüftersteuerung. Erfahren Sie, wie Sie Ihre feuchtigkeitsgesteuerte Lüftersteuerung anschließen, programmieren und bedienen, um eine optimale Badezimmerbelüftung zu gewährleisten.
Vorview Topgreener TDOS5/TDOS5-NL Installationsanleitung für den Belegungs-/Leerstandssensorschalter
Umfassende Installationsanleitung für den 2-in-1-Belegungs-/Leerstandssensorschalter Topgreener TDOS5/TDOS5-NL. Enthält Spezifikationen, Schaltpläne, Anpassungseinstellungen, Betriebsmodi, Tipps zur Fehlerbehebung und Garantieinformationen.
Vorview TopGreener TSOS5/TWOS5 Präsenzmelder-Schalter – Installationsanleitung
Ausführliche Installationsanleitung für die TopGreener TSOS5 und TWOS5 Präsenzmelderschalter, einschließlich Spezifikationen, Schaltplänen, Bedienung, Fehlerbehebung und Garantieinformationen.
Vorview TopGreener TU21536AC/TU22036AC Ultra High Speed USB Charger Receptacle Installation Guide
Installation instructions, specifications, and compatibility information for the TopGreener TU21536AC/TU22036AC Ultra High Speed Type-A & Type-C USB Charger with 15A/20A Decorator Tamper Resistant Receptacle.
Vorview Top Greener TGSDS3 LED-Dimmer Installationsanleitung
Ausführliche Installationsanleitung für den Top Greener TGSDS3 LED-Dimmer mit detaillierten Informationen zur einpoligen und dreipoligen Verdrahtung, Produktspezifikationen, Bedienungsanleitung und Garantieinformationen.