1. Einleitung
The TOPGREENER TDHOS5 is a dual-technology sensor switch designed to automatically control bathroom fans and lights. It integrates both Passive Infrared (PIR) motion detection and humidity sensing capabilities. This device helps manage humidity levels to prevent mold and mildew growth while providing convenient, energy-efficient lighting and ventilation control.
This manual provides detailed instructions for the safe installation, operation, and maintenance of your TDHOS5 sensor switch.
2. Sicherheitshinweise
WARNUNG: Um Brände, Stromschläge oder Todesfälle zu vermeiden, schalten Sie vor Beginn der Verkabelungsarbeiten die Stromzufuhr am Sicherungskasten oder Leitungsschutzschalter ab und prüfen Sie, ob der Strom tatsächlich abgeschaltet ist. Die Installation sollte von einem qualifizierten Elektriker oder einer Person mit umfassenden Kenntnissen in der Elektroinstallation durchgeführt werden.
- Always disconnect power before servicing or installing the switch.
- Dieses Gerät ist nur für den Innenbereich bestimmt.
- Für die Installation ist ein Neutralleiter erforderlich.
- Stellen Sie sicher, dass alle Kabelverbindungen sicher und ordnungsgemäß isoliert sind.
- Do not exceed the maximum load ratings for the switch (500W for light, 3A for fan).
- Comply with all local and national electrical codes.
3. Packungsinhalt
Vergewissern Sie sich vor Beginn der Installation, dass alle Komponenten vorhanden sind:
- TOPGREENER TDHOS5 Dual Technology Humidity Sensor Switch
- Interchangeable face covers (White, Black, Light Almond - Note: Availability of alternate face covers may vary by package.)
- Wall plate (Note: Wall plate may not be included in all packages.)
- Drahtmuttern
- Bedienungsanleitung
4. Produktmerkmale
The TDHOS5 sensor switch offers the following key features:
- Dual Technology Control: Combines Passive Infrared (PIR) motion sensing and humidity sensing for comprehensive automation.
- Feuchtigkeitskontrolle: Automatically activates the fan when humidity exceeds a preset level and turns it off when humidity returns to normal, preventing mold and mildew.
- Bewegungserkennung: PIR sensor detects occupancy to automatically turn lights and/or fans ON/OFF.
- Betriebsarten: Supports Occupancy Mode (Auto ON/Auto OFF for both light and fan) and Vacancy Mode (Manual ON/Auto OFF for light, Auto ON/Auto OFF for fan).
- Einstellbare Einstellungen: Customizable time delay (15 seconds to 30 minutes) and humidity levels.
- Unabhängige Steuerung: Two single-pole relays allow separate control of the bathroom light and fan.
- LED-Kompatibilität: Compatible with LED bulbs.
- Energieeinsparung: Designed to save energy by up to 40% with motion sensing.
- Breite Abdeckung: Up to 600 square feet with a 180-degree field of view.
- Neutralleiter erforderlich: Requires a neutral wire for proper operation.

Abbildung 1: Überview of the TOPGREENER TDHOS5 Dual Technology Humidity Sensor Switch, highlighting the humidity sensor, passive infrared motion sensor, light control button, and fan control button.
5. Installation
5.1 Verkabelungsanforderungen
- Ein Neutralleiter ist erforderlich.
- Separate switch legs for the light and fan are needed.
- Ensure the electrical box is deep enough to accommodate the switch.
5.2 Verdrahtungsanweisungen
- Strom ausschalten: Before starting, turn off the power at the circuit breaker or fuse box to avoid electrical shock.
- Drähte identifizieren: Carefully identify the following wires in your electrical box:
- Hot Wire (Line)
- Neutral Wire (Required)
- Load Wire for Light
- Load Wire for Fan
- Erdungskabel
- Kabel anschließen: Use the provided wire nuts to connect the TDHOS5 switch wires to your house wiring according to the wiring diagram.
- Verbinden Sie Rot wire from the switch to the Leichte Ladung Draht.
- Verbinden Sie Blau wire from the switch to the Lüfterlast Draht.
- Verbinden Sie Schwarz wire from the switch to the Hot (Line) Draht.
- Verbinden Sie Weiß wire from the switch to the Neutral Draht.
- Verbinden Sie Grün wire from the switch to the Boden Draht.
- Montieren Sie den Schalter: Gently push the wired switch into the wall box. Secure it with the mounting screws.
- Faceplate installieren: Attach the desired face cover and wall plate.
- Strom wiederherstellen: Schalten Sie den Strom am Leistungsschalter wieder ein.

Figure 2: Basic wiring diagram illustrating the connection of the TDHOS5 switch, emphasizing the required neutral wire and connections for primary load (light) and secondary load (fan).

Figure 3: Comprehensive wiring diagram showing the TDHOS5 switch connected to a power panel, light fixture, and exhaust fan within a bathroom setup. A neutral wire is essential for this installation.
6. Bedienung
6.1 Erstes Einschalten
Upon initial power-up, the switch will enter a self-test mode. The indicator LEDs may flash. Allow a few moments for the device to initialize.
6.2 Operating Modes (Motion Sensor)
The motion sensor features two operating modes:
- Occupancy Mode (Default): Provides automatic ON/OFF control for both the light and the fan based on detected motion. When motion is detected, the light and fan turn on. After no motion is detected for the set time delay, they turn off.
- Leerstandsmodus: The light must be turned ON manually. The fan operates automatically based on humidity levels or motion detection. After no motion is detected for the set time delay, the light and fan will turn off automatically.
To switch between Occupancy and Vacancy Mode: Press and hold both the light and fan buttons for 10 seconds. The green LED indicator will illuminate solid, indicating the mode has been toggled.
6.3 Humidity Sensor Operation
The humidity sensor monitors ambient humidity levels. When the humidity exceeds the preset threshold, the fan will automatically turn on. The fan will continue to run for the set minimum time or until the humidity level drops below the threshold.

Figure 4: The TDHOS5 switch installed in a bathroom, demonstrating its role in maintaining a clean and dry environment by managing humidity.

Figure 5: A steamy bathroom environment where the TDHOS5 switch's humidity sensor would activate the fan to reduce moisture and improve air quality.
6.4 einstellbare Einstellungen
The TDHOS5 allows for adjustment of time delay and humidity sensitivity:
- Zeitverzögerung: 4 settings ranging from 15 seconds to 30 minutes. Refer to the specific instructions provided with the product for programming these settings.
- Luftfeuchtigkeit: 3 adjustable levels (Low, Medium, High) to set the humidity threshold for fan activation. Refer to the specific instructions provided with the product for programming these settings.

Figure 6: The TDHOS5 switch installed in a laundry room, demonstrating its utility for automatic fan control to manage humidity in areas prone to moisture.
7. Wartung
The TOPGREENER TDHOS5 switch requires minimal maintenance.
- Reinigung: Um den Schalter zu reinigen, wischen Sie ihn mit einem weichen, fusselfreien Tuch ab.amp Mit einem Tuch abwischen. Keine Scheuermittel oder Lösungsmittel verwenden. Vor der Reinigung sicherstellen, dass das Gerät ausgeschaltet ist.
- Sensorbehinderung: Ensure the humidity sensor and PIR lens are not obstructed by dust, paint, or other objects, as this can affect performance.
- Regelmäßige Kontrollen: Periodically test the functionality of the motion and humidity sensors to ensure they are operating correctly.
8. Fehlerbehebung
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Light/Fan does not turn ON. | No power, incorrect wiring, sensor obstructed, incorrect mode. | Check circuit breaker. Verify wiring connections. Ensure sensor is clear. Check operating mode (Occupancy/Vacancy). |
| Light/Fan stays ON too long or turns OFF too quickly. | Incorrect time delay setting. | Adjust the time delay setting as per the operation instructions. |
| Fan does not activate with high humidity. | Incorrect humidity level setting, sensor obstructed. | Adjust the humidity sensitivity setting. Ensure the humidity sensor is not blocked. |
| Motion sensor is too sensitive or not sensitive enough. | Sensorplatzierung, Umgebungsfaktoren. | Ensure the sensor has a clear line of sight. Avoid placing near heat sources or drafts. |
| LED-Anzeige funktioniert nicht. | Defektes Gerät. | Contact customer support if all other functions are working correctly. |
9. Spezifikationen
- Modell: TDHOS5
- Bandtage: 120 Volt AC
- Wastage (Licht): Bis zu 500 Watt
- Amperage (Fan): Bis zu 3 Amperes
- Material: Thermoplastic Polycarbonate
- Installationsmethode: In-Wall
- Sensortyp: Passive Infrared (PIR) and Humidity Sensor
- Abdeckung: 180 degrees, up to 600 sq ft
- Time Delay Settings: 15 seconds, 5 minutes, 20 minutes, 30 minutes
- Feuchtigkeitsempfindlichkeit: Niedrig, Mittel, Hoch
- Zertifizierungen: UL Listed, CA Title 24 Compliant
- Abmessungen (L x B x H): 47 x 43 x 66 mm (1.85 x 1.7 x 2.6 Zoll)
- Neutralleiter: Erforderlich
10. Garantie und Support
TOPGREENER products are designed for reliability and performance. For warranty information or technical support, please refer to the official TOPGREENER webBesuchen Sie die Website oder kontaktieren Sie direkt den Kundenservice. Bewahren Sie Ihren Kaufbeleg als Kaufnachweis für Garantieansprüche auf.
Kontaktinformationen: Besuchen Sie www.topgreener.com Für die aktuellsten Support-Ressourcen und Kontaktdaten.