VEICHI BC98-Z38

Bedienungsanleitung

BC98-Z38 DC Contactor

1. Einleitung

This manual provides essential information for the safe and effective use of the VEICHI BC98-Z38 DC Contactor. Please read this manual thoroughly before installation, operation, or maintenance to ensure proper functioning and to prevent damage or injury.

2. Produktüberschreitungview

The BC98-Z38 DC Contactor is an industrial electrical component designed for switching DC circuits. It is manufactured by T--E and is suitable for various industrial automation applications.

2.1 Hauptmerkmale

2.2 Components and Identification

Front view of the BC98-Z38 DC Contactor

Abbildung 2.2.1: Vorderseite view of the BC98-Z38 DC Contactor, showing the model number and main terminals (L1, L3, T1, T3).

Abgewinkelte Vorderseite view of the BC98-Z38 DC Contactor

Abbildung 2.2.2: Schräge Frontansicht view of the contactor, providing a clearer perspective of the terminal markings and overall structure.

Von oben nach unten view of the BC98-Z38 DC Contactor

Abbildung 2.2.3: Draufsicht view, highlighting the main power terminals and the coil terminals (A1, A2) for control voltage.

Nahaufnahme view of the coil voltage indicator on the BC98-Z38 DC Contactor

Figure 2.2.4: Close-up of the coil voltage indicator, clearly showing "220V DC" for proper electrical connection.

Seite view of the BC98-Z38 DC Contactor

Abbildung 2.2.5: Seite view, illustrating the auxiliary contacts and mounting points of the contactor.

3. Sicherheitshinweise

Beachten Sie stets die folgenden Sicherheitsvorkehrungen, um Verletzungen oder Schäden an der Ausrüstung zu vermeiden:

4. Einrichtung und Installation

Follow these steps for proper installation of the BC98-Z38 DC Contactor:

  1. Auspacken: Carefully remove the contactor from its original packaging. Inspect for any visible damage during transit.
  2. Montage: Mount the contactor vertically on a DIN rail or a suitable mounting plate using the designated mounting holes. Ensure it is firmly secured to prevent vibration.
  3. Wiring - Power Circuit:
    • Connect the incoming DC power supply to terminals L1 and L3.
    • Connect the load to terminals T1 and T3.
    • Ensure all connections are tight and use appropriate wire gauges for the expected current.
  4. Wiring - Control Circuit:
    • Connect the DC220V control voltage to the coil terminals A1 and A2. Observe polarity if specified on the device.
    • The coil voltage must match the contactor's rating (DC220V).
  5. Überprüfung: Before applying power, double-check all wiring connections against your circuit diagram to ensure correctness and safety.

5. Bedienungsanleitung

The BC98-Z38 DC Contactor operates by energizing its coil, which then closes the main contacts, allowing current to flow through the power circuit.

  1. Einschalten: Sobald Installation und Verkabelung abgeschlossen und überprüft sind, schalten Sie den Steuerstromkreis ein.
  2. Aktivierung der Spule: When the DC220V control voltage is applied to terminals A1 and A2, the contactor coil will energize. You should hear an audible click as the main contacts close.
  3. Power Circuit Activation: With the main contacts closed, the DC power from L1/L3 will be connected to T1/T3, supplying power to the connected load.
  4. Die Spule stromlos machen: To open the main contacts and disconnect the load, remove the DC220V control voltage from terminals A1 and A2. The contactor will de-energize, and the main contacts will open.

Notiz: The contactor is designed for continuous operation within its specified ratings. Avoid frequent rapid cycling beyond its design limits, as this can reduce its lifespan.

6. Wartung

Regular maintenance helps ensure the longevity and reliable operation of your DC contactor. Always disconnect all power before performing any maintenance.

7. Fehlerbehebung

This section provides solutions to common issues you might encounter with the BC98-Z38 DC Contactor.

ProblemMögliche UrsacheLösung
Contactor does not energize (no click)
  • Kein Kontrollbandtage zu A1/A2.
  • Falsche Kontrolllautstärketage (not DC220V).
  • Open circuit in control wiring.
  • Beschädigte Zündspule.
  • Check control power supply.
  • Kontrollvolumen überprüfentage matches DC220V.
  • Überprüfen Sie die Steuerleitungen auf Unterbrechungen oder lose Verbindungen.
  • Test coil resistance; replace contactor if coil is open.
Contactor energizes but load does not receive power
  • No power to L1/L3 terminals.
  • Open circuit in power wiring (T1/T3).
  • Welded or damaged main contacts.
  • Überprüfen Sie die Hauptstromversorgung.
  • Überprüfen Sie die Verkabelung der Last auf Unterbrechungen oder lose Verbindungen.
  • Ersetzen Sie den Schütz, wenn die Kontakte beschädigt sind.
Schütz brummt laut oder überhitzt
  • Falsche Lautstärketage (AC applied to DC coil).
  • Lose Verbindungen.
  • Zu hohe Umgebungstemperatur.
  • Ensure only DC220V is applied to the coil.
  • Alle Klemmverbindungen festziehen.
  • Ensure adequate ventilation around the contactor.

8. Spezifikationen

Key technical specifications for the BC98-Z38 DC Contactor:

9. Support und Kontaktinformationen

For technical assistance, inquiries, or support regarding your VEICHI BC98-Z38 DC Contactor, please refer to the seller's contact information or the manufacturer's official support channels.

This product is supplied in original, unused packaging. For any issues related to product defects or performance, please contact your point of purchase.

Zugehörige Dokumente - BC98-Z38

Vorview HS-Z38 Literature Display Assembly Manual
Assembly instructions and technical specifications for the HS-Z38 Literature Display by Shanghaimuxinmuyeyouxiangongsi. Learn how to safely assemble and use your display stand.
Vorview VEVOR HS-Z38 Literaturdisplay-Baugruppe und Benutzerhandbuch
Ausführliche Montageanleitung, Sicherheitshinweise und technische Daten für das VEVOR HS-Z38 Prospektregal. Erfahren Sie, wie Sie Ihr Prospektregal sicher montieren und verwenden.
Vorview VEICHI Solarpumpensystem Bedienungsanleitung
Umfassendes Handbuch für VEICHI-Solarpumpensysteme mit Informationen zur Auswahl von Solarmodulen, Schaltplänen, Bedienung, Fehlerbehebung und Wartung für effizientes solarbetriebenes Wasserpumpen.
Vorview VEICHI FLink IOT-Erweiterungsmodul IOT-BS4.0-FLink-Spezifikation
Detaillierte Spezifikationen für das VEICHI FLink IOT-Erweiterungsmodul (IOT-BS4.0-FLink), einschließlich Hardwareparameter, Umgebungsanforderungen, mechanische Anzeigen, Softwareparameter, Abmessungen und Installationsanweisungen.
Vorview VEICHI SI23 Solar Pump VFD Manual - Installation, Operation, and Specifications
Comprehensive manual for the VEICHI SI23 Solar Pump Variable Frequency Drive (VFD). Covers safety requirements, installation, wiring, technical specifications, model naming, and disposal instructions for efficient solar-powered water pumping systems.
Vorview VEICHI AC70T Kran-VFD-Handbuch
Ausführliches Handbuch für den VEICHI AC70T Frequenzumrichter für Krananwendungen (VFD), mit detaillierten Informationen zu Installation, Betrieb, Parametern und Wartung für eine optimale Kranleistung.