OFITE Model 900

OFITE Model 900 Viscometer Instruction Manual

Model 900 Rotational Viscometer with Couette Coaxial Cylinder

Marke: OFITE

1. Einleitung

The OFITE Model 900 Viscometer is a highly precise instrument designed for measuring the viscosity of fluid samples. It utilizes a Couette coaxial cylinder system with a transducer to accurately measure the induced rotation of the bob immersed in the fluid. This viscometer offers exceptional control and data acquisition capabilities, making it suitable for research applications. It can be seamlessly integrated with a computer via a serial (RS-232) port and operated using OFITE's proprietary Windows-based ORCADA software, providing a fully automated and user-friendly experience. The compact and portable design, coupled with its robust construction, ensures reliable performance in various environments. Whether you need to analyze viscosity for quality control, product development, or scientific research, the OFITE Model 900 Viscometer delivers accurate and consistent results.

2. Einrichtung

Follow these steps to set up your OFITE Model 900 Viscometer for operation.

2.1 Auspacken und Prüfen

Carefully unpack all components from the carrying case. Verify that all included components are present and undamaged. The standard package includes the Viscometer Unit, Carrying Case, Power Cables, and Calibration Accessories.

OFITE Model 900 Viscometer and accessories neatly packed in a foam-lined carrying case.

Abbildung 1: The OFITE Model 900 Viscometer unit and its accessories, including power cables and a sample container, are securely stored within a protective foam-lined carrying case, ready for transport or setup.

2.2 Komponentenmontage

  1. Place the viscometer unit on a stable, level surface.
  2. Connect the power cable to the viscometer and a suitable power outlet.
  3. If using computer control, connect the serial (RS-232) cable from the viscometer to your computer.
  4. Ensure the bob and rotor cup are clean and properly seated. Refer to the images below for correct placement of the bob and cup assembly.
Seite view of the OFITE Model 900 Viscometer showing the lower section with the rotor cup and bob assembly.

Abbildung 2: Eine Nahaufnahme von der Seite view of the OFITE Model 900 Viscometer, highlighting the lower section where the rotor cup and bob are positioned. This view shows the connection points and the general structure of the measurement area.

Eine andere Seite view of the OFITE Model 900 Viscometer, focusing on the bob and cup area with a control knob visible.

Abbildung 3: This image provides an alternative side perspective of the OFITE Model 900 Viscometer, emphasizing the precise alignment of the bob within the rotor cup. A control knob labeled 'LOW' and 'HIGH' is visible, likely for speed or torque adjustment.

3. Bedienungsanleitung

This section details the steps for performing viscosity measurements using the Model 900 Viscometer.

3.1 Einschalten und erste Überprüfungen

  1. Ensure the viscometer is properly connected to power.
  2. Schalten Sie den Hauptschalter ein, der sich normalerweise auf der Rück- oder Seitenfläche des Geräts befindet.
  3. The display on the front panel should illuminate.
Front view of the OFITE Model 900 Viscometer control panel with a digital display and numerical keypad.

Abbildung 4: The front control panel of the OFITE Model 900 Viscometer, featuring a digital display at the top and a numerical keypad below it. Various function buttons like 'CAL', 'NEXT', 'SET UP', 'MUD', and 'CEM' are also visible, indicating control and calibration options.

3.2 Sample Vorbereitung und Verladung

  1. Prepare your fluid sample according to your testing protocol.
  2. Gießen Sie das s vorsichtigample into the rotor cup, ensuring the bob is fully immersed and the fluid level is appropriate for measurement. Avoid air bubbles.

3.3 Durchführung einer Messung

  1. Using the control panel or the ORCADA software, select the desired test parameters (e.g., shear rate, temperature).
  2. Initiate the measurement cycle. The viscometer will begin rotating the rotor cup, and the transducer will measure the induced angle of rotation of the bob.
  3. Monitor the display for real-time readings or observe the data acquisition through the ORCADA software.
  4. Once the measurement is complete, record the data.

3.4 Data Acquisition and Analysis (with ORCADA Software)

For automated control and comprehensive data analysis, connect the viscometer to a computer running OFITE's ORCADA software. The software allows for:

4. Wartung

Proper maintenance ensures the longevity and accuracy of your Model 900 Viscometer.

4.1 Reinigung

4.2 Kalibrierung

Regular calibration is crucial for maintaining measurement accuracy. Use the provided calibration accessories and follow the calibration procedure outlined in the ORCADA software or a separate calibration guide (if provided by OFITE). It is recommended to calibrate the instrument at regular intervals or if you suspect measurement inaccuracies.

4.3 Speicherung

When not in use, store the viscometer in its carrying case in a clean, dry environment, away from extreme temperatures and direct sunlight.

5. Fehlerbehebung

This section provides solutions to common issues you might encounter with the Model 900 Viscometer.

ProblemMögliche UrsacheLösung
Viscometer does not power onNo power supply; faulty power cable; unit switch offCheck power cable connection; ensure power outlet is functional; turn on main power switch.
Ungenaue MesswerteImproper calibration; dirty bob/cup; incorrect sample preparation; damaged bob/cupPerform calibration; clean bob and cup thoroughly; ensure proper sample loading; inspect bob/cup for damage and replace if necessary.
Software (ORCADA) not connectingRS-232 cable disconnected; incorrect COM port selected; software driver issueVerify RS-232 cable connection; check COM port settings in ORCADA; reinstall software drivers if needed.
Motor dreht sich nichtObstruction in rotor cup; motor faultCheck for and remove any obstructions; if problem persists, contact OFITE support.

6. Spezifikationen

Key technical specifications for the OFITE Model 900 Viscometer:

7. Garantie und Support

For information regarding product warranty, technical support, or service, please refer to the documentation provided with your purchase or visit the official OFITE website. Contacting OFITE directly will ensure you receive accurate and timely assistance for your Model 900 Viscometer.

Zugehörige Dokumente - Modell 900

Vorview OFITE Viskosimeter Modell 900: Bedienungsanleitung zur Messung der Flüssigkeitsviskosität
Ausführliche Bedienungsanleitung für das OFITE Viskosimeter Modell 900 mit detaillierter Beschreibung von Bedienung, Einrichtung, Kalibrierung und Softwareintegration für präzise Viskositätsmessungen von Flüssigkeiten im Labor und im Feld.
Vorview OFITE Thermocup Bedienungsanleitung - Modell Nr. 130-38 Serie
Ausführliche Bedienungsanleitung für OFITE Thermocup-Modelle, einschließlich Einführung, Betriebsverfahren, Wartungsrichtlinien und Sicherheitshinweisen. Betrifft die Modelle Nr. 130-38-20, Nr. 130-38-25, Nr. 130-38-30 und Nr. 130-38-35.
Vorview OFITE Reservoir-Permeabilitätsmessgerät (Teilenummer 127-00) Bedienungsanleitung
Ausführliche Bedienungsanleitung für den OFITE Reservoir Permeability Tester (Teilenummer 127-00) mit detaillierten Angaben zu Spezifikationen, Komponenten, Sicherheitsvorkehrungen, Vorbereitung, Bedienung, Softwarenutzung und Wartung.
Vorview OFITE HTHP-Härtekammer Bedienungsanleitung
Umfassende Bedienungsanleitung für die OFITE HTHP-Aushärtungskammer mit detaillierten Informationen zu Einrichtung, Betrieb, Wartung und Fehlerbehebung für die Modelle Nr. 120-20, Nr. 120-25 und Nr. 120-30.
Vorview OFITE Sicherheitsklasseamp für HTHP-Flüssigkeitsverlustzellen - Bedienungsanleitung Teilenummer 170-92
Bedienungsanleitung für die OFITE-Sicherheitsklasseamp (Teilenummer 170-92) – entwickelt für HTHP-Flüssigkeitsverlustzellen. Enthält Informationen zu Betrieb, Garantie und Rückgaberecht von OFI Testing Equipment, Inc.
Vorview OFITE Hydrogen Sulfide Detection Kit - Instruction Manual
Instruction manual for the OFITE Hydrogen Sulfide Detection Kit (Part No. #145-60). Learn about hydrogen sulfide, kit components, safety precautions, testing procedures, and warranty information.