VOLT BDL-VPL-1053-4-BBZ-ZON

VOLT Stemless Directional Brass Path Light (Bronze) Instruction Manual

Model: BDL-VPL-1053-4-BBZ-ZON

1. Einleitung

Thank you for choosing the VOLT Stemless Directional Brass Path Light. This manual provides essential information for the safe and efficient installation, operation, and maintenance of your new low voltage landscape lighting fixture. This path light is designed for outdoor use, providing widespread illumination for pathways, walkways, gardens, driveways, and patios.

VOLT Stemless Directional Brass Path Light illuminating a pathway at night

Image: The VOLT Stemless Directional Brass Path Light installed along a pathway, providing warm illumination.

2. Sicherheitshinweise

Bitte lesen Sie vor der Installation und Inbetriebnahme alle Anweisungen sorgfältig durch. Die Nichtbeachtung dieser Anweisungen kann zu Stromschlag, Brand oder anderen Gefahren führen. Bewahren Sie diese Anleitung zum späteren Nachschlagen auf.

  • This product is intended for use with a 12V low voltage landscape lighting system. A low voltage transformer (not included) is required for operation.
  • Do not connect directly to 120V household current.
  • Ensure power is disconnected at the transformer before installing or servicing the fixture.
  • All electrical connections must comply with local codes and ordinances. If you are unsure about installation, consult a qualified electrician.
  • Do not operate the fixture with a damaged cord or if the lens is cracked.
  • Halten Sie Kinder und Haustiere vom Installationsbereich fern.
  • This fixture is designed for outdoor use and is water-resistant. However, avoid submerging the fixture in water.

3. Lieferumfang

Im Paket sind folgende Komponenten enthalten:

  • VOLT Stemless Directional Brass Path Light
  • 9-inch Ground Stake
  • Mounting Hardware (for surface mounting)

Notiz: A G4 LED bi-pin bulb and a low voltage transformer are sold separately and are required for full functionality.

4. Funktionen

  • Niedriger Profile Design: Standing 1.96 inches tall with a 2.71-inch diameter, this light minimizes obstruction and risk of damage.
  • Professional Grade Construction: Made from solid cast brass with a bronze finish and a heavy frosted acrylic lens for durability.
  • Lamp Bereit: Designed for use with a G4 LED bi-pin bulb (not included) rated up to 20W, providing 140 degrees of light output.
  • Vielseitige Montage: Includes a 9-inch ground stake for landscape installation and hardware for surface mounting.
  • Korrosionsbeständigkeit: Features a beryllium copper socket for enhanced corrosion resistance.
  • Moisture-Tightness: Machine-threaded body screws onto an O-ring for a secure, moisture-tight seal.
  • UL/cUL-gelistet: Gewährleistet die Einhaltung der Sicherheitsstandards.

5. Spezifikationen

AttributDetail
MarkeVOLT
ModellnameVOLT Stemless Directional Brass Path Light
ModellnummerBDL-VPL-1053-4-BBZ-ZON
FarbeBronze
MaterialMessing, Metall
Technische Daten2.71 Zoll L x 2.71 Zoll B x 1.96 Zoll H
LeuchtenformWeg
StromquelleCorded Electric (Low Voltage)
Bandtage12 Volt (Wechselstrom)
LichtquellentypLED (G4 Bi-pin bulb, not included)
LampensockelG4
Maximal Watttage20W (for G4 LED bi-pin bulb)
InstallationstypSurface Mount, Ground Stake
Verwendung im Innen- und AußenbereichIm Freien
WasserbeständigkeitWasserfest
ZertifizierungenUL/cUL-gelistet

6. Installation

Before beginning installation, ensure the power to your low voltage transformer is turned OFF.

6.1. Installation der Glühbirne

  1. Carefully remove the top cap of the path light by unscrewing it.
  2. Insert a G4 LED bi-pin bulb (sold separately) into the beryllium copper socket. Ensure the pins are fully seated.
  3. Replace the top cap, screwing it firmly to ensure a moisture-tight seal.
Close-up of the VOLT Stemless Directional Brass Path Light

Bild: Eine Nahaufnahme view of the VOLT Stemless Directional Brass Path Light, showing its compact design.

6.2. Montagemöglichkeiten

The VOLT Stemless Directional Brass Path Light offers two primary mounting methods:

6.2.1. Installation der Bodenanker

  1. Thread the path light onto the included 9-inch PVC ground stake.
  2. Select a desired location in your landscape. Ensure the location allows for proper drainage and is clear of underground utilities.
  3. Push the ground stake firmly into the soil until the path light is at the desired height and stable. For hard soil, pre-dig a small pilot hole.
  4. Leiten Sie die niedrige Lautstärketage wire from the path light to your low voltage transformer, ensuring the wire is protected from damage.

6.2.2. Surface Mounting

  1. Identify the desired surface for mounting (e.g., deck, patio edge).
  2. Use the provided mounting hardware to secure the base of the path light to the surface. Pre-drill pilot holes if necessary.
  3. Ensure the fixture is securely fastened and stable.
  4. Leiten Sie die niedrige Lautstärketage wire from the path light to your low voltage transformer, ensuring the wire is protected from damage.

6.3. Wiring to Transformer

  • Schließen Sie den Lautstärkeregler antage wire from the path light to the common and 12V terminals on your low voltage Transformator.
  • Stellen Sie sicher, dass alle Verbindungen fest und sicher sind.
  • Once all fixtures are installed and wired, turn on the power at the transformer.

Video: Dieses Video bietet einen Überblick überview of the VOLT Stemless Brass Bronze Directional Path Light, highlighting its features and demonstrating mounting options. It shows how to attach the light to a ground stake and how to prepare it for surface mounting.

7. Bedienungsanleitung

The VOLT Stemless Directional Brass Path Light operates as part of a low voltage landscape lighting system controlled by a transformer. There are no direct controls on the fixture itself.

  • Once properly installed and connected to a low voltage transformer, the light will turn on and off according to the transformer's settings (e.g., timer, photocell).
  • Ensure the transformer is set to the desired operating schedule.

8. Wartung

Regular maintenance will help ensure the longevity and optimal performance of your path light.

  • Reinigung: Reinigen Sie die Leuchte und die Linse regelmäßig mit einem weichen Tuch.amp cloth to remove dirt, debris, and mineral deposits. Do not use abrasive cleaners.
  • Lampenwechsel: If the bulb burns out, ensure the power to the transformer is off before replacing the G4 LED bi-pin bulb. Follow the bulb installation steps in Section 6.1.
  • Verkabelungsprüfung: Annually inspect wiring for any signs of damage, fraying, or loose connections. Repair or replace as needed.
  • Stabilität der Vorrichtung: Check that the fixture remains securely mounted, whether on a ground stake or surface. Re-secure if loose.

9. Fehlerbehebung

ProblemMögliche UrsacheLösung
Licht geht nicht anKeine Stromversorgung des Transformators
Wackelkontakt
Defekte Glühbirne
Transformer timer/photocell setting
Check power supply to transformer
Inspect and tighten all wire connections
Glühbirne ersetzen
Adjust transformer settings
Licht flackertLose Glühbirne
Wackelkontakt
Inkompatible Glühbirne
Ensure bulb is fully seated
Inspect and tighten all wire connections
Ensure G4 LED bi-pin bulb is compatible with 12V AC systems
Das Licht ist schwachGeringe Lautstärketage vom Transformator
Schmutzige Linse
Glühbirnetage zu niedrig
Check transformer output voltage
Reinigen Sie die Linse
Ersetzen Sie durch ein höherwertigestage G4 LED bi-pin bulb (up to 20W)

10. Garantie und Support

The VOLT Stemless Directional Brass Path Light is backed by a Lebenslange Garantie. Diese Garantie deckt Material- und Verarbeitungsfehler bei normalem Gebrauch ab.

For warranty claims, technical assistance, or any questions regarding your product, please contact VOLT Lighting customer support. Refer to the official VOLT Lighting webDie aktuellen Kontaktdaten finden Sie auf der Website oder in Ihren Kaufunterlagen.

Hersteller: VOLT-Beleuchtung

UPC: 842032134007

Zugehörige Dokumente - BDL-VPL-1053-4-BBZ-ZON

Vorview VOLT VPL-1006 Coachman LED-Wege- und Flächenleuchte – Installationsanleitung
Ausführliche Installationsanleitung für die VOLT VPL-1006 Coachman LED-Wege- und Flächenleuchte. Enthält Sicherheitshinweise, Packungsinhalt, Produktabmessungen und eine detaillierte Schritt-für-Schritt-Montageanleitung.
Vorview VOLT Estate Pendelleuchte aus Messing mit LED-Beleuchtung – Installationsanleitung (VAL-9503-4036-BBZ)
Offizielle Installationsanleitung für die VOLT Estate Pendelleuchte aus Messing mit LED-Beleuchtung (Modell VAL-9503-4036-BBZ). Erfahren Sie, wie Sie Ihre LED-Leuchte mit niedriger Lichtstärke sicher installieren.tage Landschaftsbeleuchtungskörper.
Vorview VOLT 120V LED-Strahler aus Messing mit Gelenk (Bronze) – Installationsanleitung
Detaillierte Installationsanleitung für den VOLT 120V LED-Strahler aus Messing mit Gelenk (Bronze), Modell VAL-204X-LI-BBZ. Enthält wichtige Sicherheitshinweise, Packungsinhalt, Produktabmessungen sowie eine schrittweise Montage- und Verdrahtungsanleitung für die Gartenbeleuchtung.
Vorview VOLT® Micro Dot Light Installation Guide - VHS-6735-10-BBZ
Comprehensive installation guide for the VOLT® Micro Dot Light (Model VHS-6735-10-BBZ). Includes safety warnings, package contents, dimensions, and step-by-step instructions for low voltage landscape lighting installation.
Vorview VOLT Ultra Premium Wandleuchte aus Messingguss – Installationsanleitung
Dieses Dokument enthält die Installationsanleitung für die VOLT Ultra Premium Wandleuchte aus Messingguss (Modell VHS-650-4-BBK). Es umfasst wichtige Sicherheitshinweise, den Lieferumfang, die Produktabmessungen und eine schrittweise Montageanleitung für die Wandleuchte mit niedriger Lautstärke.tage Landschaftsbeleuchtung.
Vorview VOLT® Premium Solar-Spotlight VSAL-9006-BBZ Installationsanleitung