1. Einleitung
The Daytech DA10 Freezer and Refrigerator Door Alarm is designed to alert users when a refrigerator or freezer door has been left open for an extended period. This device helps prevent food spoilage and unnecessary energy consumption by providing timely audible notifications. It features adjustable delay settings, multiple alarm modes, and customizable volume levels to suit various environments and needs.
2. Produktmerkmale
- Delayed Alert: Configurable delay times of 1, 2, 3, or 4 minutes before the alarm activates.
- Dual Ringing Modes: Choose between CHIME mode for a gentle reminder or ALARM mode for a loud alert.
- Einstellbare Lautstärke: Five volume levels, ranging from 0 dB (silent) to 120 dB, allowing customization for different noise environments.
- Warnung bei niedrigem Batteriestand: The alarm provides a shorter beep duration when batteries are low, indicating it's time for replacement.
- Automatische Abschaltung: If the door remains open, the alarm will stop after 30 minutes of continuous activation to conserve battery life.
- Vielseitige Anwendung: Suitable for refrigerators, freezers, garage doors, shed doors, windows, cabinets, and other entry points.

Abbildung 1: Überview of Daytech Freezer Door Alarm features.
3. Packungsinhalt
Bitte überprüfen Sie das Paket, um sicherzustellen, dass alle Artikel vorhanden sind:
- Main Alarm Unit (1x)
- Magnetic Strip (1x)
- AAA-Batterien (2x)
- Double-sided Adhesive Tape (2x sets)
- Befestigungsschrauben (2x)
- Benutzerhandbuch (1x)
Video 1: Auspacken und überview of the Daytech Freezer Door Alarm contents.
4. Einrichtung und Installation
4.1 Einlegen der Batterie
- Open the battery compartment cover on the back of the main alarm unit.
- Legen Sie zwei AAA-Batterien ein und achten Sie dabei auf die richtige Polarität (+/-).
- Schließen Sie den Batteriefachdeckel fest.
4.2 Montage des Melders
The alarm can be mounted using either the provided adhesive tape or screws.
- Clean the surface where the alarm will be installed to ensure it is dry and free of dust or grease.
- Attach the double-sided adhesive tape to the back of both the main alarm unit and the magnetic strip. Alternatively, use the provided screws for a more permanent installation.
- Position the main alarm unit on the door frame or the fixed part of the appliance.
- Position the magnetic strip on the moving part of the door, ensuring that the triangle marks on both the main unit and the magnetic strip are aligned.
- The distance between the main unit and the magnetic strip must be less than or equal to 0.98 inches (2.5 cm) wenn die Tür geschlossen ist.

Figure 2: Step-by-step installation guide for the alarm.

Figure 3: Installation and battery replacement visuals.
5. Bedienungsanleitung
5.1 Ein-/Ausschalten und Modusauswahl
Use the 'CHIME/ALARM/OFF' switch on the side of the main unit to select the desired mode:
- GLOCKEN: The alarm will emit a chime sound when triggered.
- ALARM: The alarm will emit a loud siren sound when triggered.
- AUS: Der Alarm ist ausgeschaltet.
5.2 Setting Delay Time (1-4 Minutes)
Press the 'SET' key on the side of the main unit to cycle through the four delay modes. Each press will confirm the mode with a specific number of beeps:
- Mode 1 (1 beep): Alert after 1 minute, beeps every 15 seconds for 5 seconds until the door closes. (Recommended for refrigerators, basement doors).
- Mode 2 (2 beeps): Alert after 2 minutes, beeps every 10 seconds for 10 seconds until the door closes. (Recommended for garages, shed doors).
- Mode 3 (3 beeps): Alert after 3 minutes, beeps every 5 seconds for 15 seconds until the door closes. (Recommended for windows, cabinet doors).
- Mode 4 (4 beeps): Alert after 4 minutes, beeps every 20 seconds for 15 seconds until the door closes. (Recommended for offices, shop doors).

Figure 4: Four selectable delay modes and their alert patterns.
Video 2: Demonstration of setting the delay modes on the Daytech Freezer Door Alarm.
5.3 Lautstärke anpassen
Use the volume buttons (+/-) on the side of the main unit to adjust the alarm's loudness. There are 5 levels available, from 0 dB (silent) to 120 dB (maximum loudness).
Video 3: Guide to adjusting the volume levels of the Daytech Freezer Door Alarm.
6. Wartung
6.1 Reinigung
Wipe the alarm unit and magnetic strip with a soft, dry cloth. Avoid using harsh chemicals or abrasive cleaners.
6.2 Batteriewechsel
When the low battery warning is activated (shorter beeps), replace the two AAA batteries promptly to ensure continuous operation. Follow the battery installation steps in Section 4.1.
7. Fehlerbehebung
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Der Alarm ertönt nicht. | 1. Die Batterien sind leer oder falsch eingesetzt. 2. Alarm is in 'OFF' mode. 3. Magnetic strip is too far from the main unit. | 1. Replace batteries and check polarity. 2. Switch to 'CHIME' or 'ALARM' mode. 3. Adjust placement to ensure distance is ≤ 0.98 inches (2.5 cm). |
| Alarm sounds too frequently. | Delay time is too short. | Increase the delay time using the 'SET' key (Mode 2, 3, or 4). |
| Alarm is too quiet/loud. | Volume level is not set correctly. | Adjust the volume using the +/- buttons. |
| Die Warnung wegen niedrigem Batteriestand bleibt auch nach dem Batteriewechsel bestehen. | Incorrect battery type or faulty batteries. | Ensure new, alkaline AAA batteries are used. Try a different set of batteries. |
8. Spezifikationen
- Modell: DA10
- Abmessungen: 2.52 x 1.34 x 4.57 Zoll
- Artikelgewicht: 3.98 Unzen
- Energiequelle: 2 x AAA-Batterien (im Lieferumfang enthalten)
- Batteriezellentyp: Alkalisch
- Kontrollmethode: Berühren
- Geräuschpegel: 0-120 Dezibel
- Montageart: Wandmontage (Klebeband/Schrauben)
- Maximale Sensorreichweite: 0.98 Zoll (2.5 cm)
9. Garantie und Support
Daytech products are designed for reliability and performance. For specific warranty information, please refer to the product packaging or contact Daytech customer support. If you encounter any issues or have questions regarding your Daytech DA10 Freezer and Refrigerator Door Alarm, please visit the official Daytech webWebsite oder kontaktieren Sie unser Kundendienstteam für Unterstützung.
Kontaktinformationen:
Please refer to the official Daytech webDie aktuellsten Kontaktdaten finden Sie auf der Website oder der Produktverpackung.