Vertiv GXE3-1000IRT2UXL

Vertiv Liebert GXE3-1000IRT2UXL UPS User Manual

Model: GXE3-1000IRT2UXL

1. Einleitung

The Vertiv Liebert GXE UPS is an in-line dual conversion single-phase inverter designed to provide robust power protection for critical IT equipment. This system ensures continuous and reliable power, safeguarding connected devices from various AC sector disruptions through its advanced inline double conversion technology. Its flexible design allows for both rack-mount and tower configurations, making it suitable for diverse application environments.

2. Sicherheitshinweise

Please read and understand all safety instructions before installing, operating, or maintaining the UPS. Failure to follow these instructions may result in electric shock, fire, or serious injury.

3. Produktüberschreitungview

3.1 Hauptmerkmale

3.2 Visuelle Anleitung

Front view of the Vertiv Liebert GXE3-1000IRT2UXL UPS in tower configuration, showing the LCD display and control buttons.
Abbildung 3.2.1: Vorderseite View of the UPS. This image displays the front panel of the UPS, highlighting the LCD screen and user interface buttons for status monitoring and configuration.
Hinteren view of the Vertiv Liebert GXE3-1000IRT2UXL UPS, showing input power, circuit breaker, and eight IEC C13 output receptacles.
Abbildung 3.2.2: Rückseite View of the UPS. This image shows the back panel, detailing the power input, circuit breaker, and eight IEC C13 output ports for connecting protected devices.
Dreiviertel view of the Vertiv Liebert GXE3-1000IRT2UXL UPS in tower configuration with base stands.
Figure 3.2.3: UPS in Tower Configuration. This perspective view illustrates the UPS standing upright with its included base stands, suitable for tower deployment.
Seite view of the Vertiv Liebert GXE3-1000IRT2UXL UPS in tower configuration, showing the ventilation grilles.
Abbildung 3.2.4: Seite View of the UPS. This image provides a side profile, highlighting the ventilation grilles essential for proper heat dissipation.

4. Einrichtung

4.1 Auspacken und Prüfen

Carefully unpack the UPS and its accessories. Inspect for any shipping damage. Retain the packaging for future use or return.

4.2 Platzierung

Place the UPS in a well-ventilated area, away from direct sunlight, heat sources, and excessive dust or moisture. Ensure sufficient clearance around the unit for proper airflow.

4.3 Configuration (Tower/Rack-Mount)

The GXE3-1000IRT2UXL can be deployed as a tower unit using the included stands or installed in a standard 19-inch rack using an optional rack-mount kit (sold separately). Follow the instructions provided with the rack-mount kit for rack installation.

4.4 Elektrische Anschlüsse

  1. Eingangsleistung: Connect the UPS input power cord to a grounded electrical outlet. Ensure the outlet provides the correct voltage (230V) and current capacity.
  2. Ausgabegeräte: Connect your critical IT equipment (servers, networking devices, etc.) to the IEC C13 output receptacles on the rear of the UPS. Do not overload the UPS beyond its rated capacity (900W).
  3. Kommunikationsanschlüsse: For monitoring and management, connect the appropriate communication cables (USB, RS-232, or optional network card) to your computer or network.

4.5 Erstes Einschalten

After all connections are secure, press the power button on the front panel to turn on the UPS. The LCD display will illuminate, and the UPS will perform a self-test. Allow the batteries to charge for at least 4 hours before connecting critical loads for optimal runtime.

5. Betrieb der USV

5.1 LCD-Display und Steuerung

The user-friendly LCD display provides real-time status information, including input/output voltage, load level, battery capacity, and operational mode. Use the navigation buttons next to the LCD to scroll through menus and configure settings.

5.2-Betriebsmodi

5.3 Softwareverwaltung

For enhanced monitoring and management, install the Vertiv Power Assist software on a connected computer for local control and graceful shutdown. For network-wide management, utilize Vertiv Power Insight or an optional Vertiv Liebert Intellislot IS-UNITY Network Management Card.

6. Wartung

6.1 Batteriewechsel

The Vertiv Liebert GXE3-1000IRT2UXL features hot-swappable internal batteries, allowing for replacement without powering down connected equipment. Refer to the detailed battery replacement guide available on the Vertiv support website for specific instructions. Always use genuine Vertiv replacement batteries.

6.2 Reinigung

Periodically clean the exterior of the UPS with a soft, dry cloth. Ensure ventilation openings are free from dust and debris to maintain proper airflow and prevent overheating.

6.3 Regelmäßige Kontrollen

Regularly check the UPS status via the LCD display or management software. Verify that input and output connections are secure and that the UPS is operating in the desired mode.

7. Fehlerbehebung

This section provides solutions to common issues you may encounter with your UPS. For more complex problems, contact Vertiv technical support.

ProblemMögliche UrsacheLösung
Die USV schaltet sich nicht ein.No input power; UPS circuit breaker tripped; Battery deeply discharged.Check power cord connection and wall outlet. Reset the circuit breaker. Allow UPS to charge for several hours.
Die USV piept ununterbrochen.Overload condition; Low battery.Reduce connected load. Allow batteries to recharge.
Die USV schaltet häufig in den Batteriebetrieb.Instabile Netzstromversorgung; Empfindlichkeitseinstellung zu hoch.Check utility power quality. Adjust UPS input sensitivity via LCD or software.

8. Spezifikationen

AttributWert
ModellnummerGXE3-1000IRT2UXL
Kapazität (VA / W)1000 VA / 900 W.
Eingangslautstärketage230 V
Ausgangsleistungsfaktor0.9
Formfaktor2U Tower / Rack-Mount Convertible
Ausgangsbuchsen8 x IEC60320 C13
TechnologieDual Conversion Online
Efficiency (Online Mode)Bis zu 91%
Efficiency (ECO Mode)Bis zu 96%
Ladezeit< 4 hours to 90% (internal batteries)
Abmessungen (Paket)17.24 x 16.93 x 3.39 Zoll
Artikelgewicht35.2 Pfund
ASINB0DX6YTYFZ
UPC767041034967, 767041034394

9. Garantie und Support

The Vertiv Liebert GXE3-1000IRT2UXL UPS comes with a standard manufacturer's warranty. Please refer to the warranty card included with your product or visit the official Vertiv webAuf der Webseite finden Sie die detaillierten Garantiebedingungen.

Technische Unterstützung

For technical assistance, troubleshooting, or service inquiries, please contact Vertiv customer support. Contact information and support resources can be found on the official Vertiv webWebsite: www.vertiv.com/en-us/support/

Zugehörige Dokumente - GXE3-1000IRT2UXL

Vorview Vertiv Liebert GXE UPS 1-3kVA Installer/User Guide - Installation and Operation
Comprehensive installer and user guide for the Vertiv Liebert GXE UPS 1-3kVA series, covering installation, operation, maintenance, troubleshooting, and specifications for reliable power protection.
Vorview Vertiv Liebert GXE UPS: High Performance Power Protection
Explore the Vertiv Liebert GXE, an essential and affordable online double-conversion UPS system offering robust power protection for 6000 VA to 10000 VA applications. Features include high efficiency, flexible rack/tower mounting, scalable runtime, and advanced management.
Vorview Vertiv Liebert GXT5 USV: Intelligenter und effizienter Stromschutz | Produktübersichtview
Entdecken Sie die Vertiv Liebert GXT5 USV-Serie, die intelligenten und effizienten Stromschutz für unternehmenskritische Anwendungen bietet.view detaillierte Beschreibung seiner Funktionen, Spezifikationen, Familie überview, Servicepakete, Zubehör und Montageoptionen, wobei das kompakte Design, die hohe Effizienz und die fortschrittlichen Managementfunktionen hervorgehoben werden.
Vorview Vertiv Liebert HPM: Hochleistungs-Kühllösungen für Rechenzentren (4–30 kW)
Entdecken Sie die Vertiv Liebert HPM-Serie, die effiziente und zuverlässige Klimatisierungslösungen für Rechenzentren und kritische Umgebungen bietet. Entdecken Sie technische Spezifikationen, Hauptfunktionen und Anwendungen für Kühlleistungen von 4 bis 30 kW.
Vorview Liebert NXL UPS Installation Manual: 250-400kVA, 60Hz
This installation manual provides comprehensive instructions for the setup and installation of the Liebert NXL UPS, covering single-module and multi-module units ranging from 250-400kVA at 60Hz. It details safety precautions, mechanical and electrical installation procedures, environmental considerations, and system composition.
Vorview Versionshinweise zur Liebert IntelliSlot Unity-Kartenfirmware v7.8.0.0
Versionshinweise zur Firmware-Version 7.8.0.0 der Liebert IntelliSlot Unity Card mit detaillierten Angaben zu Kompatibilität, neuen Funktionen, Sicherheitsupdates und bekannten Problemen.