1. Einleitung
This manual provides essential information for the safe and efficient installation, operation, and maintenance of the TRU COMPONENTS Signal Pillar, model TC-12835336. This device is designed for industrial signaling applications, featuring red and green LED indicators with continuous or flashing light modes and an IP65 protection rating.
2. Sicherheitshinweise
- Lesen Sie vor Installation und Betrieb alle Anweisungen sorgfältig durch.
- Die Installation sollte nur von qualifiziertem Personal durchgeführt werden.
- Vor jeglichen Installations-, Wartungs- oder Fehlersucharbeiten muss die Stromversorgung unterbrochen sein.
- Überprüfen Sie das richtige Volumentage (24V) is supplied to prevent damage to the unit.
- Do not expose the device to conditions beyond its specified IP65 rating.
- Vermeiden Sie es, längere Zeit direkt in die Augen mit dem LED-Licht zu blicken.
3. Produktüberschreitungview
The TRU COMPONENTS Signal Pillar TC-12835336 is a robust signaling device with two LED segments (red and green) for clear visual indication in various industrial environments.

Abbildung 1: TRU COMPONENTS Signal Pillar TC-12835336. This image displays the signal pillar with its black base, threaded mounting shaft, and two translucent LED segments: red on top and green below. A bundle of multi-colored wires extends from the base for electrical connection.
Komponenten:
- LED-Segmente: Red and Green, providing visual status.
- Gehäuse: Durable black housing with a diameter of 55 mm.
- Befestigungsgewinde: Für eine sichere Installation.
- Kabelbaum: Multi-colored wires for power and control connections.
4. Spezifikationen
| Besonderheit | Detail |
|---|---|
| Modellnummer | TC-12835336 |
| Helle Farben | Rot, Grün |
| Beleuchtungsmodi | Continuous or Flashing |
| Durchmesser | Ø 55 mm |
| Schutzklasse | IP65 |
| Bandtage | 24 V |
| Hersteller | TRU-KOMPONENTEN |
| Ursprungsland | China |
5. Einrichtung und Installation
- Stromabschaltung: Ensure all power to the installation area is disconnected before beginning.
- Montage: Securely mount the signal pillar using its threaded base. Ensure the mounting surface is stable and capable of supporting the device.
- Verdrahtung: Connect the signal pillar's wires to the appropriate 24V power supply and control system. Refer to the wiring diagram (if provided separately with the product) for specific connections for continuous or flashing modes. Typically, different wires control each LED segment and the flashing function.
- Umweltsiegel: Ensure the IP65 rating is maintained after installation by properly sealing all connections and mounting points, especially in environments where dust or water ingress is a concern.
- Stromanschluss: Once all connections are secure and verified, restore power to the system.
6. Bedienungsanleitung
The TRU COMPONENTS Signal Pillar operates by receiving a 24V signal to illuminate its LED segments. The specific wiring configuration determines whether a segment illuminates continuously or flashes.
- Dauerlicht: Apply 24V to the designated wire for the desired LED segment (e.g., red or green) to achieve continuous illumination.
- Blinklicht: If wired for flashing operation, applying 24V to the corresponding wire will activate the flashing mode for that LED segment. Consult your system's wiring diagram for specific control signals.
- Multiple Segments: Both red and green segments can be activated independently or simultaneously, depending on the control system's design.
7. Wartung
The TRU COMPONENTS Signal Pillar is designed for low maintenance. Regular checks can ensure optimal performance.
- Reinigung: Periodically clean the exterior of the signal pillar with a soft, damp Tuch. Keine Scheuer- oder Lösungsmittel verwenden.
- Inspektion: Regularly inspect the housing and wiring for any signs of damage, wear, or loose connections.
- Dichtungsintegrität: For IP65 rated protection, ensure all seals and cable glands remain intact and properly tightened.
- Stromabschaltung: Trennen Sie vor der Durchführung von Wartungsarbeiten immer die Stromversorgung.
8. Fehlerbehebung
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Signal pillar does not illuminate. | No power supply; incorrect wiring; faulty LED segment. | Check 24V power supply; verify wiring connections against diagram; if power and wiring are correct, the LED segment may require replacement. |
| LED segment illuminates continuously instead of flashing (or vice-versa). | Incorrect wiring for flashing/continuous mode. | Review wiring diagram and ensure correct connections for the desired operating mode. |
| Intermittierender Betrieb. | Lose Kabelverbindung; instabile Stromversorgung. | Inspect all wiring connections for tightness; check power supply stability. |
Wenn die Schritte zur Fehlerbehebung das Problem nicht lösen, wenden Sie sich bitte an den Kundendienst oder einen qualifizierten Techniker.
9. Garantie und Support
For information regarding warranty coverage, technical support, or replacement parts, please refer to the documentation provided with your purchase or contact TRU COMPONENTS customer service. Keep your purchase receipt as proof of purchase.
Manufacturer: TRU COMPONENTS