1. Einleitung
The Tzone PTD601 is an advanced USB RTD Temperature Data Logger designed for precise temperature monitoring across various applications. It features an intuitive interface, an external PT100 probe, and the ability to generate data reports directly via USB without requiring specialized software. This manual provides detailed instructions for the proper setup, operation, and maintenance of your PTD601 data logger.
2. Packungsinhalt
Bitte überprüfen Sie, ob alle unten aufgeführten Artikel in Ihrem Paket enthalten sind. Sollten Artikel fehlen oder beschädigt sein, kontaktieren Sie bitte unseren Kundenservice.
- 1 x Tzone PTD601 Temperature Data Logger
- 1 x PT100 Temperature Probe (1.5m cable)
- 1 x USB-Kabel
- 1 x Benutzerhandbuch (dieses Dokument)
- 1 x Temperature Calibration Certificate (if applicable)
- 1 x Portable Box (for storage and transport)

Abbildung 2.1: Contents of the Tzone PTD601 package, including the data logger, PT100 probe, USB cable, user manual, and portable box.
3. Produktmerkmale
- Großer Temperaturbereich: Measures from -200℃ to 660℃ (-328℉ to 1220℉) with high accuracy.
- Hohe Genauigkeit: ±(0.15+0.002*|t|)℃.
- Large Data Capacity: Speichert bis zu 61,440 Datengruppen.
- Fast Measurement Rate: 1 measurement per second.
- Auto Reports: Generates TXT/CSV/XLS/PDF data reports automatically when connected to a computer, no software required.
- Großer LCD-Bildschirm: Displays current, MAX, MIN, AVG temperature values, temperature trend chart, and recording quantity.
- External PT100 Probe: 1.5m long cable, suitable for diverse measurement scenarios. Supports PT100 and PT1000 probes.
- Multifunktional: Features high and low temperature sound alarms, backlight function, auto-off to save battery, anti-slip design, foldable stand, and hanging design.
- Temperatureinheiten: Supports ℃/℉/K switching.
- Wasserdichtigkeitsklasse IP52: Provides protection against dust and dripping water.

Abbildung 3.1: The Tzone PTD601 displaying its backlight and data hold functions.
4. Einrichtung
4.1 Einlegen der Batterie
The PTD601 is powered by 3x 1.5V AA batteries.
- Suchen Sie das Batteriefach auf der Rückseite des Geräts.
- Öffnen Sie die Abdeckung des Batteriefachs.
- Insert three 1.5V AA batteries, ensuring correct polarity (+/-).
- Schließen Sie den Batteriefachdeckel fest.
4.2 Sondenanschluss
Connect the PT100 temperature probe to the designated port on the top of the data logger. Ensure the connection is firm to prevent inaccurate readings.

Abbildung 4.1: The Tzone PTD601 data logger with the external PT100 probe inserted into test tubes for temperature measurement.
5. Bedienung
5.1 Ein-/Ausschalten
- Zum Einschalten: Die Taste gedrückt halten green power button bis der LCD-Bildschirm aufleuchtet.
- Zum Ausschalten: Die Taste gedrückt halten roter Ein-/Ausschalter until the screen turns off. The device also features an auto-off function to conserve battery life.
5.2 Grundlegende Messung
Once powered on and the probe is connected, the device will immediately begin displaying real-time temperature readings on the large LCD screen.
- The screen shows current temperature, MAX/MIN/AVG values, and a temperature trend chart.
- Position the PT100 probe in the environment or substance you wish to measure.
5.3 Datenhaltefunktion
To temporarily freeze the current temperature reading on the display, press the HALTEN button. Press it again to resume real-time measurements.
5.4 Hintergrundbeleuchtungsfunktion
For operation in low-light conditions, press the Hintergrundbeleuchtung button (often integrated with another function or a dedicated button, refer to device markings) to activate the screen backlight.
6. Parametereinstellungen
The PTD601 allows you to customize various settings through its menu system.

Abbildung 6.1: The Tzone PTD601 displaying its menu for parameter settings, including Sensor Type, Sound, Logging, Auto Off, and Alert.
- Drücken Sie die Speisekarte button (often labeled with an 'M' or similar icon) to enter the settings menu.
- Use the navigation buttons (up/down arrows or similar) to scroll through options such as:
- Sensortyp: Select between PT100 or PT1000 if applicable.
- Klang: Akustische Warnmeldungen aktivieren oder deaktivieren.
- Protokollierung: Configure data logging intervals or start/stop logging.
- Auto Aus: Passen Sie den Auto-Off-Timer an.
- Alarm: Set high and low temperature alarm thresholds.
- Temperatureinheiten: Switch between Celsius (℃), Fahrenheit (℉), or Kelvin (K) using the dedicated ℃/℉/K button or within the menu.
- Drücken Sie die Eingeben button to confirm selections or the Ausfahrt button to leave the menu.
7. Data Management (Auto Reports)
One of the key features of the PTD601 is its ability to generate data reports without requiring proprietary software.
- Ensure the data logger has recorded data.
- Connect the PTD601 to a computer using the provided USB cable.
- The device will be recognized as a removable storage device.
- Navigate to the device's storage. You will find automatically generated data reports in TXT, CSV, XLS, and PDF formats.
- Open these files zu view or analyze your temperature data.
- The device also supports a "regenerate file" function for recovering recent records or deleted data. Refer to the on-screen prompts or the device's internal menu for this option.

Abbildung 7.1: The Tzone PTD601 connected to a computer, demonstrating the automatic generation of data reports in various formats (TXT, CSV, XLS, PDF) without requiring software installation.
8. Alarme
The PTD601 features configurable high and low temperature sound alarms to alert users when temperatures exceed or fall below set thresholds.
- Access the "Alert" option within the Parameter Settings menu (refer to Section 6).
- Set your desired high temperature limit.
- Set your desired low temperature limit.
- Ensure the "Sound" option is enabled in the settings if you wish to receive audible alerts.
- When the measured temperature crosses these thresholds, an audible alarm will sound, and an alert icon may appear on the display.

Abbildung 8.1: The Tzone PTD601 indicating a high or low temperature alarm condition with an audible alert.
9. Wartung
9.1 Reinigung
To clean the device, wipe it with a clean, damp cloth. Do not use abrasive cleaners or immerse the device in water. Ensure the probe is clean before and after each use, especially when measuring different substances.
9.2 Batteriewechsel
When the battery indicator on the LCD screen shows low power, replace the 1.5V AA batteries as described in Section 4.1. Remove batteries if the device will not be used for an extended period to prevent leakage.
9.3 Speicherung
Store the PTD601 in its portable box in a cool, dry place, away from direct sunlight and extreme temperatures. The recommended storage temperature (without battery) is -20℃ to 60℃.
10. Fehlerbehebung
If you encounter issues with your Tzone PTD601, refer to the following common problems and solutions:
- Das Gerät lässt sich nicht einschalten:
- Prüfen Sie den Einbau der Batterie und stellen Sie die korrekte Polarität sicher.
- Replace with fresh 1.5V AA batteries.
- Stellen Sie sicher, dass der Netzschalter ausreichend gedrückt und gehalten wird.
- Ungenaue Temperaturmesswerte:
- Ensure the PT100 probe is securely connected.
- Verify the probe is fully immersed or properly positioned in the measurement area.
- Check for any physical damage to the probe or cable.
- Consider recalibration if accuracy issues persist (refer to calibration certificate or contact support).
- No data report generated via USB:
- Ensure the device is powered on and connected correctly to the computer's USB port.
- Versuchen Sie es mit einem anderen USB-Anschluss oder Kabel.
- Verify that the device's internal memory is not full.
- Restart the computer and reconnect the device.
- Kein Alarm:
- Check the "Sound" setting in the menu to ensure it is enabled.
- Verify that the high and low alarm thresholds are set correctly and that the current temperature is outside these limits.
For issues not covered here, please contact Tzone customer support.
11. Spezifikationen

Abbildung 11.1: Detailed specifications and physical dimensions of the Tzone PTD601 data logger and its probe.
| Besonderheit | Spezifikation |
|---|---|
| Modellnummer | PTD601 |
| Sensortyp | PT100 (-200℃~660℃), PT1000 (-50℃~300℃) |
| Standard Sensor Measurement Range | -160℃ to 300℃ (with included probe) |
| Genauigkeit | ±(0.15+0.002*|t|)℃ |
| Temperatureinheiten | ℃ / ℉ / K |
| Auflösung | 0.1 |
| Messrate | 1 Sekunden/Zeit |
| Datenkapazität | 61,440 Gruppen |
| Schutzgrad | IP52 |
| Maße | 183 x 83 x 35 mm |
| Gewicht | 295g (excluding probe) |
| Sondenkabellänge | 1.5 m |
| Stromquelle | 3 * 1.5 V AA-Batterien |
| Betriebstemperatur | -10℃ bis 50℃ |
| Lagertemperatur | -20℃ to 60℃ (without battery) |
| Konnektivität | USB |
| Besondere Merkmale | Alarm, Auto Off, Backlit, Fast Refresh, High Accuracy |
| Zertifizierungen | CE |
12. Anwendungen
The Tzone PTD601 Temperature Data Logger is suitable for a wide range of professional and industrial applications requiring accurate and reliable temperature monitoring.
- Labor: Monitoring chemical reactions, sample storage, and environmental conditions.
- Maschinenbau: HVAC system analysis, process control, and equipment performance testing.
- Industrial Production: Quality control, environmental monitoring in manufacturing processes.
- Freezer/Cold Chain: Ensuring proper temperature for perishable goods storage and transportation.
- Forschung & Entwicklung: Data collection for experimental setups.

Abbildung 12.1: Examples of the Tzone PTD601 in use across various applications, including industrial settings, laboratories, and freezers.
13. Garantie und Support
13.1 Garantieinformationen
Tzone products are manufactured to high-quality standards. For specific warranty details, please refer to the warranty card included with your product or visit the official Tzone webDie Garantie deckt in der Regel Material- und Verarbeitungsfehler bei normalem Gebrauch ab.
13.2 Kundendienst
If you require technical assistance, have questions about your product, or need to report a defect, please contact Tzone customer support.
- WebWebsite: Visit the official Tzone webWebseite mit häufig gestellten Fragen, Support-Ressourcen und Kontaktinformationen.
- E-Mail/Telefon: Refer to the contact details provided in your product packaging or on the Tzone webWebsite.