1. Einleitung
This manual provides essential information for the safe and effective operation, installation, and maintenance of your TOPWAY 110V AC Gasoline Fuel Pump. This self-priming oil transfer pump is designed for transferring gasoline, fuel, light oils, diesel, and kerosene. Please read this manual thoroughly before use to ensure proper function and to prevent injury or damage.
2. Sicherheitshinweise
Ihre Sicherheit und die Sicherheit anderer haben oberste Priorität. Beachten Sie stets die folgenden Sicherheitsvorkehrungen:
- Lies alle Anweisungen: Before operating the pump, read and understand all instructions and warnings in this manual.
- Entflammbare Flüssigkeiten: This pump is designed for flammable liquids. Always operate in a well-ventilated area, away from ignition sources, open flames, sparks, or excessive heat.
- Rauchen verboten: Do not smoke while operating or near the pump.
- Erdung: Ensure the pump and all associated equipment are properly grounded to prevent static electricity discharge, which can ignite flammable vapors.
- Überhitzungsschutz: The pump is equipped with overheat protection. If the pump overheats, it will automatically shut off. Allow it to cool down before resuming operation.
- Explosion-Proof Design: The pump incorporates explosion-proof components and technology. However, always exercise extreme caution when handling flammable materials.
- Persönliche Schutzausrüstung (PSA): Wear appropriate PPE, including safety glasses and chemical-resistant gloves, when handling fuels.
- Not for Water: This pump is specifically designed for fuels and light oils. Do not use it to pump water or corrosive liquids, as this can damage the pump and void the warranty.
- Elektrische Sicherheit: Stellen Sie sicher, dass die Stromversorgung dem Volumen der Pumpe entspricht.tage (110V AC). Do not operate with damaged cords or plugs.
3. Packungsinhalt
Carefully unpack the box and ensure all items are present and undamaged. If any items are missing or damaged, contact TOPWAY customer support.
- 1 x TOPWAY 110V AC Gasoline Fuel Transfer Pump
- 2 x Hose Adaptors
- 2 x Clips
- 1 x Plastic Oil Filter
- 1 x Dichtungsband

Image 1: The TOPWAY 110V AC Gasoline Fuel Pump shown with its included accessories: hose adaptors, clips, plastic oil filter, and sealing tape.
4. Produktmerkmale
The TOPWAY 110V AC Gasoline Fuel Pump is engineered with several features for reliable and safe fuel transfer:
- Starke Leistung: Capable of transferring fuel at a rate of up to 10 Gallons Per Minute (GPM).
- Selbstansaugend: Designed to self-prime, simplifying the setup process. Maximum suction lift is 6.5 ft.
- Überhitzungsschutz: Built-in thermal protection prevents the motor from overheating during extended operation.
- Explosion-Proof: Features professional explosion-proof components and technology for enhanced safety when handling flammable liquids.
- Langlebige Konstruktion: Made from premium Cast Iron and Stainless Steel (SS) material, ensuring sturdiness and corrosion resistance.
- Motor aus reinem Kupfer: Equipped with a high-efficiency, low-noise pure copper motor for long-lasting performance.
- Tragbares Design: Includes a solid built-in handle for easy carrying and transport.
- Stabile Basis: Features a stable built-in base for direct fixation to various surfaces.
- Built-in Bypass: Allows for continuous operation without damaging the pump if the nozzle is closed.

Abbildung 2: Detailansicht view highlighting key design elements such as the thick metal handle, 100% copper motor, explosion-proof switch, and robust cast iron body, along with a visual representation of included accessories.

Image 3: Illustration demonstrating the self-priming capability of the pump, indicating maximum lift of 33ft and maximum suction of 6.5ft. Also shows icons for compatible liquids: gasoline, fuel, vegetable oil, and kerosene.
5. Spezifikationen
| Spezifikation | Wert |
|---|---|
| Modellnummer | TOP07071-1 |
| Stromquelle | Kabelgebundener Elektrisch (110 V AC) |
| Leistung | 1 / 4 HP |
| Maximaler Durchfluss | 10 Gallonen pro Minute (GPM) |
| Maximale Saughöhe | 6.5 Fuß |
| Maximaler Auftrieb | 33 Fuß |
| Einlass- / Auslassanschluss | NPT 3/4" |
| Hose Adaptor Diameter | Φ19 mm |
| Kompatible Flüssigkeiten | Gasoline, Diesel, Light Oil, Kerosene (Not for water) |
| Material | Gusseisen, Edelstahl |
| Artikelgewicht | 10 Pfund |
| Länge des Netzkabels | 11 Fuß |

Image 4: A visual representation of the pump's specifications, including physical dimensions (7.6 inches length, 5.2 inches height), power cord length, and performance metrics like power, voltage, max flow, max lift, and max suction.
6. Einrichtung
Follow these steps for initial setup of your fuel pump:
- Auspacken: Entnehmen Sie sämtliche Bauteile aus der Verpackung.
- Überprüfen: Check the pump and all accessories for any signs of damage. Do not use if damaged.
- Attach Hose Adaptors: Securely attach the two hose adaptors to the inlet and outlet ports of the pump. Use the provided sealing tape on the threads to ensure a leak-proof connection.
- Filter installieren: Connect the plastic oil filter to the inlet hose adaptor. This filter helps prevent debris from entering the pump.
- Secure Hoses: Attach your fuel hoses (not included) to the hose adaptors using the provided clips to ensure a tight and secure connection.
- Platzierung: Place the pump on a stable, level surface. The built-in base allows for direct fixation if desired. Ensure the pump is positioned in a well-ventilated area, away from any ignition sources.
- Stromanschluss: Connect the pump's power cord to a grounded 110V AC electrical outlet. Ensure the outlet is suitable for outdoor use if operating outdoors.
7. Bedienungsanleitung
Once set up, follow these steps to operate your TOPWAY fuel pump:
- Bereiten: Ensure the inlet hose is fully submerged in the fuel source and the outlet hose is directed into the receiving container.
- Einschalten: Flip the explosion-proof switch to the 'ON' position. The pump will begin to operate.
- Fluss überwachen: The pump is self-priming. Allow a few moments for the pump to prime and begin transferring fuel. Monitor the flow rate and ensure there are no leaks.
- Transfer Fuel: Continue pumping until the desired amount of fuel has been transferred or the source tank is empty.
- Ausschalten: Once transfer is complete, flip the switch to the 'OFF' position.
- Trennen: Carefully disconnect the hoses, ensuring any residual fuel is contained.
Kompatible Flüssigkeiten
This pump is compatible with:
- Benzin
- Diesel
- Light Oils
- Kerosin
WICHTIG: Do not use this pump for water, corrosive chemicals, or highly viscous liquids. Using incompatible liquids can damage the pump and pose safety risks.
8. Wartung
Regelmäßige Wartung gewährleistet die Langlebigkeit und optimale Leistung Ihrer Pumpe:
- Reinigung: After each use, especially when transferring different types of fuel, flush the pump with a small amount of the new fuel or a compatible cleaning agent to prevent contamination and residue buildup. Wipe down the exterior with a clean cloth.
- Filterprüfung: Regularly inspect the plastic oil filter for clogs or damage. Clean or replace the filter as needed to maintain optimal flow and protect the pump.
- Schlauch- und Anschlussprüfung: Periodically inspect hoses, adaptors, and clips for wear, cracks, or leaks. Replace any damaged components immediately.
- Lagerung: When not in use, store the pump in a clean, dry, and well-ventilated area, away from direct sunlight, extreme temperatures, and ignition sources. Ensure all fuel is drained from the pump and hoses before storage.
- Stromkabel: Check the power cord and plug for any damage before each use. Do not use if frayed or damaged.
9. Fehlerbehebung
If you encounter issues with your pump, refer to the following table for common problems and solutions:
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Pumpe startet nicht | Keine Stromversorgung Beschädigtes Netzkabel/Stecker Überhitzungsschutz aktiviert | Stromanschluss und Steckdose prüfen Inspect cord/plug; replace if damaged Allow pump to cool down (approx. 30 mins) |
| Low flow rate or no flow | Verstopfter Filter Air leak in inlet hose/connections Inlet hose not fully submerged Pump not primed (though self-priming, can happen) Excessive lift/suction height | Filter reinigen oder ersetzen Überprüfen Sie alle Verbindungen auf festen Sitz Ensure inlet hose is fully in liquid Ensure sufficient liquid in source tank Reduce lift/suction height within specifications |
| Pumpe ist laut | Luft im System Pumpe läuft trocken Schmutz in der Pumpe | Check for air leaks in inlet line Ensure continuous fuel supply Disconnect power, inspect and clear debris (if safe) |
| Kraftstoffleckage | Lose Verbindungen Damaged hoses/seals | Tighten all hose adaptors and clips Inspect and replace damaged hoses or seals |
If the problem persists after attempting these solutions, please contact TOPWAY customer support.
10. Anwendungen
The TOPWAY 110V AC Gasoline Fuel Pump is versatile and suitable for a wide range of fuel transfer applications, including but not limited to:
- Vehicles (cars, trucks, motorcycles)
- Wohnwagen und Wohnmobile
- Boats and marine vessels
- Agricultural machinery (tractors, harvesters)
- Baumaschinen
- Filling or emptying diesel/oil/gasoline storage tanks

Abbildung 5: Beispielamples of wide applications for the fuel pump, including recreational vehicles (RVs), agricultural harvesters, Jeeps, and transferring fuel from oil barrels.
11. Garantie und Support
Garantie: This TOPWAY fuel pump comes with a 1-year manufacturer's warranty from the date of purchase. This warranty covers defects in materials and workmanship under normal use. It does not cover damage resulting from misuse, abuse, neglect, accident, unauthorized repair, or use with incompatible liquids.
Kundendienst: For any questions, technical assistance, warranty claims, or troubleshooting beyond what is covered in this manual, please contact TOPWAY customer support. Refer to your purchase documentation or the seller's information for specific contact details. Please have your model number (TOP07071-1) and purchase date ready when contacting support.