1. Einleitung
The DIGITEN THT1032 is a versatile temperature and humidity controller designed for precise environmental management. It features three independent outlets for controlling heating/cooling, humidification/dehumidification, and timed operations. Equipped with dual high-precision probes, this device is suitable for various applications including reptile enclosures, mushroom cultivation, plant seeding, and home brewing.
2. Hauptmerkmale
- Plug-and-Play-Betrieb: Simple setup with intuitive buttons for quick configuration.
- Dual High-Precision Probes: Separate probes for temperature (accuracy: ±0.4°C/±0.7°F) and humidity (accuracy: ±3%).
- Triple-Zone Precision Control: Three independent outlets for temperature, humidity, and timed devices.
- Großes LCD-Display: Clear, real-time monitoring with switchable Fahrenheit/Celsius units.
- Climate Customization: Combine heating/cooling with humidification/dehumidification, and program the third outlet for timers.
3. Packungsinhalt
- DIGITEN THT1032 Controller Unit
- Temperaturfühler
- Feuchtigkeitssonde
- Bedienungsanleitung
4. Produktüberschreitungview
The DIGITEN THT1032 controller features a main unit with a large LCD display, control buttons, three power outlets, and two external probes for temperature and humidity sensing.

Bild 1: Vorderseite view of the DIGITEN THT1032 controller, showing the display, buttons, and three power outlets.
4.1. Bedienfeld und Anzeige
The front panel includes an LCD screen and four control buttons: SET, MODE, Up (▲), and Down (▼).

Abbildung 2: Detailansicht view of the controller's outlets and control buttons. OUT1 is for temperature, OUT2 for humidity, and OUT3 for timer functions.
- Set-Taste: Used to select an outlet for configuration or confirm settings.
- MODE-Taste: Used to change the operating mode (e.g., heating/cooling, humidification/dehumidification, timer program).
- Aufwärtstaste (▲): Erhöht Werte oder navigiert durch Menüoptionen.
- Abwärtstaste (▼): Verringert Werte oder navigiert durch Menüoptionen.
- AUS1: Temperature controlled outlet.
- AUS2: Humidity controlled outlet.
- AUS3: Timer controlled outlet.
4.2. Sonden
The controller comes with two separate probes: one for temperature and one for humidity. These probes are essential for accurate environmental monitoring.

Image 3: The temperature probe (left) and humidity probe (right) connected to the controller, illustrating their distinct functions.
5. Ersteinrichtung
- Sonden anschließen: Plug the temperature probe and humidity probe into their respective ports on the controller. Ensure they are securely connected.
- Platzierung: Position the probes in the environment you wish to monitor and control. Ensure they are not directly exposed to heat sources, moisture, or airflow that could skew readings.
- Einschalten: Plug the controller into a standard 120V AC power outlet. The display will illuminate, showing current temperature, humidity, and time.
- Geräte verbinden: Plug your heating/cooling device into OUT1, your humidification/dehumidification device into OUT2, and any timed appliance (e.g., lights, misters) into OUT3.
6. Bedienungsanleitung
6.1. Setting Temperature Control (OUT1)
- Drücken Sie die SATZ button repeatedly until OUT1 is selected (indicated by a flashing OUT1 icon or similar).
- Verwenden Sie die Nach oben (▲) or Runter (▼) Tasten zur Einstellung der gewünschten Zieltemperatur.
- Drücken MODUS to cycle through heating (HEAT) or cooling (COOL) modes. Select the appropriate mode for your connected device.
- Drücken SATZ to confirm the temperature and mode.
- To set the temperature differential (hysteresis), press and hold SATZ for a few seconds when OUT1 is selected. Use Hoch/Runter to adjust the difference between the set point and when the device turns on/off. Press SATZ zur Bestätigung.
6.2. Setting Humidity Control (OUT2)
- Drücken Sie die SATZ button repeatedly until OUT2 is selected.
- Verwenden Sie die Nach oben (▲) or Runter (▼) buttons to adjust the desired target humidity percentage.
- Drücken MODUS to cycle through humidification (HUMIDIFICATION) or dehumidification (DEHUMIDIFICATION) modes. Select the appropriate mode.
- Drücken SATZ to confirm the humidity and mode.
- To set the humidity differential, press and hold SATZ for a few seconds when OUT2 is selected. Use Hoch/Runter Zum Einstellen drücken. SATZ zur Bestätigung.
6.3. Setting Timer Control (OUT3)
- Drücken Sie die SATZ button repeatedly until OUT3 is selected.
- Drücken MODUS to enter the timer programming interface.
- Verwenden Nach oben (▲) or Runter (▼) to set the ON time (hour and minute). Press SATZ um zur nächsten Einstellung zu wechseln.
- Stellen Sie die Ausschaltzeit (Stunde und Minute) ein mit Hoch/Runter Und SATZ.
- The controller supports multiple ON/OFF programs for OUT3. Refer to the on-screen prompts for additional program slots.
- Drücken SATZ to save and exit the timer settings.
6.4. Umschalten der Temperatureinheiten (°C/°F)
To switch between Celsius and Fahrenheit, press and hold the Nach oben (▲) button for approximately 3 seconds. The display will change accordingly.
7. Wartung
- Reinigung: Wischen Sie die Steuereinheit mit einem weichen, trockenen Tuch ab. Verwenden Sie keine Scheuermittel und tauchen Sie die Einheit nicht in Wasser.
- Sondenpflege: Keep the probes clean and free from debris. Avoid bending or damaging the probe cables. If probes become dirty, gently clean them with a damp cloth and allow them to dry completely before re-use.
- Lagerung: Bewahren Sie den Controller bei Nichtgebrauch an einem kühlen, trockenen Ort fern von direkter Sonneneinstrahlung und extremen Temperaturen auf.
8. Fehlerbehebung
| Ausgabe | Mögliche Ursache | Lösung |
|---|---|---|
| Das Display ist leer oder lässt sich nicht einschalten. | Keine Stromversorgung; lose Verbindung. | Ensure the controller is securely plugged into a live power outlet. Check the power source. |
| OUT1/OUT2/OUT3 not activating connected device. | Incorrect settings; device malfunction; power issue. | Verify temperature/humidity/timer settings. Check if the connected device is working independently. Ensure the controller's set point is met for activation. |
| Humidity probe shows "ERR" reading. | Probe malfunction; damaged cable; sensor error. | Check the humidity probe connection. Inspect the probe cable for damage. If the error persists, the probe may need replacement. |
| Ungenaue Temperatur-/Feuchtigkeitsmesswerte. | Probe placement; dirty probe; probe malfunction. | Relocate probes away from direct heat/moisture/airflow. Clean probes gently. If issues persist, consider probe replacement. |
9. Technische Daten
| Spezifikation | Wert |
|---|---|
| Modellnummer | THT1032 |
| Strombedarf | 100-240 V Wechselspannung |
| Tragfähigkeit | 10A per outlet (1100W@110V, 2200W@220V) |
| Temperaturregelbereich | -10 °C bis 120 °C / 14 °F bis 248 °F |
| Temperaturgenauigkeit | ± 0.4 ° C / ± 0.7 ° F |
| Feuchtigkeitsgenauigkeit | ±3 % |
| Sondensensortyp | Digital Signal Output, I2C Interface |
| Betriebsumgebungstemperatur | 0–50 °C |
| Operating Environment Relative Humidity | <85 % |
| Anzeigetyp | LCD |
| Material | Plastik |
| Farbe | Grau |
| Artikelgewicht | 1.04 Pfund |
| Verpackungsabmessungen | 6.85 x 6.34 x 1.93 Zoll |
10. Garantie und Kundendienst
DIGITEN provides a one-year warranty for any quality-related issues with this product. For technical assistance, troubleshooting, or warranty claims, please contact DIGITEN customer support through the retailer where the product was purchased or visit the official DIGITEN webWebsite für Kontaktinformationen.
Bitte bewahren Sie Ihren Kaufbeleg für Garantieleistungen auf.