1. Einleitung
Thank you for choosing the Vente-unique TYRA Hydromassage Shower Column. This manual provides essential information for the safe installation, operation, and maintenance of your new shower system. Please read these instructions carefully before installation and retain them for future reference.
2. Sicherheitshinweise
- Ensure all plumbing connections are secure to prevent leaks.
- Verify water pressure is within recommended limits for optimal performance and to avoid damage.
- Always test water temperature before use to prevent scalding.
- Die Installation sollte von einem qualifizierten Fachmann durchgeführt werden, wenn Sie sich bei einzelnen Schritten unsicher sind.
- Do not use abrasive cleaners or harsh chemicals on the shower column's surface.
3. Packungsinhalt
Bitte prüfen Sie vor Beginn der Installation, ob alle Komponenten vorhanden sind:
- TYRA Hydromassage Shower Column
- Handbrause mit Schlauch
- Montagehalterungen und Hardware
- Installationsanleitung (dieses Dokument)
- Sealing washers and gaskets
4. Spezifikationen
| Besonderheit | Detail |
|---|---|
| Marke | Einzelverkauf |
| Modell | TYRA |
| Abmessungen (L x B x H) | 20 x 44 x 150 cm |
| Gewicht | 6.5 Kilogramm |
| Farbe | Schwarz |
| Merkmale | Hydromassage jets, Rain shower, Hand shower |
Note: All dimensions are approximate and subject to minor manufacturing variations.
5. Einrichtung und Installation
Before installation, ensure you have the necessary tools (drill, level, wrench, sealant) and that your water supply lines are accessible and compatible.
- Bereiten Sie die Wand vor: Mark the desired mounting height for the shower column. Ensure the wall is structurally sound and capable of supporting the unit's weight.
- Montagehalterungen: Using the provided template or measurements, drill holes for the mounting brackets. Secure the brackets firmly to the wall with appropriate fasteners.
- Wasserleitungen anschließen: Connect the hot and cold water supply lines to the corresponding inlets on the back of the shower column. Use sealing washers and ensure all connections are watertight.
- Hang the Column: Carefully hang the shower column onto the mounted brackets. Ensure it is level and securely seated.
- Endgültige Verbindungen: Connect the hand shower hose to its outlet on the column.
- Auf Dichtheit prüfen: Turn on the water supply and check all connections for leaks. Operate each function of the shower column to ensure proper water flow and temperature.


6. Bedienungsanleitung
The TYRA shower column offers multiple functions for a personalized showering experience.
- Wasserflusskontrolle: Use the main knob/lever to turn the water on/off and adjust the flow intensity.
- Temperaturkontrolle: The temperature knob allows you to set your desired water temperature. Always check the temperature before stepping into the shower.
- Funktionsauswahl: Rotate the selector knob to switch between the different shower functions:
- Regenschauer: Water flows from the overhead showerhead for a wide, gentle spray.
- Hydromassagedüsen: Water sprays from the body jets for a targeted massage.
- Hand dusche: Detach the hand shower for flexible, directed rinsing.

7. Wartung
Regular cleaning and maintenance will ensure the longevity and optimal performance of your shower column.
- Reinigung der Oberfläche: Wipe the column regularly with a soft cloth and mild soap or a non-abrasive bathroom cleaner. Rinse thoroughly and dry to prevent water spots.
- Düsenreinigung: The silicone nozzles on the showerhead and body jets are designed for easy cleaning. Gently rub them with your finger or a soft brush to dislodge any mineral deposits.
- Entkalkung: In areas with hard water, descaling may be necessary. Use a descaling solution specifically designed for bathroom fixtures, following the product's instructions. Avoid strong acids or abrasive materials.
- Schlauchwartung: Periodically check the hand shower hose for kinks or damage. Clean the hose with a soft cloth.
8. Fehlerbehebung
| Problem | Mögliche Ursache | Lösung |
|---|---|---|
| Niedriger Wasserdruck | Clogged nozzles, low household water pressure, partially closed shut-off valve | Clean nozzles, check household water pressure, ensure shut-off valves are fully open. |
| Lecks aus Verbindungen | Loose connections, worn washers | Tighten connections, replace washers if necessary. Apply plumber's tape if needed. |
| Wasser nicht heiß genug | Water heater setting too low, insufficient hot water supply, faulty thermostatic cartridge | Adjust water heater temperature, ensure adequate hot water supply, contact a professional if cartridge is suspected. |
| Tropfen nach Gebrauch | Residual water in showerhead, worn cartridge | Normal for a short period due to residual water. If persistent, a cartridge replacement might be needed by a professional. |
If you encounter problems not listed here or if solutions do not resolve the issue, please contact Vente-unique customer support.
9. Garantie und Support
Your Vente-unique TYRA Hydromassage Shower Column is covered by legal guarantees and a 30-day return policy, as provided by VENTE-UNIQUE. For any questions, technical assistance, or warranty claims, please contact Vente-unique Specialized Customer Support.
Weitere Informationen finden Sie im Vente-unique Brand Store.