Elitech PG-30

Elitech PG-30Pro Digitales Manometer – Benutzerhandbuch

Model: PG-30 | Brand: Elitech

1. Einleitung

This manual provides detailed instructions for the proper use and maintenance of the Elitech PG-30Pro Digital Pressure Gauge. This device is designed for accurate pressure measurement in refrigeration and HVAC systems. Please read this manual thoroughly before operation to ensure correct usage and to prevent damage.

Elitech PG-30Pro Digital Pressure Gauge

Figure 1: Elitech PG-30Pro Digital Pressure Gauge. This image displays the front view of the digital pressure gauge, featuring a blue face with a clear LCD screen, power button, 'SET' button, and 'ZERO' button. The 1/8'' NPT connection is visible at the bottom.

2. Produktmerkmale

Elitech PG-30Pro Features Overview

Abbildung 2: Überview of Elitech PG-30Pro features. This graphic highlights key functionalities such as backlight display, Max/Min value, zeroing, refrigerant support, auto shut-off, and adjustable units.

Elitech PG-30Pro Refrigerant Compatibility

Figure 3: Refrigerant compatibility of the Elitech PG-30Pro. This image illustrates the gauge's ability to work with over 90 types of refrigerants, including R12, R22, R134a, R290, R401A, R403A, R740, R744, R601, R143A, R32, R21, and R1234yf.

3. Einrichtung

3.1 Einlegen der Batterie

  1. Suchen Sie die Abdeckung des Batteriefachs auf der Rückseite des Geräts.
  2. Remove the cover by twisting or sliding it according to the markings.
  3. Legen Sie zwei (2) AAA-Batterien ein und achten Sie dabei auf die richtige Polarität (+/-), wie im Batteriefach angegeben.
  4. Bringen Sie den Batteriefachdeckel wieder fest an.

3.2 Erstverbindung

  1. Ensure the system to which the gauge will be connected is depressurized or isolated.
  2. Carefully thread the 1/8'' NPT fitting of the digital pressure gauge onto the appropriate port of your HVAC or refrigeration system.
  3. Tighten the connection firmly by hand, then use a wrench for a final snug turn to prevent leaks. Do not overtighten.
Elitech PG-30Pro 1/8-inch NPT Fitting

Figure 4: Dimensions and 1/8-inch NPT fitting. This image shows the physical dimensions of the gauge and highlights the 1/8-inch NPT threaded connection for system integration.

4. Bedienungsanleitung

4.1 Ein-/Ausschalten

4.2 Nullfunktion

The zero function is used to correct any minor deviations at the zero pressure point before taking a measurement.

Elitech PG-30Pro Zeroing Function

Figure 5: Zeroing function button. This image highlights the 'ZERO' button on the gauge, indicating its use for resetting the pressure reading to zero.

4.3 Changing Units (Pressure/Temperature)

To cycle through available pressure and temperature units:

Elitech PG-30Pro Adjustable Units

Figure 6: Adjustable temperature and pressure units. This graphic illustrates the various units available for both temperature (°C / °F) and pressure (psi, kg/cm², cmHg, bar, kPa, Mpa, kg/cm²).

4.4 Selecting Refrigerants

The gauge has a built-in database of refrigerants for PT comparison.

4.5 Messwerte ablesen

Once connected and powered on, the gauge will display the current pressure and corresponding saturation temperature for the selected refrigerant on its LCD screen.

4.6 Max/Min Value Display and Reset

Zu view the recorded maximum and minimum pressure values:

Elitech PG-30Pro Max/Min Value Display and Reset

Figure 7: Max/Min value display and reset. This image illustrates how the power button is used to cycle through readings and the zero button to reset recorded maximum and minimum values.

4.7 Einstellung für automatische Abschaltung

The gauge features an adjustable auto shut-off time to conserve battery life.

Elitech PG-30Pro Auto Shut-Off Setting

Figure 8: Auto shut-off setting. This image highlights the 'SET' button, used for configuring the automatic power-off duration to save battery life.

5. Wartung

5.1 Reinigung

5.2 Batteriewechsel

5.3 Speicherung

6. Fehlerbehebung

ProblemMögliche UrsacheLösung
Das Messgerät lässt sich nicht einschalten.Leere oder falsch eingelegte BatterienBatterien austauschen und dabei auf die richtige Polarität achten.
Ungenaue DruckmessungGauge not zeroed; Sensor contamination; Incorrect unit selectedPerform zero function; Clean sensor port if accessible; Verify selected pressure unit.
Display shows 'ALARM' or flashesPressure overloadImmediately disconnect from pressure source. The gauge is operating beyond its specified range.
Hintergrundbeleuchtung funktioniert nichtLow battery; Backlight setting offReplace batteries; Check if backlight can be toggled (refer to operating instructions).

7. Spezifikationen

SpezifikationDetail
ModellnummerPG-30
Druckbereich-14.5 bis 500 PSI
Verbindungstyp1/8'' NPT
Temperaturdrift±0.04%FS/℃
Kältemittelunterstützung87 types built-in
Stromquelle2 x AAA-Batterien
MaterialPlastik
Produktabmessungen (L x B x H)6.3 x 4.72 x 8.27 Zoll
Artikelgewicht8.89 Unzen

8. Garantie und Support

8.1 Garantieinformationen

The Elitech PG-30Pro Digital Pressure Gauge comes with a 12 Monate Garantie from the date of purchase, covering manufacturing defects and malfunctions under normal use. This warranty does not cover damage caused by misuse, accident, unauthorized modification, or improper installation.

8.2 Technischer Support

For technical assistance, troubleshooting, or warranty claims, please contact Elitech customer support. 24/7 US Technician Support is available via email and phone.

Zugehörige Dokumente - PG-30

Vorview Elitech MS-100 Digitales Manometer Benutzerhandbuch
Benutzerhandbuch für das digitale Manifold-Messgerät Elitech MS-100 mit detaillierten Informationen zu Funktionen, Betrieb, Spezifikationen und Wartung.
Vorview Elitech MS-100 Digitales Manometer: Funktionen, Bedienung und Spezifikationen
Ausführlicher Leitfaden zum digitalen Manometer Elitech MS-100 mit Informationen zu Funktionen, schneller Bedienung, technischen Spezifikationen, Vorsichtsmaßnahmen und Produktdetails für HLK- und Kälteanlagen.
Vorview Elitech MS-Serie Digitales Manometer – Benutzerhandbuch
Benutzerhandbuch für das digitale Manometer der Elitech MS-Serie, einschließlich Produktbeschreibung, allgemeiner ÜbersichtviewTastenfunktionen, Spezifikationen, Kurzanleitung, Bedienungsschritte, intelligente Anwendungen und Wartung.
Vorview Elitech MS-100 PLUS Smart Digital Manometer – Benutzerhandbuch
Ausführliches Benutzerhandbuch für das Elitech MS-100 PLUS Smart Digital Manometer, einschließlich Produkteinführung, Sicherheitshinweise und mehr.view, Tastenfunktionen, technische Parameter und Kurzanleitungen für Kälte- und Klimatechniksysteme.
Vorview Elitech MS-800 Serie Digitales Manometer – Benutzerhandbuch & Spezifikationen
Ausführliches Benutzerhandbuch für das digitale Manometer der Elitech MS-800 Serie, mit Produkteinführung, Sicherheitsrichtlinien, Umweltschutz, detaillierten Spezifikationen und Kurzanleitungen für Druck- und Temperaturmessungen, Haltedruckprüfungen und Kältemittelbefüllung für HLK- und Kälteanlagen.
Vorview Elitech DMG-2SE Digital Manifold Gauge User Manual
User manual for the Elitech DMG-2SE Digital Manifold Gauge. Features include a built-in database of 88 refrigerants that automatically calculates saturation temperature. This guide details operation, technical specifications, safety, and maintenance for HVAC applications, ensuring efficient and accurate measurements.