1. Einleitung

The Tzone TempU02 is a single-use USB temperature data logger designed for reliable temperature monitoring during cold chain transportation, food storage, and other temperature-sensitive applications. It generates an automatic PDF report without requiring special software, simplifying data retrieval.

Zu den Hauptmerkmalen gehören:

Tzone TempU02 USB Temperature Data Logger

Figure 1: Tzone TempU02 USB Temperature Data Logger.

2. Einrichtung und Aktivierung

To begin temperature recording, activate the device as follows:

  1. Locate the "PRESS START STOP" button on the front of the logger.
  2. Press and hold the button for approximately 5 seconds until the "OK" LED indicator flashes, confirming activation.
  3. The device will initiate a 30-minute start-up protection delay before beginning actual temperature recording. This delay helps improve measurement accuracy by allowing the device to stabilize in its environment.
Tzone TempU02 Data Logger with labeled parts and start button

Figure 2: Device components and activation button. The device ID is TZ2024101960.

3. Operation and Status Indicators

The TempU02 data logger provides visual feedback through its LED indicators:

Regularly check these indicators to monitor the temperature status of your goods during transit or storage.

4. Data Retrieval and Report Generation

The TempU02 simplifies data retrieval by generating a PDF report directly:

  1. Once the monitoring period is complete, connect the USB port of the data logger directly to a computer.
  2. The device will automatically generate a PDF report containing all recorded temperature data. No special software installation is required.
  3. Wichtiger Hinweis: Once the logger is plugged into a USB port, it will stop recording and cannot be reactivated for further use. This device is designed for single-use applications.
Tzone TempU02 Data Logger connected to a laptop, showing PDF report generation

Figure 3: The data logger connected to a laptop, illustrating the automatic PDF report generation. The device ID is TZ2024101960.

Tzone TempU02 Data Logger in a cold chain transportation scenario

Figure 4: The compact data logger being used in a cold chain environment. The device ID is TZ2024101960.

5. Wartung und Pflege

The TempU02 data logger is designed for durability and ease of use:

Tzone TempU02 Data Logger demonstrating IP67 waterproof feature

Figure 5: The data logger submerged in water, illustrating its IP67 waterproof capability when sealed.

6. Fehlerbehebung

7. Spezifikationen

BesonderheitDetail
ModellTempU02
Messbereich-30 °C bis 70 °C (-22 °F bis 158 °F)
Genauigkeit±0.5°C (-20°C to 40°C); ±1°C (others)
Temperature Alarm ThresholdsLow: <2°C (35.6°F), High: >8°C (46.4°F)
Datenspeicherkapazität17281 Datensätze
Protokollintervall5 Мinuten
Startverzögerung30 Мinuten
AufnahmedauerBis zu 60 Tage
KonnektivitätUSB 2.0
WasserdichtigkeitIP67 (with intact packaging)
ZertifizierungenEN12830, CE, RoHS, FDA
Batterie1 CR2032 (im Lieferumfang enthalten)
MaßeUngefähr 3.15 x 1.57 x 0.39 Zoll
GewichtUngefähr 0.35 Unzen
Tzone TempU02 Data Logger with detailed specifications

Figure 6: Visual representation of the TempU02 data logger with its key specifications. The device ID is TZ2024101960.

8. Garantie und Support

Each Tzone TempU02 data logger comes with a calibration certificate, ensuring its accuracy and compliance with industry standards.

For any technical assistance, questions, or support regarding the Tzone TempU02 data logger, please refer to the contact information provided with your purchase or visit the official Tzone webWebsite.

9. Wichtige Hinweise

Zugehörige Dokumente - TempU02

Vorview Benutzerhandbuch und Datenblatt für Temperaturdatenlogger der Serie TempU06
Benutzerhandbuch und technisches Datenblatt für die Temperaturdatenlogger der Serie Tzone TempU06. Enthält Produktvorstellung, Funktionen, Gebrauchsanweisungen, Konfiguration, Batterieinformationen, Sicherheitshinweise und detaillierte Spezifikationen für die Modelle TempU06, TempU06 L100 und TempU06 L200.
Vorview Benutzerhandbuch für den Temperaturdatenlogger der Tzone TempU06-Serie
Benutzerhandbuch für die Temperaturdatenlogger der Tzone TempU06-Serie. Enthält Produktvorstellung, Funktionen, Bedienungsanleitung, Konfiguration, Batteriewechsel und technische Daten. Umfasst die Modelle TempU06, TempU06 L100 und TempU06 L200.
Vorview Benutzerhandbuch für den Temperaturdatenlogger der Tzone TempU06-Serie
Benutzerhandbuch für die Temperaturdatenlogger der Tzone TempU06-Serie mit detaillierten Funktionen, Betrieb, Konfiguration und technischen Spezifikationen zur Überwachung der Temperatur bei Lagerung und Transport empfindlicher Güter wie Impfstoffe, Arzneimittel und Lebensmittel.
Vorview TT19/TT19EX – Kurzanleitung zur Einrichtung
Eine umfassende Anleitung zum Einrichten und Verwenden des Echtzeit-Datenloggers TT19/TT19EX, einschließlich Geräteregistrierung, Einlegen der SIM-Karte, Anschließen der Batterie und Abfragen der Daten.
Vorview TZ-Tag08 LoRa-Temperatursensor – Benutzerhandbuch | TZONE Digital Technology
Ausführliches Benutzerhandbuch für TZONE TZ-Tag08 LoRa-Temperatursensor. Erfahren Sie mehr über Funktionen, Anwendungen, Spezifikationen, Betriebsmodi und Installation. Enthält FCC- und ISED-Erklärungen.
Vorview WF501/WF502 Quick Setup Guide - TZONE Data Loggers
Concise setup guide for TZONE WF501 and WF502 data loggers. Learn how to download software, configure WiFi, connect devices, and query data via the TZONE cloud platform.