1. Einleitung
Thank you for choosing the Sainlogic SA6 Wireless Weather Station. This professional-grade device provides comprehensive indoor and outdoor weather monitoring, including temperature, humidity, barometric pressure, wind speed and direction, rainfall, and moon phase. Its 6.5-inch HD color LCD screen offers excellent readability with adjustable backlight. This manual will guide you through the setup, operation, and maintenance of your weather station to ensure optimal performance.
2. Lieferumfang
- Konsole anzeigen
- Integrierter Außensensor
- Netzteil
- Bedienungsanleitung
- Fußmontage (mit Stangeneinsatz)
- Montagehalterung Rückplatte (für Mastmontage)
- Montagestange
- 2x Befestigungsmuttern (M3) / Schrauben (03) für Masten
- 4x Befestigungsmuttern (M5) / Schrauben (05) für Masten
- 4x Blechschrauben
3. Einrichtung
3.1. Installation des Außensensors
The outdoor sensor is designed for easy installation and provides accurate data. Ensure the sensor is placed in an open area, away from obstructions like buildings, trees, or high voltage lines, to ensure reliable data transmission.
Einlegen der Batterie
The outdoor sensor requires 3 AA batteries (not included). Use the provided screwdriver to open the battery compartment, insert the batteries, and securely close the compartment. The rubber gasket ensures water resistance.
Vorsichtsmaßnahmen bei der Montage
When installing the outdoor sensor, ensure the 'S' sign on the unit is aimed correctly:
- If located in the northern hemisphere, aim the 'S' sign at the South.
- If located in the southern hemisphere, aim the 'S' sign at the North.
This ensures accurate wind direction readings.
Montageoptionen
The outdoor sensor offers various mounting options to suit your location:


For a visual guide on installation, please refer to the setup video below:
This video demonstrates the setup process for the Sainlogic SA6 Weather Station, including outdoor sensor pairing, installation precautions, and detailed instructions for adjusting settings such as snooze mode, time, date, measurement units, and calibration.
3.2. Einrichtung der Anzeigekonsole
Connect the provided power adapter to the display console and plug it into a power outlet. For backup power during outages, you can install 3 AAA batteries (not included) into the battery compartment on the back of the console.
3.3. Pairing Outdoor Sensor with Display Console
To establish communication between the outdoor sensor and the display console:
- Drücken Sie auf der Anzeigekonsole lange die Taste TEMP button for 3 seconds. The display will clear, and a search icon will begin to flash, indicating it's searching for the outdoor sensor.
- On the outdoor sensor, locate the ZURÜCKSETZEN button (usually near the battery compartment) and press it. An LED light on the sensor will blink.
- The console and sensor will begin pairing. Once successfully paired, the search icon on the display will stop flashing, and weather data will appear.
Refer to the setup video above for a visual demonstration of the pairing process.
4. Bedienungsanleitung
4.1. Anzeige überview
The 6.5-inch HD color LCD provides a clear, at-a-glance view of all critical weather metrics. The display is organized into several sections:


- Windabschnitt: Wind direction, gust speed, and average wind speed.
- Wettervorhersage: Symbole zur Anzeige der vorhergesagten Wetterbedingungen.
- Luftdruck: Current air pressure readings.
- Mond Phase: Aktuelle Mondphasenanzeige.
- Outdoor Sensor Data: Temperature, humidity, dew point, and 'feels like' temperature.
- Indoor-Daten: Temperatur und Luftfeuchtigkeit.
- Niederschlagsmenge: Hourly, daily, weekly, monthly, and total rainfall measurements.
- Zeit Datum: Aktuelle Uhrzeit und Datum.
4.2. Tastenfunktionen
The control buttons are located at the bottom of the display console:
- EINSTELLEN: Press to switch displayed time (year, month, day, second, week). Long press to enter Set Mode.
- TEMP: Press to switch between dew point, feels like, and temperature. Long press to pair indoor and outdoor units.
- REGEN: Press to switch rainfall display (1h, 24h, week, month, total). In Set Mode, press to increase value. Long press to clear rainfall data.
- WIND / +: In Set Mode, press to increase value.
- PRESSURE / -: Press to switch to display pressure (relative/absolute). In Set Mode, press to reduce value.
- ALARM: In Calibration Mode, press to reset. Press to view high & low alert values. Long press to set alarm information.
- MAX MIN: In Calibration Mode, press to view high & low alert values. Press to view max & min values. Long press to enter Calibration Mode.
- LICHT/SCHLUMMER: Press to switch backlight level. Long press to enter Snooze Mode. In other modes, press to exit.
4.3. Uhrzeit und Datum einstellen
To set the time and date, long press the SATZ button to enter Set Mode. Use the REGEN Und DRUCK buttons to adjust values, and the SATZ button to confirm and move to the next setting. You can set the 12/24 hour format, hour, minute, date format (month/day or day/month), month, day, and year.
4.4. Changing Units of Measurement
In Set Mode, you can also change the units for various measurements:
- Temperatur: Wechseln Sie zwischen °C und °F.
- Luftdruck: Switch between inHg and hPa.
- Niederschlagsmenge: Switch between inch and mm.
- Windgeschwindigkeit: Switch between mph, knots, bft, m/s, and km/h.
4.5. Snooze Mode and Backlight
Drücken Sie die LICHT/SNOOZE button to cycle through different backlight brightness levels. Long press the LICHT/SNOOZE button to activate or deactivate Snooze Mode, which turns off the backlight after a short period.
4.6. Alarme und Warnungen
The weather station supports customizable alerts for various weather conditions. Long press the ALARM button to enter alarm setting mode. You can set high and low alerts for temperature, humidity, and pressure. When an alert condition is met, the display will flash and an audible alarm will sound.

4.7. Max/Min Values
Drücken Sie die MAX/MIN Taste, um view the recorded maximum and minimum values for temperature, humidity, and other metrics. To clear these records, long press the REGEN Taste während viewing the respective data.
For a comprehensive guide on button functions, setting modes, and calibration, please watch the full setup tutorial video:
This video demonstrates the setup process for the Sainlogic SA6 Weather Station, including outdoor sensor pairing, installation precautions, and detailed instructions for adjusting settings such as snooze mode, time, date, measurement units, and calibration.
5. Wartung
5.1. Cleaning the Rain Collector
Regularly check and clean the rain collector funnel to prevent debris (leaves, insects) from obstructing the measurement mechanism. This ensures accurate rainfall readings.
5.2. Batteriewechsel
- Außensensor: Replace the 3 AA batteries approximately every 12 months, or when the low battery indicator appears on the display console.
- Anzeigekonsole: If using backup batteries, replace the 3 AAA batteries when the low battery indicator appears.
6. Fehlerbehebung
6.1. No Display on Console
- Stellen Sie sicher, dass das Netzteil sowohl an die Konsole als auch an eine funktionierende Steckdose fest angeschlossen ist.
- If using backup batteries, check if they are correctly installed and not depleted.
6.2. Outdoor Sensor Not Transmitting Data
- Check the batteries in the outdoor sensor and replace them if necessary.
- Drücken Sie die ZURÜCKSETZEN button on the outdoor sensor.
- Re-initiate the pairing process as described in Section 3.3.
- Ensure the outdoor sensor is within the wireless transmission range and there are no major obstructions.
6.3. Ungenaue Messwerte
- Temperatur/Luftfeuchtigkeit: Ensure the outdoor sensor is not exposed to direct sunlight or heat sources, which can skew readings.
- Niederschlagsmenge: Verify the rain collector is clean and free of debris.
- Windrichtung: Confirm the 'S' sign on the outdoor sensor is correctly oriented (South in Northern Hemisphere, North in Southern Hemisphere).
- Kalibrierung: If readings appear consistently off, refer to the 'Calibration Mode' section in the setup video for instructions on fine-tuning sensor values.
7. Spezifikationen
| Besonderheit | Spezifikation |
|---|---|
| Marke | Sainlogic |
| Modellnummer | SA6 |
| Stil | Professional |
| Farbe | Schwarz |
| Material | Acrylnitril-Butadien-Styrol (ABS) |
| Technische Daten | 1"T x 6.7"B x 5.2"H |
| Artikelgewicht | 2.3 Pfund |
| Stromquelle | Batteriebetrieben (Außensensor), Netzteil (Anzeigekonsole) |
| Anzahl Batterien | 3 AA batteries required (Outdoor Sensor), 3 AAA batteries required (Display Console backup) |
| Konnektivitätstechnologie | Drahtlos (433 MHz) |
| Anzeigetyp | LCD (6.5" HD Color) |
| Temperaturbereich (Innenbereich) | 0°C bis 60°C |
| Temperaturbereich (im Freien) | -40°C bis 60°C |
| Temperaturgenauigkeit | ±1 °C |
| Feuchtigkeitsbereich | 10 % bis 99 % |
| Barometrischer Druckbereich | 300-1100hPa |
| Genauigkeit der Niederschlagsvorhersage | ±1mm for <15mm, ±7% for 15-9999mm |
| Besondere Merkmale | Alarm, Clock, Customizable Alert, Large Display, Wireless |
8. Garantie und Support
Sainlogic is committed to providing quality products and excellent customer service. Your Sainlogic SA6 Weather Station comes with a standard 30-day return service.
Support kontaktieren
Bei Fragen, technischem Support oder Garantieansprüchen wenden Sie sich bitte an unser Kundendienstteam:
- Telefonischer Support: Montag bis Freitag, 10:00 bis 6:00 Uhr (Ostküstenzeit).
- E-Mail-Support: support@sainlogic.com. We guarantee a reply within 24 hours on weekdays and within 48 hours on weekends.
- Offiziell WebWebsite: Besuchen Sie die Sainlogic-Beamter webWebsite for additional guides and support resources.