The KING LPWV2715-CT24 is a robust, vandal-resistant electric heater designed for high-traffic and public areas such as detention facilities, public restrooms, and rest areas. Its heavy-duty construction, including a 3/16-inch solid steel frame and grill, provides exceptional durability against impact and abuse. Tamper-resistant screws secure the grill, and controls are recessed to prevent unauthorized access. This unit offers moderate wattage and high airflow to effectively heat entryways and hallways, preventing drafts from affecting the building's core temperature.

KING LPWV2715-CT24 Vandal Resistant Heater, front view

Bild 1: Vorderseite view of the KING LPWV2715-CT24 Vandal Resistant Heater, showcasing sein robustes Metall casing and grill.

Hauptmerkmale:

  • Impact/Vandal Resistant: Constructed with a heavy grill and 3/16-inch solid steel frame.
  • Pic-A-Watt Elements: Allows for multiple wattage options to suit specific heating requirements.
  • Tamper Resistant 3 Position Switch: Offers Fan, Heat, and Off settings, designed to prevent unauthorized adjustments.
  • Überhitzungsschutz: Integrierte Sicherheitsfunktion zum Schutz vor Überhitzung.

2. Sicherheitshinweise

Read all instructions carefully before installing or using this heater. Failure to follow these instructions may result in electric shock, fire, property damage, or personal injury.

  • Elektroinstallation: This heater operates on 277 Volts and requires hardwiring. Installation must be performed by a qualified electrician in accordance with all national and local electrical codes.
  • Erdung: This heater must be properly grounded to reduce the risk of electric shock.
  • Standort: Do not install the heater in areas where gasoline, paint, or other flammable liquids are stored or used. Maintain proper clearances from combustible materials as specified in the installation section.
  • Überhitzungsschutz: The heater is equipped with a thermal cut-out to prevent overheating. If the heater shuts off due to overheating, allow it to cool down before attempting to restart. Investigate and correct the cause of overheating.
  • Nicht abdecken: Never cover the heater or block its air inlets/outlets. This can cause overheating and fire.
  • Wartung: Vor jeglichen Wartungs- oder Reinigungsarbeiten die Stromzufuhr unterbrechen.

3. Packungsinhalt

Prüfen Sie beim Öffnen der Verpackung, ob alle Komponenten vorhanden und unbeschädigt sind:

  • KING LPWV2715-CT24 Vandal Resistant Heater Unit
  • Montagezubehör (in der Regel enthalten)
  • Bedienungsanleitung (dieses Dokument)

Falls Artikel fehlen oder beschädigt sind, kontaktieren Sie umgehend Ihren Lieferanten.

4. Installation

WARNUNG: Installation must be performed by a qualified electrician. Disconnect all power to the circuit at the main service panel before attempting any wiring.

4.1 Montageort

  • This heater is designed for indoor, wall-mount installation.
  • Choose a location that allows for proper air circulation and maintains required clearances from walls, ceilings, and floors. Refer to local codes for specific clearance requirements.
  • Ensure the mounting surface is structurally sound to support the heater's weight (approximately 36 pounds).

4.2 Elektrischer Anschluss

  • The LPWV2715-CT24 heater requires a dedicated 277 Volt, 60 Hz, single-phase circuit.
  • Die Heizung verbraucht 5.4 Amps at 277V, providing 1500 Watts of heat. Ensure the circuit breaker and wiring are appropriately sized for this load.
  • Connect the heater directly to the electrical supply using appropriate hardwiring methods and connectors, following the wiring diagram provided inside the heater's access panel.
  • Stellen Sie sicher, dass alle Verbindungen fest und sicher sind.

5. Bedienung

Once properly installed and powered, the heater can be operated using its tamper-resistant 3-position switch.

5.1 Netzschaltereinstellungen

  • AUS: The heater is completely off, and no heat or fan operation will occur.
  • VENTILATOR: The fan operates continuously without engaging the heating elements. This can be used for air circulation.
  • HITZE: The heating elements and fan operate to provide warmth. The heater will cycle on and off to maintain the desired temperature if connected to an external thermostat (not included).

5.2 Wattage Selection (Pic-A-Watt)

The LPWV series heaters feature Pic-A-Watt elements, allowing for field-adjustable wattage settings. Refer to the wiring diagram inside the heater for instructions on how to adjust the wattage to suit specific room requirements. This adjustment should only be performed by a qualified technician with power disconnected.

6. Wartung

Regular maintenance ensures optimal performance and longevity of your heater. Always disconnect power at the circuit breaker before performing any maintenance.

  • Reinigung: Reinigen Sie die Außenseite des Heizgeräts regelmäßig mit einem weichen, fusselfreien Tuch.amp Tuch. Keine Scheuer- oder Lösungsmittel verwenden.
  • Lufteinlässe/Luftauslässe: Ensure that the air inlets and outlets are free from dust, lint, and other obstructions. Use a vacuum cleaner with a brush attachment to gently clean the grill and internal components if accessible.
  • Inspektion: Annually inspect the heater for any signs of damage, loose wiring, or unusual wear. If any issues are found, contact a qualified electrician for repair.

7. Fehlerbehebung

Bevor Sie den Kundendienst kontaktieren, ...view Folgende häufige Probleme und Lösungen:

ProblemMögliche UrsacheLösung
Heizung schaltet sich nicht ein.No power supply; Circuit breaker tripped; Loose wiring.Check circuit breaker; Ensure power switch is in 'HEAT' or 'FAN' position; Consult a qualified electrician to check wiring.
Die Heizung erzeugt keine Wärme, aber der Ventilator läuft.Switch in 'FAN' position; Heating elements failed; Overheat protection activated.Set switch to 'HEAT'; Allow heater to cool if overheat protection tripped; Contact a qualified electrician for element inspection.
Die Heizung schaltet sich häufig ein und aus.Improper thermostat setting (if applicable); Restricted airflow; Overheat protection cycling.Adjust thermostat setting; Clear any obstructions from air inlets/outlets; Ensure proper clearances.
Ungewöhnliche Geräusche oder Gerüche.Loose components; Dust accumulation on elements; Motor issue.Disconnect power immediately; Inspect for loose parts; Clean heater; Contact a qualified electrician for inspection.

Wenn das Problem nach dem Ausprobieren dieser Lösungen weiterhin besteht, wenden Sie sich bitte an den Kundendienst oder einen qualifizierten Elektriker.

8. Spezifikationen

SpezifikationDetail
MarkeKÖNIG
ModellnummerLPWV2715-CT24
Bandtage277 Volt
AmpAlter5.4 Amps
Wastage1500 Watt
Produktabmessungen (T x B x H)4"T x 13.75"B x 22.75"H
Artikelgewicht36 Pfund
MontagetypWandhalterung
KraftstoffartElektrisch
Verwendung im Innen- und AußenbereichInnenbereich
BesonderheitÜberhitzungsschutz
UPC093319183731
ASINB0G3SWW2XK

9. Garantie und Support

For warranty information, technical support, or service inquiries, please refer to the warranty card included with your product or visit the official KING webBewahren Sie Ihren Kaufbeleg als Kaufnachweis für Garantieansprüche auf.

Hersteller: KING Electrical Manufacturing

WebWebsite: www.king-electric.com (Example link, bitte überprüfen Sie die offizielle Version webWebsite)

Zugehörige Dokumente - LPWV2715-CT24

Vorview Installationsanleitung für Cove-Heizgeräte der King KCV-Serie
Offizielle Installationsanleitung für den Cove Heater der King KCV-Serie (Modell KCV1202) mit detaillierten Informationen zu Sicherheitsvorkehrungen, elektrischer Einrichtung, Montage, Verkabelung und Wartung.
Vorview King PSH2440TB Tragbarer Werkstattheizer: Installations-, Betriebs- und Sicherheitshandbuch
Dieses umfassende Handbuch enthält alle wichtigen Informationen zum tragbaren Werkstattheizgerät King PSH2440TB, einschließlich Installations- und Sicherheitshinweisen, Bedienungsanleitung, Wartungstipps und Lösungen zur Fehlerbehebung. Es ist für den Einsatz in Garagen und Werkstätten konzipiert, hat eine Leistung von 3750 W und wird mit 240 V betrieben.
Vorview Elektrischer Raumheizer der King W-Serie: Installations-, Betriebs- und Wartungshandbuch
Umfassende Anleitung für elektrische Raumheizgeräte der King W-Serie mit Informationen zu Installation, Verkabelung, Betrieb, Sicherheitswarnungen, Fehlerbehebung, Wartung und Garantie.
Vorview Installations-, Betriebs- und Wartungshandbuch für elektrische Heizgeräte der King KDSR-Serie
Ausführlicher Leitfaden für elektrische Heizgeräte der King KDSR-Serie (2 kW bis 5 kW) mit Informationen zu Installation, sicherem Betrieb und regelmäßiger Wartung. Enthält wichtige Sicherheitshinweise und Anweisungen für die Montage an Standard- und abgehängten Decken.
Vorview König PX-ECO 2-Stage Electronic Heater: Installation, Operation, and Troubleshooting Guide
Comprehensive guide for the King PX-ECO 2-Stage Electronic Heater, covering installation, wiring diagrams, wattage selection, remote sensor setup, operating instructions, and troubleshooting. Includes safety precautions and maintenance.
Vorview Installations- und Wartungshandbuch für Heizgeräte der Serie King LPW-ECO
Umfassende Anleitung zur Installation, Bedienung und Wartung elektronischer Heizgeräte der Serie King LPW-ECO, einschließlich Sicherheitsanweisungen, Schaltplänen, Einrichtung des Fernsensors und Fehlerbehebung.