The Switch Module Model KBS1 is a versatile device that supports Bluetooth 5.2 SIG Mesh communication protocol, offering strong networking capabilities, reliability, and stability. It enables app control even when manually turned off, catering to diverse needs.

Systemdiagramm

LTECH-KBS1-Switch-Module-fig (1)

Produkteinführung

  • Bluetooth 5.2 SIG Mesh-Kommunikationsprotokoll, das starke Netzwerkfähigkeiten, Zuverlässigkeit und Stabilität bietet.
  • Supports both mechanical and reset switches, enabling app control even when manually turned off to meet diverse needs; supports power-on or power-off scenarios for hotel-style applications.
  • Supports power-on or power-off scenarios to accommodate hotel-style usage scenarios;
  • Unterstützt OTA-Online-Upgrades (Over-the-Air), wodurch zeitnahe Funktionsaktualisierungen und Nutzungssicherheit gewährleistet und das Produkt stets auf dem neuesten Stand gehalten wird.
  • Supports direct connection of mobile phones to devices, enabling direct control of devices through the L-Home app;
  • Supports gateway-free control, enabling LAN remote control, wireless panels, group control, and more.
  • Supports integration with a smart gateway to enable remote control of home devices, making life more convenient.
  • Kompakte Größe, die eine einfache Installation in europäischen, amerikanischen und nationalen Standard-Anschlussdosen ermöglicht und sich für verschiedene Installationsszenarien eignet.
  • Unterstützt die Reset-Funktion bei Stromausfall und die Reset-Funktion mit mechanischen Tasten.

Technische Spezifikationen

Modell KBS1
Kabelloser Typ Bluetooth 5.2 SIG-Mesh
Kanal wechseln 1 Kanäle
Betriebsvolumentage 100-240V~, 50/60Hz,
Maximale Lastparameter des Relais Ohmsche Last: 1000 W bei 230 V AC, 500 W bei 110 V AC; Kapazitive Last: 400 W bei 230 V AC, 200 W bei 110 V AC
Relaisstoßstrom 70A bei 10 ms
Arbeitstemperatur -25°C bis 50°C
Produktgröße L45×B45.5×H20.5(mm)
Produktgewicht 30g
Normen UL 8750、EN 61347-2-13:2014+A1:2017、EN 61347-1:2015+A1:2021、 EN 62493:2015/A1:2022

Produktbilder

LTECH-KBS1-Switch-Module-fig (2)

Produktgröße
Einheit: mmLTECH-KBS1-Switch-Module-fig (3)

Schaltplan

  1. Mechanical Switch Wiring DiagramLTECH-KBS1-Switch-Module-fig (4)
  2. Push Switch Wiring DiagramLTECH-KBS1-Switch-Module-fig (5)

Empfohlene Anwendungen

  1. Drahtlose LichtsteuerungLTECH-KBS1-Switch-Module-fig (6)
  2. Nach der Einrichtung der Fernbedienungszuordnung zum Schaltmodul über die App können sowohl die App als auch die Fernbedienung zur Steuerung des Geräts verwendet werden.LTECH-KBS1-Switch-Module-fig (7)
  3. Unterstützt lokale Szenen, gatewayfreien Betrieb und ist auch offline steuerbar.LTECH-KBS1-Switch-Module-fig (8)
  4. In Verbindung mit einem intelligenten Gateway ermöglicht es die visuelle Steuerung, Cloud-Szenen und die automatische Verknüpfung.LTECH-KBS1-Switch-Module-fig (9)

App Bedienungsanleitung

  1. Konto registrieren
    Scannen Sie den untenstehenden QR-Code mit Ihrem Mobiltelefon und folgen Sie den Anweisungen, um die App-Installation abzuschließen.LTECH-KBS1-Switch-Module-fig (10)
  2. Pairing-Vorgang
    After creating a new home in the APP, click the “+” in the upper right corner on the【Room】interface to add devices. Select “Smart Module” from the device list and follow the on-screen instructions to complete the addition.LTECH-KBS1-Switch-Module-fig (11)
  3. Power On/Off Scene Settings
    On the settings page, you can configure the scenes to be executed when the device powers on or off, along with the execution times for these scenes.LTECH-KBS1-Switch-Module-fig (12)
  4. Binding Interface Settings
    After pairing is complete, enter the Smart Remote/Smart Wireless Switch binding interface. Select the switch module device to associate it. You can then control the device’s power state via the Smart Remote/Smart Wireless Switch. You may also unbind the device from this interface.LTECH-KBS1-Switch-Module-fig (13)
  5. Gruppensteuerung
    Supports grouping identical switch modules or single switches from dual-channel relays (KBS) into clusters. Users can conveniently control power on/off operations for the entire group. To add a device, navigate to the device list, select “Group – Switch Module Group,” modify the group name as prompted, click “Next,” check the devices to include in the group, then save.LTECH-KBS1-Switch-Module-fig (14)
  6. Lokale Szene
    Wechseln Sie zur Seite 【Smart】, klicken Sie oben rechts auf „+“, um eine lokale Szene zu erstellen, und nach Festlegung der Ausführungsaktion können Sie die lokale Verbindung von Bluetooth-Geräten realisieren.LTECH-KBS1-Switch-Module-fig (15)
  7. Cloud-Szenen und Automatisierung
    Make sure that a smart gateway, such as SP-GW-6S,has been added to the family. Cloud scenes: Switch to the 【Smart】 interface and click “+” to create a cloud scene. After setting the execution action, remote linkage can be achieved. Automation: Select “Automation” in the【Smart】page and click “+” to create automation. You can choose local/cloud execution mode,and set trigger conditions and execution actions. When the set trigger conditions are met, a series of device actions are automatically triggered to achieve remote linkageLTECH-KBS1-Switch-Module-fig (16)
  8. Auf Werkseinstellungen zurücksetzen
    Mechanical Reset: Connect device to lighting fixture. Hold reset button for 15s until indicator light flashes red rapidly, then release. Press reset button 3 times briefly within 3s. Slow red flash means factory settings restored; rapid blue flash means setup is complete. Power Cycle Reset: With the power disconnected, use the switch to power on the device for 15 seconds, then power off for 2 seconds. Repeat this power cycle six times (each cycle: 2 seconds on, 5 seconds off). After the seventh power-on cycle, the load lamp will flash three times, indicating a successful reset to factory settings. APP Reset: Click the “LTECH-KBS1-Switch-Module-fig 18 ” on the switch module to enter the main interface, then click the ” ” in the upper right corner to access the settings interface. Click “Delete Device” to complete the reset.LTECH-KBS1-Switch-Module-fig (17)

Aufmerksamkeit

  • Die Installation und Inbetriebnahme des Produkts sollte von einem qualifizierten Fachmann durchgeführt werden.
  • Our company products are and not lightningproof non-waterproof(special models excepted). Please avoid the sun and rain. When installed outdoors, please ensure they are mounted in a water proof enclosure or in an area equipped with lightning protection devices
  • Eine gute Wärmeableitung verlängert die Lebensdauer der Produkte. Bitte sorgen Sie für eine gute Belüftung.
  • Bitte überprüfen Sie, ob das Arbeitsvoltage verwendet entspricht den Parameteranforderungen von Produkten.
  • Der Durchmesser des verwendeten Kabels muss in der Lage sein, die angeschlossenen Leuchten zu belasten und eine feste Verdrahtung zu gewährleisten.
  • Bevor Sie Produkte einschalten, vergewissern Sie sich bitte, dass die gesamte Verkabelung korrekt ist, falls ein falscher Anschluss Schäden an den Leuchten verursacht.
  • Wenn ein Fehler auftritt, versuchen Sie bitte nicht, Produkte selbst zu reparieren. Bei Fragen wenden Sie sich bitte an Ihren Lieferanten.

Gewährleistungsvereinbarung

  • Gewährleistungsfristen ab Lieferdatum: 5 Jahre.
  • Innerhalb der Gewährleistungsfristen werden kostenlose Reparatur- oder Ersatzleistungen bei Qualitätsproblemen erbracht.

Garantieausschlüsse unten:
Following conditions are not wit in the guarantee range of free repairing or replacement servi

  • Über Gewährleistungsfristen hinaus.
  • Jeder künstliche Schaden, der durch hohe Vol. verursacht wirdtage, Überlastung oder unsachgemäße Bedienung.
  • Products with severe physical damage. Damage caused by natural disasters and force majeure.
  • Warranty labels and barcodes have been damaged. No any contract signed by our company.
  1. Die Reparatur oder der Austausch ist die einzige Entschädigung für Kunden. Unser Unternehmen haftet nicht für Neben- oder Folgeschäden, es sei denn, dies ist gesetzlich zulässig.
  2. Unser Unternehmen behält sich das Recht vor, die Bedingungen dieser Garantie zu ändern oder anzupassen; eine schriftliche Freigabeerklärung ist jedoch maßgebend.
    * Dieses Handbuch kann ohne vorherige Ankündigung geändert werden. Produktfunktionen sind von der Ware abhängig. Bei Fragen wenden Sie sich bitte an unsere offiziellen Vertriebspartner.

Häufig gestellte Fragen

F: Kann das Schaltermodul sowohl mit mechanischen als auch mit Rückstellschaltern verwendet werden?

A: Yes, the Switch Module supports both mechanical and reset switches for versatile control options.

F: Wie hoch ist das BetriebsvolumentagReichweite des Schaltmoduls?

A: Die Betriebslautstärketage range is 100-240V~, 50/60Hz, making it suitable for different power systems.

What should I do if the device cannot be found during the search?

Please check the following options: Ensure the device is powered on and functioning properly. Ensure the phone and the device are as close as possible, preferably within 15 meters. Ensure the device has not been added before. If it has, please manually restore it to factory settings.