L3Campus Stackable Managed Switch

Technische Daten

  • Modell: Omada Campus Stackable L3 Managed Switch
  • Front Panel: Mode Selection Button, Management Port, LED,
    Console Port USB2.0 Port (Type-C/RJ45), 1G RJ45 Port, 10G SFP+ Slot
    LED
  • LED-Anzeige:
    • PWR1*: Green On (switch powered by PWR1), Off (PWR2
      disconnected or not working properly)
    • PWR2: Green On (switch powered by PWR1 and PWR2 connected),
      Yellow On** (PWR2 powered), Off (PWR1 disconnected or not working
      richtig)
    • LED SYS FAN: Green On (all fans work properly), Yellow On (not
      all fans work properly)
    • MGMT: On (device linked to port), Flashing (transmitting or
      receiving data), Off (no device linked to port)
    • MST: On (device linked to port), Flashing (transmitting or
      receiving data), Off (no device linked to port)

Anweisungen zur Produktverwendung

Kapitel 2: Installation

Bevor Sie mit der Installation beginnen, vergewissern Sie sich, dass Sie alle haben
the necessary tools and follow safety precautions.

  • Packungsinhalt: Check all items mentioned in
    das Paket.
  • Sicherheitsvorkehrungen: Befolgen Sie die Richtlinien, um
    Gewährleistung einer sicheren Installation.
  • Installationswerkzeuge: Gather all tools required
    zur Installation.
  • Produktinstallation: Folgen Sie der Schritt-für-Schritt-Anleitung
    instructions provided in the manual for successful
    Installation.

Kapitel 3: Verbindung

After installation, connect the switch to the network using
appropriate cables and ports as per your network setup.

Kapitel 4: Konfiguration

Configure the switch based on your requirements. You can choose
between Standalone Mode or Controller Mode as per your network
Bedürfnisse.

Häufig gestellte Fragen

Q: What should I do if the LED indications show an error?

A: If the LED indications suggest improper functioning, check
the power sources and connections. Refer to the troubleshooting
Weitere Hilfe finden Sie im Abschnitt „Hilfe“ im Handbuch.

„`

Business Networking-Lösung
Installationshandbuch
Omada Campus Stackable L3 Managed Switch

Informationen zu diesem Installationshandbuch
Dieses Installationshandbuch beschreibt die Hardwareeigenschaften, Installationsmethoden und die Punkte, die während der Installation beachtet werden sollten. Dieses Installationshandbuch ist wie folgt aufgebaut: Kapitel 1 Einführung Dieses Kapitel beschreibt die externen Komponenten des Switches. Kapitel 2 Installation Dieses Kapitel beschreibt, wie der Switch installiert wird. Kapitel 3 Verbindung Dieses Kapitel beschreibt, wie der Switch physisch angeschlossen wird. Kapitel 4 Konfiguration Dieses Kapitel beschreibt, wie der Switch konfiguriert wird. Anhang A Fehlerbehebung Anhang B Spezifikationen

Publikum

Diese Installationsanleitung ist für:

Netzwerkingenieur

Netzwerkadministrator

Konventionen
· Einige in diesem Handbuch vorgestellte Modelle sind in Ihrem Land oder Ihrer Region möglicherweise nicht verfügbar. Lokale Verkaufsinformationen finden Sie unter https://www.omadanetworks.com/.
· Die Abbildungen in Kapitel 2, Kapitel 3 und Kapitel 4 dienen nur zu Demonstrationszwecken. Ihr Switch kann von der Abbildung abweichen.
· PoE-Budgetberechnungen basieren auf Labortests. Das tatsächliche PoE-Leistungsbudget ist nicht garantiert und kann aufgrund von Kundenbeschränkungen und Umgebungsfaktoren variieren.
· In diesem Handbuch werden spezielle Formate verwendet, um besondere Nachrichten hervorzuheben. In der folgenden Tabelle sind die Hinweissymbole aufgeführt, die in diesem Handbuch verwendet werden.

Denken Sie daran, vorsichtig zu sein. Eine Warnung weist auf ein Potenzial hin, das zu Geräteschäden führen kann.
Erinnern Sie daran, zur Kenntnis zu nehmen. Der Hinweis enthält hilfreiche Informationen für eine bessere Verwendung des Produkts.

Zugehöriges Dokument
Das Benutzerhandbuch und das CLI-Referenzhandbuch des Produkts werden im Download Center bereitgestellt. Um die neuesten Produktinformationen zu erhalten, besuchen Sie das offizielle webWebsite: https://support.omadanetworks.com/document/.

Inhalt
Kapitel 1 Einleitung ———————- 01
1.1 Produktüberschussview ……………………………………………………………..01 1.2 Aussehen………………………………………………………………………..01
Kapitel 2 Installation ———————- 12
2.1 Packungsinhalt ………………………………………………….12 2.2 Sicherheitsvorkehrungen ……………………………………………………………12 2.3 Installationswerkzeuge ……………………………………………………..14 2.4 Produktinstallation ……………………………………………………..14
Kapitel 3 Verbindung ———————- 22
3.1 Ethernet Port …………………………………………………………..22 3.2 10G SFP+/25G SFP28/100G QSFP28 Slot ………..22 3.3 Console Port ……………………………………………………………22 3.4 Verify Installation…………………………………………………….23 3.5 Power On ………………………………………………………………….24 3.6 Initialization………………………………………………………………24 3.7 Stack Topology ……………………………………………………….24
Kapitel 4 Konfiguration ——————– 27
4.1 Konfiguration überview…………………………………………27 4.2 Standalone-Modus……………………………………………………27 4.3 Controller-Modus………………………………………………………28
Anhang A Fehlerbehebung —————- 32
Anhang B Technische Daten —————— 33

Omada Campus Stackable L3 Managed Switch

Kapitel 1 Einführung

1.1 Produktüberschussview
Entwickelt für Unternehmen und campus, Omada Campus Stackable L3 Managed Switch provides wire-speed performance and abundant L2 and L3 management features. It provides a variety of service features and multiple powerful functions with high security. The EIA-standardized framework and smart configuration capacity can provide flexible solutions for a variable scale of networks. Static Routing, RIP, OSPF, BGP, IS-IS, PIM-SM/DM/SSM, and ECMP come with abundant Layer 3 routing protocols that support a scalable network. Physically stacking for builtin redundancy and performance. Redundant power supplies and fans make it an ideal choice for reliable networking architecture. VRRP allows a group of switches to dynamically back up each other. ERPS supports rapid protection and recovery in a ring topology. MACsec, secure boot, ACL, 802.1x and Dynamic ARP Inspection provide robust security strategies. QoS and IGMP snooping/filtering optimize voice and video application. Link aggregation (LACP) increases aggregated bandwidth, optimizing the transport of business critical data. SNMP, RMON, WEB, Netconf and CLI Log-in bring abundant management policies. These switches integrate multiple functions with excellent performance, and is friendly to manage, which can fully meet the need of the users demanding higher networking performance. S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is also a Power Sourcing Equipment (PSE*). The RJ45 ports that support Power over Ethernet (PoE*) function can automatically detect and supply power to those powered devices (PDs*) complying with IEEE 802.3af, IEEE 802.3at, and IEEE 802.3bt (only for S6500-24MPP4Y/S6500-48MPP6Y). *PSE: a device (switch or hub for instance) that provides power through an Ethernet cable. *PoE: This technology describes a system to transmit electrical power, along with data, to remote devices over standard twisted-pair cable in an Ethernet. *PD: a device powered by a PSE and thus consumes energy. ExampZu den Aufgaben gehören die Stromversorgung von Netzwerkkameras, WLAN-Zugangspunkten, IP-Telefonen, Netzwerk-Hubs, eingebetteten Computern usw.
1.2 Aussehen
Front Panel (The figure is for demonstration only. It may differ from your actual product. )
The front panel of S6500-24G4XF is shown as the following figure.
Modusauswahltaste
Verwaltungsport

LED

Console Port USB2.0 Port (Type-C/RJ45)

1G RJ45-Anschluss

10G SFP+ Slot LED

The front panel of S6500-48G6XF is shown as the following figure.
Modusauswahltaste
Verwaltungsport

LED

Console Port USB2.0 Port (Type-C/RJ45)

1G RJ45-Anschluss

10G SFP+ Slot LED

Einleitung 01

Omada Campus Stackable L3 Managed Switch

LED-Anzeige

PWR1*

PWR2

Grün an

Aus

Grün an

Gelb an**

Aus

Grün an

Aus

Aus

Anzeige
Der Schalter wird über PWR1 mit Strom versorgt. PWR2 ist nicht angeschlossen oder funktioniert nicht richtig.
Der Schalter wird von PWR1 mit Strom versorgt. PWR1 und PWR2 sind verbunden.*
Der Schalter wird über PWR2 mit Strom versorgt. PWR1 ist nicht angeschlossen oder funktioniert nicht richtig.
Der Schalter ist ausgeschaltet oder sowohl PWR1 als auch PWR2 funktionieren nicht ordnungsgemäß.

LED SYS FAN
MGMT
MST
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(When the SPEED LED is on)
Port 1-24 of S6500-24G4XF/ Port 1-48 of S6500-48G6XF
(Wenn die STK-LED leuchtet)
Port 25-28 of S6500-24G4XF/ Port 49-54 of S6500-48G6XF ***

Anzeige
Blinkt: Der Schalter funktioniert ordnungsgemäß. An oder Aus: Der Schalter funktioniert nicht richtig.
Grün an: Alle Lüfter funktionieren ordnungsgemäß. Gelb an: Nicht alle Lüfter funktionieren ordnungsgemäß.
On: A device is linked to the port. Flashing: Transmitting or receiving data. Off: No device is linked to the port.
On: The device functions as the master switch in the stack topology or it works individually. Off: The device functions as the member switch in the stack topology.
Grün an: Läuft mit 1000 Mbit/s, aber keine Aktivität. Grün blinkend: Läuft mit 1000 Mbit/s und sendet oder empfängt Daten. Gelb an: Läuft mit 10 Mbit/s/100 Mbit/s, aber keine Aktivität. Gelb blinkend: Läuft mit 10 Mbit/s/100 Mbit/s und sendet oder empfängt Daten. Aus: Es ist kein Gerät mit dem entsprechenden Port verbunden.
Ein: Die Portnummer gibt die Einheiten-ID in der Stapeltopologie an.
Grün an: Läuft mit 10 Gbit/s, aber keine Aktivität. Grün blinkend: Läuft mit 10 Gbit/s und überträgt oder empfängt Daten. Gelb an: Läuft mit 1 Gbit/s, aber keine Aktivität. Gelb blinkend: Läuft mit 1 Gbit/s und überträgt oder empfängt Daten. Aus: Es ist kein Gerät mit dem entsprechenden Port verbunden.

*PWR1 is the primary power supply and it takes priority over PWR2. When the device is powered by PWR1, PWR2 will be working in the backup mode.
**Wenn sowohl PWR1 als auch PWR2 ordnungsgemäß funktionieren und der Schalter durch PWR1 mit Strom versorgt wird, dauert es 10–20 Sekunden, bis die LED PWR2 (gelb) erlischt, nachdem PWR2 ausgesteckt wurde.
***All 10 Gbps SFP+ slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.

02 Einleitung

Omada Campus Stackable L3 Managed Switch The front panel of S6500-24GP4XF is shown as the following figure.

Modusauswahltaste
Verwaltungsport
LED Console Port USB2.0 Port (Type-C/RJ45)

1G RJ45-Anschluss

10G SFP+ Slot LED

Die Vorderseite des S6500-48GP6XF ist in der folgenden Abbildung dargestellt.

Modusauswahltaste
Verwaltungsport
LED Console Port USB2.0 Port (Type-C/RJ45)

1G RJ45-Anschluss

10G SFP+ Slot LED

The front panel of S6500-24M4Y is shown as the following figure.

Modusauswahltaste
Verwaltungsport
LED Console Port USB2.0 Port (Type-C/RJ45)

2.5G RJ45-Anschluss

25G SFP28 Slot LED

The front panel of S6500-24MPP4Y is shown as the following figure.

Modusauswahltaste
Verwaltungsport
LED Console Port USB2.0 Port (Type-C/RJ45)

2.5G RJ45-Anschluss

25G SFP28 Slot LED

Einleitung 03

Omada Campus Stackable L3 Managed Switch The front panel of S6500-48M6Y is shown as the following figure.

Modusauswahltaste
Verwaltungsport

LED Console Port USB2.0 Port (Type-C/RJ45)

2.5G RJ45-Anschluss

The front panel of S6500-48MPP6Y is shown as the following figure.

25G SFP28 Slot LED

Modusauswahltaste
Verwaltungsport
LED Console Port USB2.0 Port (Type-C/RJ45)

2.5G RJ45-Anschluss

25G SFP28 Slot LED

LED Indication LED
PWR1* PWR2
SYS FAN PoE MAX
(For S6500-24GP4XF, S6500-48GP6XF, S6500-24MPP4Y, S6500-48MPP6Y)
MGMT
MST

Anzeige
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Blinkt: Der Schalter funktioniert ordnungsgemäß. An oder Aus: Der Schalter funktioniert nicht richtig.
Grün an: Alle Lüfter funktionieren ordnungsgemäß. Gelb an: Nicht alle Lüfter funktionieren ordnungsgemäß.
Ein: Die verbleibende PoE-Leistung beträgt 7 W. Blinkend: Die verbleibende PoE-Leistung beträgt weiterhin 7 W, nachdem diese LED 2 Minuten lang leuchtet. Aus: Die verbleibende PoE-Leistung beträgt > 7 W.
On: A device is linked to the port. Flashing: Transmitting or receiving data. Off: No device is linked to the port.
On: The device functions as the master switch in the stack topology or it works individually. Off: The device functions as the member switch in the stack topology.

04 Einleitung

Omada Campus Stackable L3 Managed Switch

LED

Anzeige

Port 1-24 of S6500-24GP4XF/
Port 1-48 of S6500-48GP6XF
(When the SPEED LED is on)

Grün an: Läuft mit 1000 Mbit/s, aber keine Aktivität. Grün blinkend: Läuft mit 1000 Mbit/s und sendet oder empfängt Daten. Gelb an: Läuft mit 10 Mbit/s/100 Mbit/s, aber keine Aktivität. Gelb blinkend: Läuft mit 10 Mbit/s/100 Mbit/s und sendet oder empfängt Daten. Aus: Es ist kein Gerät mit dem entsprechenden Port verbunden.

Port 1-24 of S6500-24M4Y & S6500-24MPP4Y/
Port 1-48 of S6500-48M6Y & S6500-48MPP6Y
(When the SPEED LED is on)

Green On: Running at 2.5 Gbps, but no activity. Green Flashing: Running at 2.5 Gbps and transmitting or receiving data. Yellow On: Running at 10 Mbps/100 Mbps/1000 Mbps, but no activity. Yellow Flashing: Running at 10 Mbps/100 Mbps/1000 Mbps and transmitting or receiving data. Off: No device is linked to the corresponding port.

Port 1-24 of S6500-24GP4XF, S6500-24M4Y &
S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF, S6500-48M6Y &
S6500-48MPP6Y
(Wenn die STK-LED leuchtet)

Ein: Die Portnummer gibt die Einheiten-ID in der Stapeltopologie an.

Port 1-24 of S6500-24GP4XF & S6500-24MPP4Y/
Port 1-48 of S6500-48GP6XF & S6500-48MPP6Y
(Wenn die PoE-LED leuchtet)

Green On: The port is supplying power normally. Green Flashing: The supply power exceeds the correponding port’s maximum power. Yellow On: Overload or short circuit is detected. Off: Not providing PoE power on the port

Port 25-28 of S6500-24GP4XF/ Port 49-54 of S6500-48GP6XF ***

Grün an: Läuft mit 10 Gbit/s, aber keine Aktivität. Grün blinkend: Läuft mit 10 Gbit/s und überträgt oder empfängt Daten. Gelb an: Läuft mit 1 Gbit/s, aber keine Aktivität. Gelb blinkend: Läuft mit 1 Gbit/s und überträgt oder empfängt Daten. Aus: Es ist kein Gerät mit dem entsprechenden Port verbunden.

Port 25-28 of S6500-24M4Y & S6500-24MPP4Y/
Port 49-54 of S6500-48M6Y & S6500-48MPP6Y***

Green On: Running at 25 Gbps, but no activity. Green Flashing: Running at 25 Gbps and transmitting or receiving data. Yellow On: Running at 1 Gbps/10 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps/10 Gbps and transmitting or receiving data. Off: No device is linked to the corresponding port.

*By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, S6500-24M4Y/S650048M6Y is shipped with a PSM550-AC power supply module, and S6500-48GP6XF/S6500-24MPP4Y/ S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately.
**By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode: for S6500-24GP4XF/S6500-48GP6XF/S650024MPP4Y/S6500-48MPP6Y, you can specify the primary power supply and the backup power supply according to your needs; for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
***All 10 Gbps SFP+ slots and 25 Gbps SFP28 slots can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.

Einleitung 05

Omada Campus Stackable L3 Managed Switch The front panel of S7500-26XF6Y is shown as the following figure.
Verwaltungsport

LED

Console Port USB3.0 Port

(RJ45/Type-C)

Modusauswahl

Taste

10G SFP+ Slot (Port 1-26)

The front panel of S7500-48XF4C is shown as the following figure.

LED 25G SFP28 Slot (Port 27-32)

Modusauswahltaste
Verwaltungsport
LED Console Port USB3.0 Port (Type-C/RJ45)

10G SFP+ Slot (Port 1-48)

The front panel of S7500-24Y4C is shown as the following figure.

100G QSFP28 Slot LED (Port 49-52)

Verwaltungsport

LED

USB3.0-Anschluss

Konsolenport

(RJ45/Type-C)

Modusauswahltaste

25G SFP28-Steckplatz

LED

(Anschluss 1-24)

The front panel of S7500-48Y8C is shown as the following figure.

100G QSFP28 Slot (Port 25-28)

LED Mode Selection Button

25G SFP28 Slot (Port 1-48)

06 Einleitung

100G QSFP28 Slot (Port 49-56)

Omada Campus Stackable L3 Managed Switch The front panel of S7500-32C is shown as the following figure.

Modusauswahltaste
LED des Verwaltungsports
USB3.0-Anschluss

Console Port (Type-C/RJ45)

100G QSFP28-Steckplatz

LED

Note: S7500-24Y4C and S7500-48Y8C are designed for installation in Network Telecommunications Facilities (NTFs) where ambient temperature and humidity are controlled.

LED Indication LED
PWR1* PWR2
SYS-LÜFTER
MGMT
MST
Port 1-26 of S7500-26XF6Y/ Port 1-48 of S7500-48XF4C
(Wenn die SPD-LED leuchtet)
Port 1-24 of S7500-24Y4C/ Port 1-48 of S7500-48Y8C
(When the SPD/SPEED LED is on)

Anzeige
Green On: The power supply works properly. Green Flashing: The power supply module is not plugged in properly or not compatible with the switch. Yellow On: The power supply works properly but the switch is powered by the other power supply.** Yellow Flashing: The power supply module is plugged in properly but there’s is no AC power input; abnormal power supply. Off: No power supply module is inserted.
Blinkt: Der Schalter funktioniert ordnungsgemäß. An oder Aus: Der Schalter funktioniert nicht richtig.
Grün: Alle Lüfter funktionieren ordnungsgemäß. Gelb: Nicht alle Lüfter funktionieren ordnungsgemäß.
On: A device is linked to the port. Flashing: Transmitting or receiving data. Off: No device is linked to the port.
Notiz:
For S7500-48Y8C, this LED lights green at 1 Gbps and orange at sub-1 Gbps.
On: The device functions as the master switch in the stack topology or it works individually. Off: The device functions as the member switch in the stack topology.
Grün an: Läuft mit 10 Gbit/s, aber keine Aktivität. Grün blinkend: Läuft mit 10 Gbit/s und überträgt oder empfängt Daten. Gelb an: Läuft mit 1 Gbit/s, aber keine Aktivität. Gelb blinkend: Läuft mit 1 Gbit/s und überträgt oder empfängt Daten. Aus: Es ist kein Gerät mit dem entsprechenden Port verbunden.
Green On: Running at 25 Gbps, but no activity. Green Flashing: Running at 25 Gbps and transmitting or receiving data. Yellow On: Running at 1 Gbps/10 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps/10 Gbps and transmitting or receiving data. Off: No device is linked to the corresponding port.

Einleitung 07

Omada Campus Stackable L3 Managed Switch

LED

Anzeige

Port 27-32 of S7500-26XF6Y ***
(Wenn die SPD-LED leuchtet)

Green On: Running at 25 Gbps, but no activity. Green Flashing: Running at 25 Gbps and transmitting or receiving data. Yellow On: Running at 1 Gbps/10 Gbps, but no activity. Yellow Flashing: Running at 1 Gbps/10 Gbps and transmitting or receiving data. Off: No device is linked to the corresponding port.

Port 49-52 of S7500-48XF4C/
Port 25-28 of S7500-24Y4C/ Port 49-56 of S7500-48Y8C/ Port 1-32 of S7500-32C***
(When the SPD/SPEED LED is on)

Grün an: Läuft mit 100 Gbit/s, aber keine Aktivität. Grün blinkend: Läuft mit 100 Gbit/s und überträgt oder empfängt Daten. Gelb an: Läuft mit 40 Gbit/s, aber keine Aktivität. Gelb blinkend: Läuft mit 40 Gbit/s und überträgt oder empfängt Daten. Aus: Es ist kein Gerät mit dem entsprechenden Port verbunden.
Notiz:
For S7500-48XF4C/S7500-48Y8C/S7500-32C, the indication above applies only when the 100 Gbps QSFP28 slots work with common cables. When the slots work with 1-to-4 breakout cables, a single slot is split into four 25 Gbps interfaces. In such scenario, the LED will light green only when all four interfaces are working at 25 Gbps (maximum speed), otherwise it will light yellow. When no device is connected to any of the four interfaces, the LED will be off. (The 100 Gbps QSFP28 slots will support 1-to-4 breakout cables in a future software release.)

Port 1-32 of S7500-26XF6Y/
Port 1-48 of S7500-48XF4C/ Port 1-28 of S7500-24Y4C/ Port 1-56 of S7500-48Y8C
(Wenn die STK-LED leuchtet)

Ein: Die Portnummer gibt die Einheiten-ID in der Stapeltopologie an.

*By default, S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with a PSM550-AC power supply module installed respectively. One more power supply module needs to be purchased separately. **By default, both PWR1 and PWR2 will work simultaneously in the load sharing mode. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply. ***All 25 Gbps SFP28 slots of S7500-26XF6Y and 100 Gbps QSFP28 slots of S7500-48XF4C/S7500-24Y4C/ S7500-48Y8C/S7500-32C can be used as uplink ports or stacking ports. When used as stacking ports, the slots need to run at the highest speed.
Port Introduction (The Management Port, Console Ports, and USB Ports of S7500-48Y8C are located on the rear panel.)
Management Port Designed to connnect the device for management through web, CLI or SNMP. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. Console Port Designed to connect with a computer for monitoring and configuring the switch. When the switch has an RJ45 console port and a Type-C console port, console input is active on only one console port at a time. By default, the Type-C connector takes priority over the RJ45 connector, or you can change the priority through the web. Do not connect this port to any outdoor device, as this may induce surge and lightning damage. USB Port Designed to install the USB flash disk for data storage. 1000M RJ45 Port Designed to connect to the device with a bandwidth of 10Mbps, 100 Mbps or 1000 Mbps. For PoE switches, the port can also provide power for PDs.

08 Einleitung

Omada Campus Stackable L3 Managed Switch
2.5G RJ45 Port Designed to connect to the device with a bandwidth of 10 Mbps, 100 Mbps, 1000 Mbps or 2.5 Gbps. For PoE switches, the port can also provide power for PDs. 10G SFP+ Slot Designed to install the 10 Gbps/1 Gbps optical module. 25G SFP28 Slot Designed to install the 25 Gbps/10 Gbps/1 Gbps optical module. 100G QSFP28 Slot Designed to install the 100 Gbps/40 Gbps optical module. Port Feature

Modell

1000 Mio.

2.5G 10G SFP+ 25G SFP28 100G QSFP28 Management Console USB

RJ45 Port RJ45 Port Slot

Slot

Slot

Hafen

Hafen Hafen

S6500-24G4XF

24

/

4

/

/

S6500-48G6XF

48

/

6

/

/

S6500-24GP4XF

24

/

4

/

/

S6500-48GP6XF

48

/

6

/

/

S6500-24M4Y

/

24

/

4

/

S6500-24MPP4Y

/

24

/

4

/

S6500-48M6Y

/

48

/

6

/

S6500-48MPP6Y

/

48

/

6

/

S7500-26XF6Y

/

/

26

6

/

S7500-48XF4C

/

/

48

/

4

S7500-24Y4C

/

/

/

24

4

S7500-48Y8C

/

/

/

48

8

S7500-32C

/

/

/

/

32

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

1

2

2

Rear Panel (The figure is for demonstration only. It may differ from your actual product. )
The rear panel of S6500-24G4XF/S6500-48G6XF is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

Kensington Security Slot Grounding Terminal Power Socket

Locking Strap Slot

Hinweis: PWR1 ist die primäre Stromversorgung und hat Vorrang vor PWR2.

Einleitung 09

Omada Campus Stackable L3 Managed Switch
The rear panel of S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

Kensington-Sicherheitssteckplatz

LED

Erdungsklemme

Netzteilmodul

LED

Locking Strap Slot

Note: By default, S6500-24GP4XF is shipped with a PSM500-AC power supply module, and S650048GP6XF/S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module. One more power supply module needs to be purchased separately. Both PWR 1 and PWR2 can work simultaneously, or you can specify the primary power supply and the backup power supply according to your needs. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

Erdungsklemme

LED

Power Supply Module Locking Strap Slot

LED

Kensington-Sicherheitssteckplatz

Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode: for S6500-24M4Y/S6500-48M6Y, you can only set PWR1 as the primary power supply and PWR2 as the backup power supply; for S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C, you can specify the primary power supply and the backup power supply according to your needs; Generally, the primary power supply takes priority over the backup power supply.

Die Rückseite des S7500-48Y8C ist in der folgenden Abbildung dargestellt. Die Abbildung dient nur zu Demonstrationszwecken. Ihr Switch kann vom abgebildeten abweichen.

Erdungsklemme

LED

LED

Verschlussriemen

Slot

Netzteilmodul

10 Einleitung

ManagemeC(nTtoyPnposeor-tCle/RPJoU4rt5S)B3P.o0wPeorrSt upplyLoMcokdiSnulgoletStraLpED

Omada Campus Stackable L3 Managed Switch
Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
The rear panel of S7500-32C is shown as the following figure. The figure is for demonstration purposes only. Your switch may differ in appearance from the depicted.

LED-LED
Locking Strap Slot
Power Supply Module Kensington Security Slot

Erdungsklemme

LED
Locking Strap Slot

Netzteilmodul

Note: By default, the device is shipped with a PSM550-AC power supply module installed. One more power supply module needs to be purchased separately. When the switch has two power supply modules installed, both PWR1 and PWR2 will work simultaneously in the load sharing mode by default. They can also work simultaneously in the redundant power supply mode with PWR1 as the primary power supply and PWR2 as the backup power supply. Generally, the primary power supply takes priority over the backup power supply.
Power Supply Module The pluggable power supply module PSM500-AC/PSM900-AC/PSM550-AC is an AC-input power supply module. It can convert the input voltage to 53.5 V (12 V for PSM550-AC) with the maximum output power of 500 W/900 W/550 W respectively. Kensington Security Slot Secure the lock (not provided) into the security slot to prevent the device from being stolen.
Grounding Terminal The switch already comes with lightning protection mechanism. You can also ground the switch through the PE (Protecting Earth) cable of AC cord or with Ground Cable. For detailed lightning protection measures, refer to the Lightning Protection Guide from: https://support.omadanetworks.com/r/1004/. Locking Strap Slot Remove the instruction label and insert the AC power cable locking strap into the slot to secure the power cable.

Einleitung 11

Omada Campus Stackable L3 Managed Switch

Kapitel 2 Installation

2.1 Packungsinhalt

Stellen Sie sicher, dass das Paket die folgenden Artikel enthält. Bitte wenden Sie sich an Ihren Händler, wenn einer der aufgeführten Artikel beschädigt ist oder fehlt. Die Abbildungen dienen nur der Demonstration. Die tatsächlichen Artikel können in Aussehen und Menge von den Abbildungen abweichen.

Schalten

Netzkabel und Konsolenkabel

Installationshandbuch
Business Networking-Lösung
Installationshandbuch
Omada Campus Stackable L3 Managed Switch

Montagehalterungen, Schrauben und Gummifüße

2.2 Sicherheitsvorkehrungen
Um Geräteschäden und Verletzungen durch unsachgemäßen Gebrauch zu vermeiden, sollten Sie die folgenden Regeln beachten.
Sicherheitsvorkehrungen Schalten Sie die Stromversorgung während der Installation aus. Tragen Sie ein ESD-Schutzarmband und stellen Sie sicher, dass das Armband guten Hautkontakt hat und
gut geerdet. Verwenden Sie nur das mit dem Schalter gelieferte Netzkabel. Stellen Sie sicher, dass die Versorgungsspannungtage entspricht den Angaben auf der Rückseite des
Schalter. Stellen Sie sicher, dass der Schalter in einer gut belüfteten Umgebung installiert ist und dass die Belüftungsöffnung nicht
blockiert. Öffnen oder entfernen Sie die Abdeckung des Schalters nicht. Trennen Sie vor der Reinigung des Geräts die Stromversorgung. Reinigen Sie es nicht mit einem feuchten Tuch und
use any other liquid cleaning method. Place the device with its bottom surface facing downwards. Only instructed person or skilled person can be allowed to install, replace, or service this device.
Standortanforderungen
Temperatur/Luftfeuchtigkeit

12 Installation

Omada Campus Stackable L3 Managed Switch Keep the equipment room at an appropriate level of temperature and humidity. Too much or too little humidity may lead to bad insulation, leakage of electricity, mechanical property changes, and corrosion. High temperatures may accelerate aging of the insulation materials, significantly shortening the service life of the device. To find out the best temperature and humidity conditions for the device, check the Appendix B Specifications. Clearness
Der auf dem Schalter angesammelte Staub kann von statischer Elektrizität absorbiert werden und zu einem schlechten Kontakt der Metallkontaktpunkte führen. Es wurden einige Maßnahmen ergriffen, um statische Elektrizität zu verhindern, aber zu starke statische Elektrizität kann die elektronischen Elemente auf der internen Platine tödlich beschädigen. Um die Auswirkungen statischer Elektrizität auf den Betrieb des Schalters zu vermeiden, legen Sie großen Wert auf die folgenden Punkte: Stauben Sie das Gerät regelmäßig ab und halten Sie die Raumluft sauber. Halten Sie das Gerät gut geerdet und stellen Sie sicher, dass die statische Elektrizität abgeleitet wurde. Elektromagnetische Störungen
Elektronische Elemente wie Kapazität und Induktivität des Geräts können durch externe Störungen beeinträchtigt werden, wie z. B. leitungsgebundene Emissionen durch kapazitive Kopplung, induktive Kopplung und Impedanzkopplung. Um die Störungen zu verringern, sollten Sie die folgenden Maßnahmen ergreifen: Verwenden Sie ein Netzteil, das Störungen aus dem Stromnetz effektiv filtern kann. Halten Sie das Gerät von Hochfrequenz- und Starkstromgeräten wie Funksendern fern.
Station. Verwenden Sie bei Bedarf eine elektromagnetische Abschirmung. Blitzschutz
Installation 13

Omada Campus Stackable L3 Managed Switch
Extrem hohe LautstärketagDie Ströme können bei einem Blitzschlag sofort erzeugt werden und die Luft im elektrischen Entladungspfad kann sofort auf bis zu 20,000 °C erhitzt werden. Da dieser Sofortstrom stark genug ist, um elektronische Geräte zu beschädigen, sollten wirksamere Blitzschutzmaßnahmen ergriffen werden. Stellen Sie sicher, dass das Rack und das Gerät gut geerdet sind. Stellen Sie sicher, dass die Steckdose einen guten Kontakt zum Boden hat. Sorgen Sie für ein vernünftiges Verkabelungssystem und vermeiden Sie induzierte Blitze. Verwenden Sie bei der Verkabelung im Außenbereich das Signal SPD (Surge Protective Device).
Hinweis: Ausführliche Informationen zu Blitzschutzmaßnahmen finden Sie im Blitzschutzhandbuch unter: https://support.omadanetworks.com/r/1004/. Installationsort
When installing the device on a rack or a flat workbench, attach much importance to the following items: Install the device with its bottom surface facing down only. This equipment is not suitable for use in locations where children are likely to be present. The rack or workbench is flat, stable, and sturdy enough to support the weight of 9.5 kg at least. The rack or workbench has a good ventilation system. The equipment room is well ventilated. The rack is well grounded. Keep the device less than 1.5 meters away from the power socket.
2.3 Installationswerkzeuge
Kreuzschlitzschraubendreher ESD-vorbeugende Handgelenkwickelkabel
Hinweis: Diese Werkzeuge sind nicht in unserem Produkt enthalten. Bei Bedarf können Sie diese separat erwerben.
2.4 Produktinstallation
Der Schalter ist mit einer Wärmeableitungsfunktion von vorne nach hinten ausgestattet. Wenn er funktioniert, zirkuliert die Luft wie unten gezeigt. Für eine bessere Wärmeableitung installieren Sie das Gerät bitte in einer gut belüfteten Umgebung und lassen Sie 5 bis 10 cm Platz um das Gerät herum.
14 Installation

Abbildung 2-1

Luftzirkulation

Omada Campus Stackable L3 Managed Switch

Desktop-Installation

Um das Gerät auf dem Desktop zu installieren, folgen Sie den Schritten:
1. Stellen Sie das Gerät auf eine ebene Fläche, die stark genug ist, um das gesamte Gewicht des Geräts mit allen Armaturen zu tragen.

2. Entfernen Sie die selbstklebenden Trägerpapiere von den Gummifüßen.

3. Befestigen Sie die Gummifüße an der Unterseite des Geräts, um ein Verrutschen des Geräts auf dem Schreibtisch zu verhindern.

Abbildung 2-2

Desktop-Installation

Füße Unterseite des Geräts Kerbe

Rack-Installation

Im Lieferumfang sind 6 Paare unterschiedlicher Rack-Montagehalterungen enthalten. Die Abbildungen sind unten dargestellt und können vom tatsächlichen Produkt abweichen.

Abbildung 2-3

Montagehalterungen

Screw Hole Group 2

Bracket D Bracket C Bracket B Bracket A

Screw Hole Group 1
Screw Hole Group 3

Halterung F

Screw Hole Group 4-2 (for device with 420mm depth)

Screw Hole Group 5

Schraubenloch

Gruppe 4-1

Screw Hole Group 4-3

(for device with 380mm depth)

(for device with

460mm depth)

Klammer E

Installation 15

Omada Campus Stackable L3 Managed Switch

Before installing the device in an EIA standard-sized, 19-inch rack, please check the efficiency of the grounding system and the stability of the rack, then wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded. Bracket B, C & E have two adjustable ears, please measure the distance between the front-post rack and the rear-post rack, and determine a suitable mounting method from below:

Verfahren

Demonstration

Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket B (Ear towards back)

Rack Distance
(For device with a depth of 380mm)

Rack Distance
(For device with a depth of 420mm)

Rack Distance
(For device with a depth of 460mm)

498-640mm 538-680mm 578-720mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 1) + Bracket C (Ear towards back)

477-498mm 517-538mm 557-578mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards back)

429-477mm 469-517mm 509-557mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket C (Ear towards front)

410-429mm 450-469mm 490-509mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 3) + Bracket C (Ear towards back)

357-410mm 397-450mm 437-490mm

Front: Bracket A Rear: Bracket D (Screw Hole Group 2) + Bracket B (Ear towards back)

282-410mm 322-450mm 362-490mm

16 Installation

Omada Campus Stackable L3 Managed Switch

Front: Bracket A Rear: Bracket F (Screw Hole Group 4) + Bracket E (Ear towards back)

555-936mm 555-936mm 555-936mm

Front: Bracket A Rear: Bracket F (Screw Hole Group 5) + Bracket E (Ear towards back)

743-1121mm 743-1121mm 743-1121mm

Um das Gerät zu installieren, folgen Sie den unten beschriebenen Anweisungen:

1. Attach the M6 nuts to the racks.

Abbildung 2-4

Securing M6 Nuts

×8

2. Attach the mounting brackets (B, C or E) to the rear-post racks and secure them with the provided M6 screws, as illustrated in the following figure.

Abbildung 2-5

Installing Brackets on Racks

or

3. Attach the brackets A & D/F to the switch with the provided M3 screws.

Installation 17

Omada Campus Stackable L3 Managed Switch

Abbildung 2-6

Installing Brackets on Switch

4. After the brackets are attached to the device, hold the switch with attached brackets up until it aligns with the brackets on the racks, and gently push the switch backwards until it is in place, then secure the device on the racks with M6 screws and fix brackets B/C or E to brackets D or F with M4 screws on both sides.

Abbildung 2-7

Installing Switch on Racks

Caution: Leave 5 to 10 cm gaps around the devices for air circulation. Avoid placing heavy things on the device. Mount devices in the order demonstrated above and ensure a certain clearance between devices for
the purpose of heat dissipation.

18 Installation

Omada Campus Stackable L3 Managed Switch

Installation des Stromversorgungsmoduls

S6500-24GP4XF is shipped with a PSM500-AC power supply module installed, S6500-48GP6XF/ S6500-24MPP4Y/S6500-48MPP6Y is shipped with a PSM900-AC power supply module installed, and S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S750032C is shipped with a PSM550-AC power supply module installed. It looks like below, and the image may differ from your actual product.

Abbildung 2-8

Appearance of the Power Supply Module

Netzkabelanschluss
FAN

Halteklammern

Extraction Handle

LED

Locking Strap Slot Release Handle

Wenn Sie ein weiteres Stromversorgungsmodul hinzufügen müssen, befolgen Sie bitte diese Schritte:

1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded.

2. Press the extraction handle of the module with one hand, and hold the bottom of the module using your other hand. Gently push the module in along the slot guide rail.

3. Release the extraction handle to fix the power supply module in place.

Abbildung 2-9

Installieren des Netzteilmoduls

Griff loslassen

Caution: Do not plug the power cord until the power supply module installation is completed. When installing a power supply module, make sure it is set correctly in the operation of installation. Do not use too much force in the installation. If resistance is encountered or positions of the power
supply module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the power supply module is not installed properly. Please check carefully.
The power supply module is designed with a locking strap slot. If you need to secure the power cable with the included locking strap, please follow the steps:
1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded.
Installation 19

Omada Campus Stackable L3 Managed Switch
2. Remove the instruction label on the AC power cable locking strap slot. 3. Attach the clamp to the AC power cable and insert the locking strap into the slot. 4. Adjust tightness and distance of the locking strap using clips to ensure the cable is securely fastened.
Figure 2-10 Installing the Locking Strap

Wenn Sie das Stromversorgungsmodul entfernen müssen, befolgen Sie bitte diese Schritte:
1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well grounded.
2. Depress the retainer clip to release the locking strap, and then remove the power cord from the external power supply system and the power module.
3. Press the extraction handle of the module with one hand, and pull the extraction handle using your other hand, until the module completely comes out of the chassis.
Caution: Unplug the power cord first, then remove the power supply module. When removing a power supply module, make sure that the power supply module is set correctly in the
operation of installation. In order to better protect the power supply module during removal, it is recommended that you
package it in an antistatic bag.
Installation des Lüftermoduls
S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S650048MPP6Y/S7500-26XF6Y/S7500-48XF4C/S7500-24Y4C/S7500-48Y8C/S7500-32C is shipped with hot-swappable fan modules installed. They look like below, and the images may differ from your actual product.
Abbildung 2-11 Aussehen des Lüftermoduls
LED

20 Installation

Extraction Handle Retainer Clips Release Handle

Omada Campus Stackable L3 Managed Switch For normal operation of the switch, please ensure that models with 5 fan modules maintain at least 4 operational modules, while models with 4 fan modules maintain at least 3 operational modules. If one fan module is damaged, please replace it as follows: 1. Wear an ESD-preventive wrist strap, and make sure that it has good skin contact and is well
grounded. 2. Press the extraction handle of the module with one hand, and pull the extraction handle until the
module completely comes out of the chassis.
Abbildung 2-12 Entfernen eines beschädigten Lüftermoduls
3. Press the extraction handle of a new fan module with one hand, and hold the bottom of the module using your other hand. Gently push the module in along the slot guide rail.
4. Release the extraction handle to fix the power supply module in place. Caution: S6500-24GP4XF/S6500-48GP6XF/S6500-24M4Y/S6500-24MPP4Y/S6500-48M6Y/S6500-48MPP6Y/ S7500-26XF6Y uses hot-swappable fan modules with a maximum speed of 9,000 RPM. S7500-48XF4C/ S7500-24Y4C/S7500-48Y8C/S7500-32C uses hot-swappable fan modules with a maximum speed of 18,000 RPM. Please do not interchange or mix fan modules between models. Sharp edges on the fan module may cause injury, so please operate with caution. Make sure the damaged fan module is in place before you are going to replace it. DO NOT unplug the damaged fan module until the replacement operation. Do not use too much force in the replacement. If resistance is encountered or positions of the fan module appear larger during installation, you must first remove the module and then reinstall the module. If the Retainer Clips cannot spring up naturally and the power module is blocked, it may be due to the fan module is not installed properly. Please check carefully.
Installation 21

Omada Campus Stackable L3 Managed Switch

Kapitel 3 Verbindung

3.1 Ethernet-Anschluss

Verbinden Sie einen Ethernet-Anschluss des Switches über ein RJ45-Kabel mit dem Computer, wie in der folgenden Abbildung dargestellt.

Abbildung 3-1

Anschließen des RJ45-Ports

RJ45-Anschluss

RJ45 Kabel

3.2 10G SFP+/25G SFP28/100G QSFP28 Slot

The following figure demonstrates the connection of 10G SFP+/25G SFP28/100G QSFP28 slot to an optical module

Abbildung 3-2

Inserting the Fiber Module

Slot Fiber Module

3.3 Konsolen-Port
CLI (Command Line Interface) ermöglicht Ihnen die Verwaltung des Switches. Sie können die CLI laden, nachdem Sie die PCs oder Terminals über ein Kabel mit dem Konsolenport des Switches verbunden haben (ein RJ45-Konsolenkabel wird mitgeliefert, ein Typ-C-Kabel ist nicht im Lieferumfang enthalten).
Verbinden Sie den RJ45-Konsolenport des Geräts über das Konsolenkabel mit Ihrem Computer, wie in der folgenden Abbildung gezeigt.

22 Anschluss

Abbildung 3-3

Anschließen des Konsolenports (RJ45).

Omada Campus Stackable L3 Managed Switch

Verbinden Sie den Typ-C-Konsolenanschluss des Geräts über das Typ-C-Kabel (nicht im Lieferumfang enthalten) mit Ihrem Computer, wie die folgende Abbildung zeigt.

Abbildung 3-4

Anschließen des Konsolenports (USB).

Note: RJ45 console port and Type-C console port cannot be used concurrently. Type-C Console port takes
priority over the RJ45 console port. The Type-C console port is hot-pluggable while the RJ45 console port is not. Keep the device power
off when plugging the console cable into the RJ45 console port. Do not connect the console port with other ports by RJ45 cable.
3.4 Überprüfen Sie die Installation
Überprüfen Sie nach Abschluss der Installation die folgenden Punkte: Um das Gerät herum sollte ein Freiraum von 5 bis 10 cm zur Belüftung vorhanden sein und der Luftstrom muss
ist ausreichend. Die Voltage des Netzteils erfüllt die Anforderung der Eingangsspannungtage des Geräts. Die Steckdose, das Gerät und das Rack sind gut geerdet. Das Gerät ist korrekt mit anderen Netzwerkgeräten verbunden.
Verbindung 23

Omada Campus Stackable L3 Managed Switch

3.5 Einschalten

Stecken Sie die Buchse des mitgelieferten Netzkabels in die Steckdose des Geräts und den Plusstecker in eine Steckdose, wie in der folgenden Abbildung dargestellt. Stellen Sie sicher, dass die Bdtage des Netzteils erfüllt die Anforderung der Eingangsspannungtage (100-240 V~ 50/60 Hz).

Abbildung 3-5

Anschließen an die Stromversorgung

Note: The figure is to illustrate the application and principle. The provided plug and module in your region
may differ from the figures above. Generally PWR1 takes priority over PWR2.

3.6 Initialisierung
Nachdem das Gerät eingeschaltet wurde, beginnt es mit dem Selbsttest beim Einschalten. Eine Reihe von Tests wird automatisch ausgeführt, um sicherzustellen, dass das Gerät ordnungsgemäß funktioniert. Während dieser Zeit reagieren die LED-Anzeigen in der folgenden Reihenfolge:
1. Die PWR-LED-Anzeige leuchtet ständig. Die SYS-LED und die LED-Anzeigen aller Ports bleiben aus.
2. Nach etwa einer Minute blinken die SYS-LED und die LED-Anzeigen aller Ports kurz auf und erlöschen dann.
3. Einige Sekunden später blinkt die SYS-LED-Anzeige, was eine erfolgreiche Initialisierung darstellt.
3.7 Stapeltopologie
With stackable design, the switches can be stacked into one stack topology for higher reliability, larger bandwidth, and simpler networking. To build the stack topology, you need to prepare 2-12 switches and enough 10G SFP+/25G SFP28/100G QSFP28 modules/cables. For more details, see the table below:

Schalten

Kompatible Modelle

Menge

S6500-24G4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48G6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24GP4XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-48GP6XF S6500-24G4XF, S6500-48G6XF, S6500-24GP4XF, S6500-48GP6XF S6500-24M4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y S6500-24MPP4Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y

2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)

24 Anschluss

Omada Campus Stackable L3 Managed Switch

S6500-48M6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y

S6500-48MPP6Y S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y

S7500-26XF6Y S7500-26XF6Y

S7500-48XF4C S7500-48XF4C

S7500-24Y4C S7500-24Y4C

S7500-48Y8C S7500-48Y8C

S7500-32C

S7500-32C

2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode) 2-12 (max 12 in standalone mode, max 4 in controller mode)

Es gibt drei Stapeltopologiestrukturen für unterschiedliche Szenarien. Bitte erstellen Sie entsprechend Ihren Anforderungen die richtige Topologie:

1. Kettentopologie: Die Kettentopologie ist relativ einfach und erfordert keine Kabelverbindung zwischen der ersten und der letzten Einheit. Sie eignet sich für die Stapelung über große Entfernungen, ihre Zuverlässigkeit ist jedoch relativ gering.

Abbildung 3-6

Kettentopologie

Stapelportgruppe 2
Stapelportgruppe 1

2. Ringtopologie: Die Ringtopologie ist im Vergleich zur Kettentopologie zuverlässiger. Wenn eine der Ketten in der Ringtopologie getrennt wird, wird die Ringtopologie zu einer Kettentopologie, aber das gesamte Stapelsystem kann weiterhin normal funktionieren. Die Ringtopologie erfordert eine Kabelverbindung zwischen der ersten und der letzten Einheit und ist daher nicht für das Stapeln über große Entfernungen geeignet.

Abbildung 3-7

Ringtopologie

Stapelportgruppe 2

Stapelportgruppe 1

Verbindung 25

Omada Campus Stackable L3 Managed Switch

3. Sterntopologie: Die Sterntopologie verbindet die Switches mit einem zentralen Haupt-Switch und kann daher die Datenübertragungsrate zwischen den Mitglieds-Switches erheblich erhöhen und gleichzeitig eine einheitliche Verwaltung ermöglichen.

Abbildung 3-8

Sterntopologie

Stapelportgruppe 2

Stapelportgruppe 3

Stapelportgruppe 1

Note: The stacking port is not allowed to connect to non-stacking port, as it may affect the operation of the
device. Stacking ports with the same group ID are not allowed to connect to stacking ports with different
group IDs, neither to different devices. A stacking port group is a logical port dedicated to stacking and needs to be bound to a stacking port.
A stacking port group can be bound to one or more stacking ports to improve bandwidth and reliability.

26 Anschluss

Omada Campus Stackable L3 Managed Switch

Kapitel 4 Konfiguration

4.1 Konfiguration überview
Der Switch unterstützt zwei Konfigurationsoptionen:
Standalone-Modus: Konfigurieren und verwalten Sie den Switch einzeln. Controller-Modus: Konfigurieren und verwalten Sie die Netzwerkgeräte zentral. Es wird empfohlen, im
Großnetzwerk, das aus Massengeräten wie Access Points, Switches und Gateways besteht.
Hinweis: Wenn der Switch vom Standalone-Modus in den Controller-Modus geändert wird, gehen die Konfigurationen des Switches verloren. Weitere Informationen finden Sie in den entsprechenden Dokumenten im Download-Center unserer offiziellen webWebsite: https://support.omadanetworks.com/product/.

4.2 Standalone-Modus

Verwenden Sie im Standalone-Modus einen Computer, um den Switch über die grafische Benutzeroberfläche (GUI) oder die Befehlszeilenschnittstelle (CLI) zu konfigurieren und zu verwalten.

Abbildung 4-1

Topologie für den Standalone-Modus

Schalten

PC

Verwenden der GUI
1. Um auf die Verwaltungsseite des Switches zuzugreifen, stellen Sie sicher, dass sich Switch und Computer im selben Subnetz befinden. Öffnen Sie einen Browser, geben Sie die IP-Adresse des Switches in das Adressfeld ein und drücken Sie dann die Eingabetaste.
Wenn der Switch die IP-Adresse vom DHCP-Server (normalerweise ein Gateway) erhält, suchen Sie die IP-Adresse des Switches auf dem DHCP-Server.
Wenn nicht, verwenden Sie die Standard-IP-Adresse 192.168.0.1, um die Verwaltungsseite des Switches zu starten.

2. Legen Sie bei der ersten Anmeldung Benutzernamen und Passwort fest, um Ihr Netzwerk und Ihre Geräte besser zu schützen. Anschließend leitet Sie das System automatisch zurück zur Anmeldeoberfläche, um sich mit den neu erstellten Anmeldeinformationen zu authentifizieren.

3. Nach erfolgreicher Anmeldung erscheint die Hauptseite. Sie können auf die Menüs oben und links klicken, um die entsprechenden Funktionen zu konfigurieren.
Detaillierte Konfigurationen finden Sie im Benutzerhandbuch und CLI-Handbuch. Die Anleitungen finden Sie im Downloadcenter unseres offiziellen webWebsite: https://support.omadanetworks.com/product/.
Verwenden der CLI: Richten Sie eine Telnet- oder SSH-Verbindung ein, um über die CLI auf den Switch zuzugreifen.

Konfiguration 27

Omada Campus Stackable L3 Managed Switch

Verwenden Sie den Konsolenport, um auf den Switch zuzugreifen. Wenn Sie den Konsolenport verwenden, starten Sie das Terminalemulationsprogramm (z. B. Hyper Terminal) auf dem PC und konfigurieren Sie das Terminalemulationsprogramm wie folgt:

Baudrate 38400 bps

Datenbits 8

Parität Keine

Stoppbits 1

Flusskontrolle Keine

Detaillierte Konfigurationen finden Sie im Benutzerhandbuch und CLI-Handbuch. Die Anleitungen finden Sie im Downloadcenter unseres offiziellen webWebsite: https://support.omadanetworks.com/product/.
Note: You may need to change the password the first time you log in, which will better protect your network and devices.

4.3 Controller-Modus
Controller Mode applies to the large scale network with mass devices. All devices can be centrally configured and monitored via Omada Pro Hardware Controller (C5300), Omada Pro Software Controller, or Omada Pro Cloud-Based Controller.
Note: Before the following configurations, make sure the switch can access the internet. When using Omada Pro Hardware/Software/Cloud-based Controller, make sure the switch and the controller are in the same subnet. Typically, the switch obtains IP address from the DHCP server. You can check the switch’s IP address on the DHCP server.

Via Omada Pro Hardware Controller (C5300)

Omada Pro Hardware Controller (C5300) is a good alternative if you have no spare PC to keep running Omada Pro Software Controller in the network. It needs to be purchased additionally. Follow the steps below to configure the Omada Pro Hardware Controller (C5300).

Abbildung 4-2

Manage the network via Omada Pro Hardware Controller (C5300)

Gateway-Schalter

Omada Pro Hardware Controller (C5300) EAP
28 Konfiguration

EAP

EAP

Kunden

Omada Campus Stackable L3 Managed Switch

Note: Before you start, be sure to power up and connect your devices according to the topology figure. A DHCP server (typically a gateway with DHCP function enabled) is required to assign IP addresses to
the EAPs and clients in your local network. Omada Pro Controller must have network access to some Omada campus devices (the gateway,
switch, or APs) in order to find, adopt, and manage them.

1. Ermitteln Sie die IP-Adresse des Gateways. Öffnen Sie die Kommandozeile Ihres PCs und geben Sie ipconfig ein. Suchen Sie in der Ergebnisliste nach dem Standard-Gateway, das gleichzeitig die IP-Adresse des Gateways ist.
2. Starten Sie eine web Browser und geben Sie die IP-Adresse des Gateways ein. Melden Sie sich beim Gateway an web Seite. Gehen Sie dann zu Netzwerk > LAN > DHCP-Clientliste, um die IP-Adresse Ihres Controllers entsprechend seiner MAC-Adresse zu finden.
3. Geben Sie die IP-Adresse Ihres Controllers in die Adressleiste ein, um dessen web Seite.
4. On the Omada Pro Controller’s web Folgen Sie auf der Seite dem Assistenten, um die Schnelleinrichtung abzuschließen.
5. Nach der Schnelleinrichtung erscheint die Anmeldeseite. Geben Sie den von Ihnen erstellten Benutzernamen und das Passwort ein und klicken Sie auf Anmelden. Anschließend können Sie den Controller weiter konfigurieren.
6. Wenn Sie die Geräte aus der Ferne verwalten möchten, führen Sie die nächsten Schritte aus:
a. Stellen Sie sicher, dass Cloud Access auf Ihrem Controller aktiviert ist. Standardmäßig ist Cloud Access aktiviert. Stellen Sie sicher, dass die Cloud-LED langsam blinkt.

b. Starten Sie ein web Browser und geben Sie https://omada.tplinkcloud.com in die Adressleiste ein. Geben Sie Ihre TP-Link-ID und Ihr Passwort ein, um sich anzumelden. Klicken Sie auf + Controller hinzufügen und wählen Sie Hardware-Controller, um Ihren Controller hinzuzufügen. Anschließend können Sie den Controller weiter konfigurieren.

For more details, refer to the Installation Guide of C5300.

Über den Omada Pro Software Controller

Download the Omada Pro Software Controller on a PC with Windows OS or Linux OS. Then run the file and follow the wizard to install the Omada Pro Software Controller. Follow the steps below to configure the Controller.

Abbildung 4-3

Verwalten Sie das Netzwerk über den Omada Pro Software Controller

Tor

Schalten

Regler

Omada Pro Software Controller AP

AP

AP

läuft auf dem Host-PC

Kunden

Konfiguration 29

Omada Campus Stackable L3 Managed Switch

1. Launch the Omada Pro Software Controller on your PC. After the initiation process, the controller automatically opens its web Seite. Wenn nicht, klicken Sie auf „Browser zum Verwalten des Netzwerks starten“.
2. On the Omada Pro Controller’s web Folgen Sie auf der Seite dem Assistenten, um die Schnelleinrichtung abzuschließen.
3. Nach der Schnelleinrichtung erscheint die Anmeldeseite. Geben Sie den von Ihnen erstellten Benutzernamen und das Passwort ein und klicken Sie auf Anmelden. Anschließend können Sie den Controller weiter konfigurieren.
4. Wenn Sie die Geräte aus der Ferne verwalten möchten, führen Sie die nächsten Schritte aus:
a. Make sure that Cloud Access is enabled on your controller and your controller has been bound with your TP-Link ID. On the Omada Pro Controller’s web Gehen Sie auf der Seite zu Einstellungen > Cloud-Zugriff, um den Cloud-Zugriff zu aktivieren und Ihre TP-Link-ID zu binden. Wenn Sie ihn in der Schnelleinrichtung eingerichtet haben, überspringen Sie diesen Schritt.
b. Starten Sie ein web Browser und geben Sie https://omada.tplinkcloud.com in die Adressleiste ein. Geben Sie Ihre TP-Link-ID und Ihr Passwort ein, um sich anzumelden. Eine Liste der Controller, die mit Ihrer TP-Link-ID verknüpft wurden, wird angezeigt. Dann können Sie auf Starten klicken, um den Controller weiter zu konfigurieren.

Note: To manage your devices, Omada Pro Software Controller needs to keep running on your computer.

Über den cloudbasierten Omada Pro-Controller

Der cloudbasierte Omada Pro-Controller ist eine gute Alternative, ohne dass der Software-Controller auf einem PC installiert werden muss.

Lizenzen müssen zusätzlich erworben werden.

Abbildung 4-4

Verwalten Sie das Netzwerk über den Omada Pro Cloud-Based Controller

Omada-Wolke

Tor

Schalten

AP

AP

AP

AP

Kunden
1. Contact the sales staff to grant the Omada Pro Cloud-Based Controller permission. 2. Launch a web browser and enter https://omada.tplinkcloud.com in the address bar. Log in with
your TP-Link ID.
30 Konfiguration

Omada Campus Stackable L3 Managed Switch 3. Click + Add Controller and choose Cloud-Based Controller to add an Omada Pro Controller. Then
you can launch the controller to adopt and manage devices. * Omada App With the Omada app, you can also manage your controller at a local site or a remote site via your mobile device. For the detailed configurations, refer to the User Guide of the controller. The guide can be found on the download center of our official webWebsite: https://support.omadanetworks.com/product/.
Konfiguration 31

Omada Campus Stackable L3 Managed Switch
Anhang A Fehlerbehebung
Q1. Was kann ich tun, wenn ich den Benutzernamen und das Passwort des Switches vergessen habe?
1. Verbinden Sie den Konsolenport des PCs mit dem Konsolenport des Switches und öffnen Sie ein Terminalemulationsprogramm.
2. Schalten Sie den Switch aus und starten Sie ihn neu. Führen Sie die vom Terminalemulationsprogramm angegebene Aktion aus, um das BootUtil-Menü zu erreichen. Die Aktion ist von Produkt zu Produkt unterschiedlich. Mögliche Aktionen sind unten aufgeführt: · Drücken Sie eine beliebige Taste, um den Autoboot zu stoppen. · Drücken Sie STRG-B, um das BootUtil-Menü zu erreichen.
3. Das BootUtil-Menü wird angezeigt. Geben Sie die Zahl 6 ein, um die Option „Passwortwiederherstellung“ auszuwählen, und geben Sie Y ein, um alle Benutzer und Passwörter zu löschen. Anschließend können Sie Benutzername und Passwort zurücksetzen.
F2. Warum funktioniert die PWR-LED nicht richtig? Die PWR-/Power-LED sollte leuchten, wenn das Stromversorgungssystem normal funktioniert. Wenn die PWR-/Power-LED nicht richtig funktioniert, führen Sie die folgenden Schritte aus:
1. Stellen Sie sicher, dass das Netzkabel richtig angeschlossen ist und der Stromkontakt normal ist. 2. Stellen Sie sicher, dass die Lautstärketage des Netzteils erfüllt die Anforderung der Eingangsspannungtage der
schalten.
F3. Was soll ich tun, wenn ich keinen Zugriff auf das web Verwaltungsseite? Versuchen Sie Folgendes:
1. Überprüfen Sie alle Port-LEDs am Switch und stellen Sie sicher, dass das Ethernet-Kabel richtig angeschlossen ist. 2. Probieren Sie einen anderen Port am Switch aus und stellen Sie sicher, dass das Ethernet-Kabel geeignet ist und normal funktioniert. 3. Schalten Sie den Switch aus und nach einer Weile wieder ein. 4. Stellen Sie sicher, dass die IP-Adresse Ihres PCs innerhalb des Subnetzes des Switches eingestellt ist. 5. Wenn Sie immer noch nicht auf die Konfigurationsseite zugreifen können, setzen Sie den Switch auf die Werkseinstellungen zurück. Dann
Die IP-Adresse Ihres PCs sollte auf 192.168.0.x eingestellt sein („x“ ist eine beliebige Zahl zwischen 2 und 254) und die Subnetzmaske auf 255.255.255.0.
F4. Warum wird das Terminalemulationsprogramm nicht korrekt angezeigt? Versuchen Sie Folgendes:
1. Stellen Sie sicher, dass die Stromversorgung normal ist und das Konsolenkabel richtig angeschlossen ist. 2. Überprüfen Sie, ob das Konsolenkabel vom richtigen Typ ist. 3. Stellen Sie sicher, dass die Parameter des Terminalemulationsprogramms korrekt sind: Konfigurieren Sie Bits pro Sekunde
als 38400, Datenbits als 8, Parität als Keine, Stoppbits als 1 und Flusskontrolle als Keine.
32 Anhang A Fehlerbehebung

Omada Campus Stackable L3 Managed Switch

Anhang B Spezifikationen

Specifications for S6500 Series Switches

Artikel

Inhalt

IEEE 802.3, IEEE 802.3i, IEEE 802.3u, IEEE 802.3ab, IEEE 802.3z, IEEE 802.3ae, IEEE 802.3x

Normen

IEEE 802.3af/at (For S6500-24GP4XF, S6500-48GP6XF) IEEE 802.3af/at/bt (For S6500-24MPP4Y, S6500-48MPP6Y)

IEEE 802.3bz, IEEE 802.3by, IEEE 802.3cc (For S6500-24M4Y, S6500-24MPP4Y, S6500-48M6Y, S6500-48MPP6Y)

10BASE-T: 2-pair UTP/STP of Cat. 3,4,5 (maximum 100 m) 100BASE-TX: 2-pair UTP/STP of Cat. 5 or above (maximum 100 m) 1000BASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) 2.5GBASE-T: 4-pair UTP/STP of Cat. 5e or above (maximum 100 m) Transmission Medium 1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M)

S6500-24G4XF/S6500-24M4Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-24, Port 25-28 S6500-24GP4XF/S6500-24MPP4Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-24, Port 25-28 LED S6500-48G6XF/S6500-48M6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, Port 1-48, Port 49-54 S6500-48GP6XF/S6500-48MPP6Y: PWR1, PWR2, SYS, FAN, PoE Max, MGMT, MST, SPEED, STK, PoE, Port 1-48, Port 49-54

Anhang B Spezifikationen 33

Omada Campus Stackable L3 Managed Switch

PoE-Budget

For S6500-24GP4XF: 402W (with 1*PSM500-AC, by default) 720W (with 1*PSM900-AC) 720W (with 2*PSM500-AC) 720W (with 1*PSM500-AC and 1*PSM900-AC) 720W (with 2*PSM900-AC) For S6500-48GP6XF: 764W (with 1*PSM900-AC, by default) 384W (with 1*PSM500-AC) 812W (with 2*PSM500-AC) 1176W (with 1*PSM500-AC and 1*PSM900-AC) 1440W (with 2*PSM900-AC) For S6500-24MPP4Y: 751W (with 1*PSM900-AC, by default) 378W (with 1*PSM500-AC) 802W (with 2*PSM500-AC) 1168W (with 1*PSM500-AC and 1*PSM900-AC) 1534W (with 2*PSM900-AC) For S6500-48MPP6Y: 701W (with 1*PSM900-AC, by default) 328W (with 1*PSM500-AC) 752W (with 2*PSM500-AC) 1118W (with 1*PSM500-AC and 1*PSM900-AC) 1484W (with 2*PSM900-AC)

Operating Temperature & Altitude

For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters

Lagertemperatur -40 °C bis 70 °C (-40 °F bis 158 °F)

Betriebsfeuchtigkeit 10 % bis 90 % relative Luftfeuchtigkeit, nicht kondensierend

Luftfeuchtigkeit bei Lagerung

5 % bis 90 % relative Luftfeuchtigkeit, nicht kondensierend

34 Anhang B Spezifikationen

Omada Campus Stackable L3 Managed Switch

Specifications for S7500 Series Switches

Artikel

Inhalt

Normen

IEEE 802.3, IEEE 802.3x IEEE 802.3z, IEEE 802.3ae (For S7500-26XF6Y, S7500-48XF4C, S7500-24Y4C, S7500-48Y8C IEEE 802.3by, IEEE 802.3cc (For S7500-26XF6Y, S7500-24Y4C, S7500-48Y8C) IEEE 802.3 ba, IEEE 802.3bm (For S7500-48XF4C , S7500-24Y4C, S7500-48Y8C, S7500-32C)

1000BASE-SX/LX/LX10/BX10: MMF, SMF 10GBASE-SR/LR: MMF, SMF 10G SFP+ Direct Attach Cable (SM5220-1M, SM5220-3M) 25GBASE-SR/LR: MMF, SMF (SM6110-SR, SM6110-LR) 25G SFP28 Direct Attach Cable (SM6220-1M) 40GBASE-SR4/LR4: MMF, SMF (For S7500-48XF4C, S7500-24Y4C, Transmission Medium S7500-48Y8C, S7500-32C) 40G QSFP+ Direct Attach Cable (For S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100GBASE-SR4/LR4: MMF, SMF (SM9110-SR4 for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C) 100G QSFP28 Direct Attach Cable (SM9220-1M for S7500-48XF4C, S7500-24Y4C, S7500-48Y8C, S7500-32C)

LED
Operating Temperature & Altitude

S7500-26XF6Y: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP+, SFP28 S7500-48XF4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP+, QSFP28 S7500-24Y4C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPD, STK, SFP28, QSFP28 S7500-48Y8C: PWR1, PWR2, SYS, FAN, MGMT, MST, SPEED, STK, SFP28, QSFP28 S7500-32C: PWR1, PWR2, SYS, MGMT, FAN, MST, SPEED, STK, QSFP28 -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters

Lagertemperatur -40 °C bis 70 °C (-40 °F bis 158 °F)

Betriebsfeuchtigkeit 10 % bis 90 % relative Luftfeuchtigkeit, nicht kondensierend

Luftfeuchtigkeit bei Lagerung

5 % bis 90 % relative Luftfeuchtigkeit, nicht kondensierend

For S7500-26XF6Y, S7500-48XF4C, and S7500-24Y4C, the maximum operating temperature supported can reach 50 °C (122 °F) @ 300 meters, 45 °C (113 °F) @ 2,000 meters, and 40 °C (104 °F) @ 3,000 meters.
Die unterstützte Höhe reicht vom Meeresspiegel bis 5000 m. Es ist zu beachten, dass bei einer Höhe über 2000 m die maximale Betriebstemperatur pro 220 Höhenmeter um 1 °C (1.8 °F) sinkt.

Anhang B Spezifikationen 35

Omada Campus Stackable L3 Managed Switch

Spezifikationen für Stromversorgungsmodule

PSM500-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)

PSM900-AC
(For S6500-24GP4XF/ S6500-48GP6XF/ S6500-24MPP4Y/ S6500-48MPP6Y)

PSM550-AC
(For S6500-24M4Y/ S6500-48M6Y/ S7500-26XF6Y/ S7500-48XF4C/ S7500-24Y4C/ S7500-48Y8C/ S7500-32C)

Leistungsaufnahme

100 V­240 V~ 50/60 Hz 8A

100-120V (included)~ 50/60Hz 12A (for locations using low voltage, see specifications for specific countries/ regions)
120 (not included)240V~ 50/60Hz 10A (for other locations)

100 V­240 V~ 50/60 Hz 7A

Ausgangsvolumentage

Primary: 53.5 VDC Standby: 12 VDC

Primary: 53.5 VDC Standby: 12 VDC

Primary: 12 VDC Standby: 12 VDC

Ausgangsstrom

9.35 A (maximal)

16.5 A (maximal)

45 A (maximal)

Ausgangsleistung

500 W (maximal)

900 W (maximal)

550 W (maximal)

Höhe über NN bei Betrieb

For PSM500-AC/PSM900-AC: Sea level to 3000 m For PSM550-AC: Sea level to 5000 m

36 Anhang B Spezifikationen

CE-Kennzeichnungshinweis
Dies ist ein Produkt der Klasse A. In einer Wohnumgebung kann dieses Produkt Funkstörungen verursachen. In diesem Fall muss der Benutzer möglicherweise entsprechende Maßnahmen ergreifen.
EU-Konformitätserklärung
TP-Link erklärt hiermit, dass der Switch den grundlegenden Anforderungen und anderen relevanten Bestimmungen der Richtlinien 2014/30/EU, 2014/35/EU, 2011/65/EU und (EU)2015/863 entspricht. Die ursprüngliche EU-Konformitätserklärung finden Sie unter https://www.tp-link.com/en/support/ce/
Britische Konformitätserklärung
TP-Link erklärt hiermit, dass der Switch den grundlegenden Anforderungen und anderen relevanten Bestimmungen der Verordnung zur elektromagnetischen Verträglichkeit 2016 und der Verordnung zur Sicherheit elektrischer Geräte 2016 entspricht. Die ursprüngliche britische Konformitätserklärung finden Sie unter https://www.tp-link.com/support/ukca/
, .
VORSICHT:
Zweipolige, neutrale Sicherung. Trennen Sie vor Wartungsarbeiten die Netzspannung.
Sicherheitshinweise
· Halten Sie das Gerät von Wasser, Feuer, Feuchtigkeit oder heißen Umgebungen fern. · Versuchen Sie nicht, das Gerät zu zerlegen, zu reparieren oder zu modifizieren. Wenn Sie Service benötigen, wenden Sie sich bitte an uns. · Legen Sie das Gerät mit der Unterseite nach unten. · Der Stecker am Netzkabel dient zum Trennen der Stromversorgung, die Steckdose muss
leicht zugänglich. · Schließen Sie das Produkt über das Netzkabel an eine Steckdose mit Erdungsanschluss an
or plug. · The socket-outlet shall be installed near the equipment and shall be easily accessible. · The PoE ports shall not be used to charge lithium batteries or devices supplied by lithium
Batterien.

· Operating temperature: For S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/ S7500-48XF4C/S7500-24Y4C: -5 °C to 50 °C (23 °F to 122 °F) @ 300 meters -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters For S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y: -5 °C to 45 °C (23 °F to 113 °F) @ 2,000 meters -5 °C to 40 °C (23 °F to 104 °F) @ 3,000 meters S7500-48Y8C/S7500-32C: -5 °C to 45 °C (23 °F to 113 °F) @ 300 meters -5 °C to 40 °C (23 °F to 104 °F) @ 2,000 meters -5 °C to 35 °C (23 °F to 95 °F) @ 3,000 meters
· : S6500-24G4XF/S6500-48G6XF/S6500-24M4Y/S6500-48M6Y/S7500-26XF6Y/S7500-48XF4C/ S7500-24Y4C -5°C 50°C23°F 122°F@ 300 -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S6500-24GP4XF/S6500-48GP6XF/S6500-24MPP4Y/S6500-48MPP6Y -5°C 45°C23°F 113°F@ 2,000 -5°C 40°C23°F 104°F@ 3,000 S7500-48Y8C/S7500-32C -5°C 45°C23°F 113°F@ 300 -5°C 40°C23°F 104°F@ 2,000 -5°C 35°C23°F 95°F@ 3,000
This equipment is not suitable for use in locations
where children are likely to be present.

Bitte lesen und befolgen Sie die oben genannten Sicherheitshinweise, wenn Sie das Gerät bedienen. Wir können nicht garantieren, dass durch unsachgemäßen Gebrauch des Geräts keine Unfälle oder Schäden auftreten. Bitte verwenden Sie dieses Produkt mit Sorgfalt und bedienen Sie es auf eigene Gefahr.

Technischen Support, Benutzerhandbücher und weitere Informationen erhalten Sie unter https://support.omadanetworks.com/ oder scannen Sie einfach den QR-Code.