SoliTek SOLID Series Solar Modules Installation Guide

SoliTek SOLID Series Solar Modules Installation Guide

SoliTek-LOGO

SoliTek SOLID Series Solar Modules

SoliTek-SOLID-Series-Solar-Modules-PRODUCT

Gebrauchsanweisung

  • Read this guide entirely before installation.
  • This document provides minimum requirements and recommendations for safe and successful installation of SoliTek PV modules and is necessary to retain compliance with IEC 61215, IEC 61730, and UL 61730 standards.
  • This guide provides basic information on JSC SoliTek Cells SOLID series photovoltaic modules, including their installation and safe handling.
  • All instructions should be read and understood before attempting installation. Contact your dealer or JSC SoliTek Cells for further information if needed.
  • This documentation refers to the PV modules themselves and is not a comprehensive installation manual for personnel not specifically trained in PV modules.
  • It serves as a general but strictly mandatory reference for the installer. Infringement or inaccurate observance of any clause in this documentation voids the warranty.
  • The installer must understand and follow all applicable local, state, and federal regulations and standards for building construction, electrical design, fire, and safety.
  • Check with local authorities for permitting requirements before installing or maintaining PV modules, and become familiar with mechanical and electrical requirements for photovoltaic systems.
  • Die Nichtbeachtung der Anweisungen in diesem Handbuch kann zu Schäden an Systemkomponenten, einer Gefährdung des Personals oder Sachschäden führen oder zum Erlöschen der Panel-Garantie führen.
  • Rooftop PV systems should only be installed on dwellings formally analyzed for structural integrity and confirmed to be capable of handling the additional weighted load of PV system components (including PV modules) by a certified building specialist or engineer.

ALLGEMEINE ANFORDERUNGEN

  • Bitte lesen Sie diese Anleitung vor der Installation vollständig durch.
  • Der Zweck dieses Dokuments besteht darin, Mindestanforderungen und Empfehlungen für eine sichere und erfolgreiche Installation von SoliTek PV-Modulen bereitzustellen.
  • Dieses Dokument enthält außerdem die notwendigen Anforderungen, um die Konformität des SoliTek PV-Moduls mit den Normen IEC 61215, IEC 61730 und UL 61730 aufrechtzuerhalten.
  • Dieses Handbuch enthält grundlegende Informationen zu Photovoltaikmodulen der SOLID-Serie von JSC „SoliTek Cells“, ihrer Installation und sicheren Handhabung. Alle Anweisungen sollten vor der Installation gelesen und verstanden werden. Bei Fragen wenden Sie sich für weitere Informationen bitte an Ihren Händler oder an JSC „SoliTek Cells“.
  • This documentation refers to the PV-modules themselves and is not meant to be a complete installation manual for personnel not specifically trained to PV-modules.
  • It serves as a general but strictly mandatory reference for the Installer.
  • Bei Verstoß oder nicht ordnungsgemäßer Befolgung einer Klausel dieser Dokumentation erlischt die Garantie.
  • Der Installateur muss alle geltenden lokalen, staatlichen und bundesstaatlichen Vorschriften und Normen für Gebäudekonstruktion, elektrische Konstruktion, Brandschutz und Sicherheit verstehen und befolgen und sich bei den örtlichen Behörden erkundigen, um die geltenden Genehmigungsanforderungen zu ermitteln, bevor er versucht, PV-Module zu installieren oder zu warten, und sollte dies tun lernen Sie die mechanischen und elektrischen Anforderungen an Photovoltaikanlagen kennen.
  • Bei Nichtbefolgen der Anweisungen in diesem Handbuch können Systemkomponenten beschädigt werden, Personen gefährdet werden, Eigentum beschädigt werden oder die Garantie für das Panel erlöschen.
  • PV-Dachsysteme sollten nur auf Wohngebäuden installiert werden, deren strukturelle Integrität offiziell analysiert wurde und von einem zertifizierten Baufachmann oder Ingenieur bestätigt wurde, dass sie der zusätzlichen Gewichtslast von PV-Systemkomponenten, einschließlich PV-Modulen, standhalten können.
  • For your safety, do not attempt to work on a rooftop until safety precautions have been identified and taken, including, without limitation fall protection measures, ladders or stairways, and personal protective equipment (PPE).
  • For your safety, do not install or handle PV modules under adverse conditions, including, without limitation strong or gusty winds, and wet or frosted roof surfaces.
  • Die Flachplatten-PV-Modulkonstruktion besteht aus einer laminierten Anordnung von Solarzellen, die in einem isolierenden Material in zwei Glasscheiben eingekapselt sind.
  • Bewahren Sie diese Dokumentation zum späteren Nachschlagen an einem sicheren Ort auf.
  • Versuchen Sie nicht, das Modul zu zerlegen und entfernen Sie keine angebrachten Typenschilder oder Komponenten! Andernfalls erlischt die Garantie.

Handhabung & Anwendung

HANDHABUNG

  • SoliTek PV modules must be transported in the supplied packaging only and kept in the packaging until they are ready to be installed.
  • Protect pallets against movement and exposure to damage during transportation. Secure pallets from falling over.
  • Überschreiten Sie nicht die maximale Höhe der zu stapelnden Paletten, wie auf der Palettenverpackung angegeben.
  • Store pallets in a cool and dry location until the PV modules are ready to be unpackaged.
  • SoliTek PV modules are heavy and should be handled with care. Never use the junction box or cables as a grip.
  • Do not exert mechanical stress on the cables.
  • Never step on PV modules or drop or place heavy objects on them.
  • Be careful when placing PV modules on hard surfaces and secure them from falling.
  • Broken glass can result in personal injury. PV modules with broken glass cannot be repaired and must not be used.
  • Broken or damaged PV modules must be handled carefully and disposed of properly.

ANWENDUNG

Einschränkungen

  • SoliTek PV modules must be mounted on appropriate mounting structures positioned on suitable buildings, the ground, or other structures suitable for PV modules (e.g. carports, building facades or PV trackers).
  • PV modules must not be mounted on moving vehicles of any kind. Modules must not be installed in locations where they could be submerged in water.
  • Do not install modules above 2000 m (6561 ft) altitude above sea level
  • Künstlich gebündeltes Licht darf nicht auf SoliTek PV-Module gerichtet werden.

Empfehlungen

  • SoliTek empfiehlt, PV-Module mit einem Neigungswinkel von mindestens 10 Grad zu montieren, um eine ordnungsgemäße Selbstreinigung durch Regen zu ermöglichen.
  • Eine teilweise oder vollständige Beschattung eines oder mehrerer PV-Module kann die Systemleistung erheblich verringern.
  • SoliTek empfiehlt, die Schattenmenge das ganze Jahr über zu minimieren, um die von den PV-Modulen erzeugte Energiemenge zu erhöhen.
  • Hohe Systemlautstärketages could be induced in the event of an indirect lightning strike, which could cause damage to PV system components.
  • The open area of wire loops should be minimized in order to reduce the risk of lightning-induced voltage Wellen.
  • Bessere Modulbelüftung und kürzere Anschlusskabel erhöhen die elektrische Energieerzeugung.

Für bifaziale Module:

  • Es wird empfohlen, die Höhe der PV-Module über dem Boden zu erhöhen, damit mehr Licht unter das Modul gelangen und dann reflektiert werden kann.
  • Der bifaziale Gewinn erhöht sich deutlich, wenn Module über weißen (hoher Albedowert), lichtreflektierenden Flächen installiert werden.

Elektrische Installation

SICHERHEIT

  • PV-Module können Strom und Volumen produzierentage bei Lichteinwirkung jeder Intensität. Der elektrische Strom steigt mit höherer Lichtintensität. DC-Voltage von 50 Volt oder höher ist potenziell tödlich. Der Kontakt mit stromführenden Schaltkreisen einer unter Licht betriebenen PV-Anlage kann zu einem tödlichen Stromschlag führen.
  • Schalten Sie PV-Module spannungsfrei, indem Sie sie vollständig aus dem Licht nehmen oder ihre Vorderseite mit einem lichtundurchlässigen Material abdecken. Beachten Sie die Sicherheitsvorschriften für stromführende elektrische Geräte beim Arbeiten mit Modulen, die Licht ausgesetzt sind. Verwenden Sie isoliertes Werkzeug und tragen Sie keinen Metallschmuck beim Arbeiten mit PV-Modulen.
  • Um Lichtbögen und Stromschläge zu vermeiden, trennen Sie elektrische Verbindungen nicht unter Last. Auch fehlerhafte Verbindungen können zu Lichtbögen und Stromschlägen führen. Halten Sie Steckverbinder trocken und sauber und stellen Sie sicher, dass sie in einwandfreiem Zustand sind. Führen Sie niemals metallische Gegenstände in die Steckverbinder ein oder verändern Sie diese in irgendeiner Weise, um eine elektrische Verbindung zu sichern.
  • Do not touch or handle PV modules with broken glass unless the PV modules are first disconnected, and you are wearing proper PPE. Avoid handling PV modules when they are wet unless cleaning the PV modules as directed in this manual. Never touch electrical and wet connections without protecting yourself with insulated gloves.
  • The modules are qualified for Class II protection against electrical shock, in accordance with clause 4 of IEC 61730-1:2016, which can be used in systems operating at > 50 V DC or >240 W, where general contact access is anticipated and modules qualified for safety through UL 61730 within this application class are considered to meet the requirements of Safety Class II.
  • Die Installation von Photovoltaikanlagen erfordert spezielle Fähigkeiten und Kenntnisse. Sie darf nur von qualifiziertem und speziell eingewiesenem Personal durchgeführt werden. Der Installateur übernimmt alle Verletzungsrisiken, einschließlich der Gefahr eines Stromschlags.
  • Verwenden Sie nur Geräte, Anschlüsse, Kabel und Montageteile, die speziell für den Einsatz in einem Photovoltaiksystem ausgelegt sind.
  • Before any manipulation at an installed PV plant, switch it off first on the AC-side, and then on the DC side of the inverter or the charge controller.
  • Beim Trennen von Leitungen, die an ein Photovoltaikmodul angeschlossen sind, das Licht ausgesetzt ist, kann ein Lichtbogen entstehen. Lichtbögen können Verbrennungen verursachen, Brände auslösen oder auf andere Weise Sicherheitsprobleme (bis hin zu tödlichen Stromschlägen) verursachen.
  • Überprüfen Sie die verbleibende Voltage before starting and observe the local safety-relevant regulations for such working conditions.
  • Unter normalen Bedingungen kann ein Photovoltaikmodul mehr Strom und/oder Volumen produzierentage (hier: 30 V DC) als unter Standardtestbedingungen angegeben.
  • Kontakt mit einem DC voltage von 30 V oder mehr ist potenziell gefährlich. Seien Sie vorsichtig, wenn Sie Module verdrahten oder handhaben, die dem Sonnenlicht ausgesetzt sind.
  • Nur Module mit gleichem Nennausgangsstrom in Reihe schalten. Bei Reihenschaltung von Modulen ist das Gesamtvoltage ist gleich der Summe der einzelnen Modulvoltages.
  • Schließen Sie nur Module oder Reihenkombinationen von Modulen mit gleichem Volumen antage in parallel. If modules are connected in parallel, the total current is equal to the sum of the individual module or series combination currents.
  • Verwenden Sie immer denselben Modultyp innerhalb einer bestimmten Photovoltaikanlage.
  • If the sum of short circuit currents of the parallel-connected modules exceeds the reverse current, string diodes or fuses have to be used in each string of modules connected in parallel. These string diodes or fuses have to be qualified for the maximum expected current and voltage. The fuse rating value is also corresponds to the maximum reverse current that a module can withstand. The reverse current value can be found on the product label, in the product datasheet or in chapter 8 of the installation manual. Observe the instructions and safety precautions for all other components used in the system, including wiring and cables, connectors, DC-breakers, inverters, etc.
  • Verwenden Sie geeignete Sicherheitsausrüstung (isolierte Werkzeuge, dielektrische Handschuhe, Schuhe usw.), die für den Einsatz an elektrischen Anlagen zugelassen ist.

KONFIGURATION

  • Unter normalen Bedingungen ist ein Photovoltaikmodul wahrscheinlich Bedingungen ausgesetzt, die mehr Strom und/oder Volumen erzeugentage than reported at Standard Test Conditions (STC: 1000 W/ m2, AM 1.5, and 250C/770F cell temperature) or Bifacial nominal power index(BNPl front irradiance 1000 W/m2, back irradiance 135 W/m2 AM 1.5, and 25 OC/770F cell temperature). The short-circuit current (ISC) should be multiplied by a factor of 1.25 and the open-circuit voltage (VOC) sollte bei der Bestimmung des Bauteilvolumens mit einem Faktor von bis zu 1.25 multipliziert werden, basierend auf der niedrigsten und höchsten gemessenen Umgebungstemperatur am Installationsorttage-Nennwerte, Leiterstromnennwerte, Sicherungsgrößen und Größe der an den PV-Ausgang angeschlossenen Steuerungen.
  • BandtagBei direkter Reihenschaltung von PV-Modulen addieren sich diese, bei direkter Parallelschaltung von PV-Modulen addieren sich die Modulströme. PV-Module mit unterschiedlichen elektrischen Eigenschaften dürfen nicht direkt in Reihe geschaltet werden. Die Verwendung geeigneter elektronischer Fremdgeräte, die an PV-Module angeschlossen werden, können andere elektrische Anschlüsse ermöglichen und müssen gemäß den Anweisungen des Herstellers installiert werden.
  • Die maximale Lautstärketage of serial interconnection of the modules must be less than the maximum certified module’s system voltage. Auch die maximale Eingangslautstärketage des Wechselrichters und der anderen elektrischen Geräte im System müssen berücksichtigt werden. Der offene Stromkreis voltage of the array string needs to be calculated at the lowest expected a mbient temperature forthe location. The maximal system voltage for the module is indicated in the module’s datasheet.
  • Accordingly, for BLACKSTAR, SOLID or MAGNUS series modules, the values of ISC and VOC under STC or BNPI marked on this module should be multiplied by a factor of 1,25 when determining component voltage ratings, conductor current ratings, fuse sizes, and size of controls connected to the PV output. In the USA, referto Section 690-8 of the National Electrical Code (N EC) for an additional multiplying factor of 125 percent (80 percent de-rating) which may be applicable.

ÜBERSTROMSCHUTZEINRICHTUNG (OCPD)

  • When the potential reverse current of a PV string exceeds the rated SoliTek PV module series fuse rating (values indicated at the module datasheet) an overcurrent protection device (OCPD) must be used.
  • An overcurrent protection device is required for each series string if more than two series are connected in parallel.
  • In this case, it is needed to use one fuse per string rated at 1.25 x Isc or higher (Isc is the PV module’s short circuit current at STC). A PV fuse on each PV string will protect the PV modules and conductors from overcurrent faults and help minimize any safety hazards.
  • The PV fuse will also isolate the faulted PV string so the balance of the PV system can continue to generate electricity.
  • Sicherung amp Bewertung ≥ 1.25 x Isc
  • Wählen Sie im Katalog der verfügbaren PV-Sicherungen den nächsthöheren Standardwert aus.
  • Isc = Kurzschlussstrom eines Moduls unter Standardtestbedingungen (STC).
  • Unter Berücksichtigung der Isc-Werte der SoliTek-Module beträgt der richtige Wert der bei der Installation zu verwendenden PV-Sicherungen 30 A. SoliTek empfiehlt die Verwendung von PV-Sicherungen sowohl im Plus- als auch im Minusleiter.

KABEL & VERDRAHTUNG

SoliTek PV-Module werden mit zwei standardmäßigen, sonnenlichtbeständigen Ausgangskabeln geliefert, die mit PV-Steckern abgeschlossen sind und für die meisten Installationen bereit sind. Der Pluspol (+) verfügt über einen Stecker, während der Minuspol (-) über eine Buchse verfügt. Die Modulverkabelung ist für Reihenschaltungen (d. h. Verbindungen zwischen Stecker (+) und Buchse (-)) vorgesehen, kann aber auch zum Anschluss geeigneter Elektrogeräte von Drittanbietern verwendet werden, die möglicherweise über alternative Verkabelungskonfigurationen verfügen, sofern die Anweisungen des Herstellers befolgt werden.
Verwenden Sie Feldverkabelungen mit geeigneten Querschnittsflächen, die für den Einsatz beim maximalen Kurzschlussstrom des PV-Moduls zugelassen sind. Bei der gesamten Verkabelung muss es sich um doppelt isolierte, vernetzte Kabel mit einer Mindestspannung von 1,8 kV (über 1500 V Vol.) handelntage) und eine Mindestnenntemperatur von 90 °C (190 °F). Drahtgröße nicht weniger als 4 mm² (12 AWG). Der Isolationstyp sollte für die Art der verwendeten Installationsmethode geeignet sein und die Anforderungen von IEC 61730 und Sicherheitsklasse II erfüllen.

  • Isolationsniveau: 1,8 kV (Leiter-Leiter).
  • Temperatur: mindestens -40 °C bis +90 °C (-40 °F bis 190 °F).
  • Aufbau des Leiters: verzinnte Kupferlitze mit einer Kupferreinheit von mehr als 99,9 %.
  • Primärisolierung: vernetztes Polyethylen (XLPE), sonnenlicht- und feuchtigkeitsbeständig, flammhemmend. Geeignet für unterirdisch verlegte Leitungen und Kabelkanäle.
  • Isolierung (Mantel): thermoplastisch, sonnenlichtbeständig, schwer entflammbar, wasserabweisend.
  • Mindestaußendurchmesser des Kabels mit Isolierung – 5,2 mm (2,05 Zoll).
  • Mindestleiterquerschnitt – 4 mm² (12 AWG).

SoliTek empfiehlt Installateuren, nur sonnenlichtbeständige Kabel zu verwenden, die für die Gleichstromverkabelung (DC) in PV-Systemen geeignet sind. Kabel sollten so an der Montagestruktur befestigt werden, dass eine mechanische Beschädigung des Kabels und/oder des Moduls vermieden wird. Belasten Sie die Kabel nicht. Verwenden Sie zur Befestigung geeignete Mittel, wie z. B. sonnenlichtbeständige Kabelbinder und/oder Kabelführungsklammern. Obwohl die Kabel sonnenlichtbeständig und wasserdicht sind, vermeiden Sie nach Möglichkeit direkte Sonneneinstrahlung und Eintauchen der Kabel in Wasser.
Die Standardlänge der Kabel von den Anschlussdosen beträgt 1,2 m (47,24 Zoll). Es ist vorgesehen, dass zwei Panels im System miteinander verbunden werden.

ERDUNG

  • Module grounding must be done in accordance with the electrical design and construction specifications, procedures, regulations and other special grounding requirements applicable to the installation sites. If grounding is needed, it should be done accordingly:

Framed type modules grounding
Mit einer Erdungsmarkierung am Rahmen gekennzeichnete Löcher dürfen nur zur Erdung verwendet werden. Bohren Sie keine zusätzlichen Erdungslöcher am Modulrahmen.
The grounding conductor or strap may be copper, copper alloy, or any other material acceptable foruse as an electrical conductor in accordance with local electric codes and regulations.
Der Erdungsleiter muss dann über eine geeignete Erdungselektrode eine Verbindung zur Erde herstellen.
A bolted connection is required; it incorporates:

  • Eine Schraubengröße von M4.
  • Eine Zahnscheibe unter dem Schraubenkopf oder eine gezahnte Schraube muss nichtleitende Beschichtungen wie eloxierte Rahmen durchdringen.
  • Eine Befestigungsmutter passend für M4-Schrauben.
  • Sämtliche Hardware muss aus Nichteisenmetall, Edelstahl der Serie 300 oder entsprechend korrosionsgeschützt sein.
  • Das empfohlene Drehmoment zum Sichern der Mutter beträgt 2 Nm ÷ 2.2 Nm (1,48 ÷ 1,62 ft-lb).
  • Der Erdungsbolzen muss durch alle Verbindungselemente gehen.

SoliTek-SOLID-Series-Solar-Modules-FIG-1

  • Geräte, die für die Erdung von Metallrahmen von PV-Modulen aufgeführt und gekennzeichnet sind, dürfen die freiliegenden Metallrahmen des Moduls an geerdeten Montagestrukturen erden.
  • In any case the grounding screws or other parts have to be used separately from the mounting parts of the module.
  • Alternate grounding options built through the mounting system are acceptable as long as they have been IEC and UL approved.
  • Grounding resistance of the grounding structure shall be reached according to local regulations, Eurocodes, or other legal normative references.

Frameless type modules grounding

  • Due to that modules are without frame, grounding is not forseen. Other PV plant equipment should be grounded according to the local and national electrical codes.

STECKVERBINDER

  • Connectors for SoliTek PV panels are Stäubli MC4-Evo 2. Keep connectors dry and clean and ensure that connector caps are hand-tight before connecting the modules.
  • Versuchen Sie nicht, eine elektrische Verbindung mit nassen, verschmutzten oder anderweitig fehlerhaften Anschlüssen herzustellen.
  • Vermeiden Sie Sonneneinstrahlung und das Eintauchen der Steckverbinder in Wasser. Vermeiden Sie, dass die Steckverbinder auf dem Boden oder der Dachfläche aufliegen.
  • Do not disconnect under load. Faulty connections can result in arcs and electrical shock.
  • Überprüfen Sie, ob alle elektrischen Anschlüsse fest sitzen. Stellen Sie sicher, dass alle Verriegelungsstecker vollständig eingerastet und verriegelt sind.

BYPASS-DIODEN

The PV module’s junction box contains 3 bypass diodes (one in each part of split junction box; Schottky type) connected in parallel with the PV cell strings. In the case of partial shading (hot-spot effect), the diodes bypass the current generated by the non-shaded cells, therebylimiting module heating and performance losses.
Bypass-Dioden sind keine Überstromschutzeinrichtungen. Bypass-Dioden leiten bei Teilverschattung Strom von den Zellsträngen ab. Die Eigenschaften dieser Dioden:

  • BandtagE-Bewertung – 50 V.
  • Nennstrom – 25 A.

BRANDKLASSE

  • SoliTek SOLID Bifacial- und Blackstar-Module wurden durch den IEC-Brandtest zugelassen und erreichten die Entflammbarkeitsklasse A. Der Brandtest wurde bei einer Neigung von 127 mm (5 Zoll) pro 300 mm (11,81 Zoll) durchgeführt, wie in Punkt A.2.5 von IEC 61730-2 vorgeschrieben.
  • SoliTek SOLID Bifacial has fire rating of 28 according to UL1703-2 standard. SoliTek Blackstar has fire rating of 29 according to UL1703-2 standard.

Mechanische Montage

  • The mechanical loads described in this manual are the test loads.
  • For calculating the equivalent maximum design loads, a safety factor of 1.5 (Design load×1.5 safety factor=Mechanical test load) needs to be considered in compliance with the requirements of the local laws and regulations.

ALLGEMEINE ANFORDERUNGEN

  • Modules can be mounted in landscape or portrait orientation. For the bifacial modules, in order to get notable bifacial gain, the distance between the bottom of the modules and the roof or ground surface shall be at least 0,8 m (31,50 inch).
  • Also, the bifacial gain increases significantly if modules are installed above white, light-reflecting surfaces (under surfaces with high albedo value).
  • If the mounting rails are installed across the module, the bifaciality effect will be lower due to back-side cells shading.
  • Bitte beachten Sie die dem Montagesystem beiliegenden Sicherheitsvorschriften und Montagehinweise. Für weitere Informationen wenden Sie sich bei Bedarf bitte direkt an den Anbieter.
  • The modules must be safely set onto the mounting rail.
  • The whole rail supporting the photovoltaic system must be strong enough to resist potential mechanical pressures caused either by wind or snow, in accordance with local, regional and state safety (and other associated) standards.
  • The mounting system shall be tested and inspected by a third-party testing institution with static mechanical analysis capacity in accordance with local national standards or international standards.
  • Before installing modules on a roof, ensure that the roof construction is suitable.
  • In addition, any roof penetration required to mount the modules must be properly sealed to prevent leaks.
  • Stellen Sie sicher, dass sich die Montageschiene bei einer Ausdehnung infolge Wärmeausdehnung nicht verformt und die Module dadurch nicht beeinträchtigt werden.
  • The module can appear thermal expansion and cold contraction; thus, the interval between two adjoining modules shall be no lesser than 10 mm (0,39 inch).
  • Versuchen Sie nicht, Löcher in die Glasoberfläche und die Rahmen der Module zu bohren, da dadurch die Garantie erlischt.
  • The mounting method must not result in the direct contact of dissimilar metals with the aluminum frame of the modules that will result in galvanic corrosion.

Die Befestigungselemente müssen aus langlebigen, korrosionsbeständigen und UV-beständigen Materialien bestehen (empfohlen werden Edelstahl- und eloxierte Aluminiumelemente).

MONTAGE MIT CLAMPS

  • Verwenden Sie mindestens 4 Laminatbödenamps zur Befestigung von Modulen auf den Tragschienen. Module Klamps Metallteile sollten nicht mit dem Front- oder Rückglas in Berührung kommen. Bei der Wahl dieser Art von Klamp-Montagemethode, verwenden Sie mindestens vier clamps auf jedem Modul; zwei clamps sollten an jeder langen Seite angebracht werden. Je nach örtlicher Wind- und Schneelast, zusätzlich Klamps können erforderlich sein, um sicherzustellen, dass Module die Last tragen können.
  • ClampDas Anzugsdrehmoment sollte mindestens 15 Nm (11,06 ft-lb) betragen, jedoch nicht größer als 20 Nm (14,75 ft-lb). Normalerweise werden 15 Nm (11,06 ft-lb) erreicht, wenn zwei Aluminiumprofiles berühren sich nicht. Bei der Hochformatmontage eines Moduls auf einem Schrägdach mit einer Neigung von >45° ist ein zusätzlicher Haken an der Unterseite des Moduls erforderlich.

SoliTek-SOLID-Series-Solar-Modules-FIG-2 SoliTek-SOLID-Series-Solar-Modules-FIG-3

SOLID Black, Semi-clear, Satin, Agro Frameless

Mit Querschienen

SoliTek-SOLID-Series-Solar-Modules-FIG-4 SoliTek-SOLID-Series-Solar-Modules-FIG-5SoliTek-SOLID-Series-Solar-Modules-FIG-6

BLACKSTAR, SOLID Black 35(40) mm, SOLID Semi-clear 35(40) mm, SOLID Satin 35(40) mm, SOLID Agro 35(40) mm, Magnus Framed mounting

  • Bei der Auswahl dieser Art von clamp-Montagemethode, verwenden Sie mindestens vier clamps auf jedem Modul; zwei clamps sollten auf jeder Seite des Moduls angebracht werden. Module clamps dürfen nicht mit der Frontscheibe in Berührung kommen und den Rahmen nicht verformen.
  • Vermeiden Sie unbedingt Schatteneffekte auf den Solarzellen durch die Modulschichtamps.
  • The module frame is not to be modified under any circumstances. Do not to block the drain hole of the frame.
  • Die Länge von Klamp should be at least 30 mm (1,18 inch).
  • Das Clamp muss den Modulrahmen um mindestens 5 mm (0,2 Zoll), jedoch nicht mehr als 10 mm (0,4 Zoll) überlappen.

Mit Querschienen

SoliTek-SOLID-Series-Solar-Modules-FIG-7 SoliTek-SOLID-Series-Solar-Modules-FIG-8 SoliTek-SOLID-Series-Solar-Modules-FIG-9

Ohne Querschienen oder Schienen stehen senkrecht zum Längsseitenrahmen

SoliTek-SOLID-Series-Solar-Modules-FIG-10 SoliTek-SOLID-Series-Solar-Modules-FIG-11

Mit Einschubsystem

SoliTek-SOLID-Series-Solar-Modules-FIG-12

Befestigung mit Bolzen

  • Das Modul muss mit vier M8-Edelstahlschrauben durch die angegebenen Befestigungslöcher an den Querträgern befestigt und gestützt werden. Drehmoment an der Klemmeamp bolt has to be in range of 8÷10 Nm (5,9÷7,38 ft-lb). The transversal bars positioning is shown in Figure 3.
  • If additional mounting points are required, depending on the local wind and snow loads, then a mounting solution with clampHardware muss ausgewählt werden.

SoliTek-SOLID-Series-Solar-Modules-FIG-13

  • Mounting with bolts can be done only through dedicated predrilled holes in the frame.
  • Das Bohren neuer Löcher ist verboten und führt zum Erlöschen der Garantie.

SoliTek-SOLID-Series-Solar-Modules-FIG-14 SoliTek-SOLID-Series-Solar-Modules-FIG-15

POSITION DER ANSCHLUSSDOSE

  • Den Abstand zwischen Anschlussdose und Modulrand sowie weitere Maße zur Position und Fläche der Anschlussdose entnehmen Sie bitte den untenstehenden Abbildungen.

SoliTek-SOLID-Series-Solar-Modules-FIG-16

WARTUNG

  • Um eine optimale Modulleistung sicherzustellen, empfiehlt SoliTek Folgendes:
  • Bei Bedarf kann die Glasfront des Moduls mit Wasser und einem weichen Schwamm oder Tuch gereinigt werden.
  • Um hartnäckigere Flecken zu entfernen, kann ein mildes, nicht scheuerndes Reinigungsmittel verwendet werden.
  • Überprüfen Sie regelmäßig die elektrischen und mechanischen Verbindungen und stellen Sie sicher, dass sie sauber, sicher, vollständig und sicher sind.
  • Im Falle eines Problems wenden Sie sich an eine lizenzierte/qualifizierte Person.

Spezifikationen

Parameter \ Modell SCHWARZER STERN B.96 SOLID Black (Semi-Clear) B.96 35(40) mm SCHWARZER STERN Satin B.96 MAGNUS B.108
Testbedingungen STC STC STC STC
Nennleistung 455 Watt 455 Watt 445 Watt 510 Watt
Elektrische Daten @STC
Maximale Leistung (Pmax), W 455 455 445 510
Bandtage bei maximaler Leistung (Vmpp), V 29,71 29,71 29,40 33,34
Strom bei maximaler Leistung (Impp), A 15,31 15,31 15,14 15,30
Offener Kreislauf Voltage (Voc), V 34,82 34,82 34,40 39,06
Kurzschlussstrom (Isc), A 15,97 15,97 15,79 15,95
Thermische Daten
Betriebstemperaturbereich -40 °C bis 85 °C (-40 °F bis 185 °F) -40 °C bis 85 °C (-40 °F bis 185 °F) -40 °C bis 85 °C (-40 °F bis 185 °F) -40 °C bis 85 °C (-40 °F bis 185 °F)
Temperaturkoeffizient von Pmax -0,362 %/°C (°F) -0,362 %/°C (°F) -0,362 %/°C (°F) -0,362 %/°C (°F)
Temperaturkoeffizient von Voc -0,265 %/°C (°F) -0,265 %/°C (°F) -0,265 %/°C (°F) -0,265 %/°C (°F)
Temperaturkoeffizient von Isc +0,036% /° C (°F) +0,036% /° C (°F) +0,036% /° C (°F) +0,036% /° C (°F)
Daten zu Größe und Gewicht
Länge 1762 mm 1762 mm 1762 mm 1961 mm
Breite 1134 mm 1134 mm 1134 mm 1134 mm
Dicke 30 mm 35(40) mm 30 mm 30 mm
Gewicht 25,5 kg 35 (36) kg 25,5 kg 28,5 kg
Montagemethode
Reference to the chapter 3.3 3.3 3.3 3.3
Andere
Maximaler Rückstrom, A 30
Fire    class, IEC 61730/UL 61730 A/Typ II
Maximale Systemlautstärketage, v 1500

Table 9. Electrical and mechanical parameters table.

Parameter \ Modell SOLIDE Semi- clear B.96 SOLID Black B.96 SOLIDE Satin B.96 SOLIDE Agro B.64
Testbedingungen STC STC STC STC
Nennleistung 455 Watt 455 Watt 445 Watt 300 Watt
Elektrische Daten @STC
Maximale Leistung (Pmax), W 455 455 445 300
Bandtage bei maximaler Leistung (Vmpp), V 29,71 29,71 29,40 19,60
Strom bei maximaler Leistung (Impp), A 15,31 15,31 15,14 15,31
Offener Kreislauf Voltage (Voc), V 34,82 34,82 34,40 22,76
Kurzschlussstrom (Isc), A 15,97 15,97 15,79 15,97
Thermische Daten
Betriebstemperaturbereich -40 °C bis 85 °C (-40 °F bis 185 °F) -40 °C bis 85 °C (-40 °F bis 185 °F) -40 °C bis 85 °C (-40 °F bis 185 °F) -40 °C bis 85 °C (-40 °F bis 185 °F)
Temperaturkoeffizient von Pmax -0,30 %/°C (°F) -0,30 %/°C (°F) -0,30 %/°C (°F) -0,30 %/°C (°F)
Temperaturkoeffizient von Voc -0,25 %/°C (°F) -0,25 %/°C (°F) -0,25 %/°C (°F) -0,25 %/°C (°F)
Temperaturkoeffizient von Isc +0,045% /° C (°F) +0,045% /° C (°F) +0,045% /° C (°F) +0,045% /° C (°F)
Daten zu Größe und Gewicht
Länge 1772 ± 2 mm 1772 ± 2 mm 1772 ± 2 mm 1772 ± 2 mm
Breite 1144 ± 2 1144 ± 2 1144 ± 2 mm 1144 ± 2 mm
Dicke 7,2 mm 7,2 mm 7,2 mm 7,2 mm
Gewicht 33 kg 33 kg 33 kg 33 kg
Montagemethode
Reference to the chapter 3.2 3.2 3.2 3.2
Andere
Maximaler Rückstrom, A 30
Fire    class, IEC 61730/UL 61730 A/Typ II
Maximale Systemlautstärketage, v 1500

Table 10. Electrical and mechanical parameters table.

Parameter \ Modell SOLID Satin B.96 35 mm SOLID Satin B. 96 40 mm SOLID AgroB.64 35 mm SOLID AgroB.64 40 mm
Testbedingungen STC STC STC STC
Nennleistung 445 Watt 445 Watt 300 Watt 300 Watt
Elektrische Daten @STC
Maximale Leistung (Pmax), W 445 445 300 300
Bandtage bei maximaler Leistung (Vmpp), V 29,40 29,40 19,60 19,60
Strom bei maximaler Leistung (Impp), A 15,14 15,14 15,31 15,31
Offener Kreislauf Voltage (Voc), V 34,40 34,40 22,78 22,78
Kurzschlussstrom (Isc), A 15,79 15,79 15,97 15,97
Thermische Daten
Betriebstemperaturbereich -40 °C bis 85 °C (-40 °F bis 185 °F) -40 °C bis 85 °C (-40 °F bis 185 °F) -40 °C bis 85 °C (-40 °F bis 185 °F) -40 °C bis 85 °C (-40 °F bis 185 °F)
Temperaturkoeffizient von Pmax -0,362 %/°C (°F) -0,362 %/°C (°F) -0,30 %/°C (°F) -0,30 %/°C (°F)
Temperaturkoeffizient von Voc -0,265 %/°C (°F) -0,265 %/°C (°F) -0,25 %/°C (°F) -0,25 %/°C (°F)
Temperaturkoeffizient von Isc +0,036% /° C (°F) +0,036% /° C (°F) +0,045% /° C (°F) +0,045% /° C (°F)
Daten zu Größe und Gewicht
Länge 1762 mm 1762 mm 1762 mm 1762 mm
Breite 1134 mm 1134 mm 1134 mm 1134 mm
Dicke 35 mm 40 mm 35 mm 40 mm
Gewicht 35 kg 36 kg 35 kg 36 kg
Montagemethode
Reference to the chapter 3.3
Andere
Maximaler Rückstrom, A 30
Fire    class, IEC 61730/UL 61730 A/Typ II
Maximale Systemlautstärketage, v 1500

Table 11.Electrical and mechanical parameters table.

  • The electrical characteristics are within of the indicated values of ISC (φISC) ±3%, VOC (ϕVOC) ±3,5% and PMPP (ϕPmax) ±5%, under Standard Test Conditions (STC) (irradiance of 1000 W/m²,AM 1.5 spectrum, and a cell temperature of 25°C / 77°F)
  • Alle SoliTek SOLID PV-Module entsprechen der elektrischen Schutzklasse II.

Haftungsausschluss

  • Da es für SoliTek unmöglich ist, die Installation, den Betrieb, die Anwendung und die Wartung der Photovoltaikanlage gemäß dieser Anleitung zu kontrollieren, übernimmt SoliTek keine Verantwortung und lehnt ausdrücklich die Haftung für Verluste, Schäden oder Kosten ab, die aus der Installation, dem Betrieb, der Anwendung oder der Wartung entstehen oder in irgendeiner Weise damit in Zusammenhang stehen.
  • SoliTek will not take any responsibility for any possible violation of patent rights and third-party rights that are related to the application of the solar energy system. No permission of patents is given through implication.
  • The information of this instruction is from the knowledge and experiences of SoliTek. However, the instructions and suggestions of this instruction do not make an external or internal of guarantee. SoliTek reserves the right to revise this instruction, products and all the information about products without prior notification to customers.

www.solitek.eu

Häufig gestellte Fragen

  • Q: What should I do before installing the PV modules?
    • A: Read this entire guide, understand all instructions, and ensure compliance with all local, state, and federal regulations. Consult a certified building specialist for the structural integrity of the dwelling.
  • Q: Can I install the PV modules myself without professional training?
    • A: This documentation is not a complete installation manual for personnel not specifically trained in PV-modules. It serves as a general but strictly mandatory reference for the installer. Professional installation is highly recommended.
  • Q: What happens if I don’t follow the instructions in this guide?
    • A: Failure to follow instructions may damage system components, endanger personnel, damage property, or invalidate the panel warranty.
  • Q: Is it safe to work on a rooftop during installation?
    • A: Do not attempt to work on a rooftop until safety precautions have been identified and taken, including fall protection measures, ladders or stairways, and personal protective equipment (PPE). Avoid adverse conditions like strong winds or wet/frosted roofs.
  • Q: How should I store the PV modules before installation?
    • A: Store pallets in a cool and dry location until the PV modules are ready to be unpackaged. Do not exceed the maximum stacking height indicated on the packaging.

Dokumente / Ressourcen

PDF thumbnailSOLID Series Solar Modules
Installation Guide · SOLID Series Solar Modules, SOLID Series, Solar Modules, Modules

Verweise

Eine Frage stellen

Use this section to ask about setup, compatibility, troubleshooting, or anything missing from this manual.

Eine Frage stellen

Ask about setup, compatibility, troubleshooting, or anything missing from this manual. Name and email are optional.